Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  membrana z polichlorku winylu
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Novel polymeric membrane (PME) and coated graphite (CGE) silver-selective electrodes based on a calix[4]resorcareneoctamethyl ester has been prepared. The electrodes revealed Nemstian behaviour over a wide Ag+ion concentration range (1.0 x 10'5-1.0 * 10 ' mol L"' for PME and 1.0 * 1.0-10(-7) x 10(-1) mol L(-1) for CGE) with very low detection limits (4.7 x K)(-6) mol L(-1) for PME and 8.5 x 10(-8) mol L(-1) for CGE). They occurred to be very selective towards Ag+ even in the presence of other numerous cations. Their responses were independent of pH within the range of 4-9. The electrodes can be used for at least 3 months without any considerable potential deviations. They served as indicator electrodes in poten-tiometric titration of silver ion.
PL
Spreparowano nowe, selektywne w stosunku do srebra elektrody z polimerową membraną (PME) zawierające ester kaliks[4]rezorkarenooktametylowy. W jednym rozwiązaniu konstrukcyjnym matrycę PCV nakładano na grafit. Elektrody spełniają prawo Nersta w szerokim zakresie stężenia jonów Ag+(l,O x 10(-5)-l,0x 10(-1) 'mol L(-1) w przypadku PME i 1,0 x 10(-7)-1,0 x 10(-1) w przypadku CGE) przy bardzo niskiej granicy wykrywalności (4,7 x l 0(-6) mol L(-1) w przypadku PME oraz 8,5 x l 0(-8) mol L(-1) w przypadku CGE). Wykazują bardzo dobrą selektywność w stosunku do jonów srebra nawet w obecności wielu innych kationów. Ich odpowiedzi nie zależą od wartości pH w granicach 4-9. Elektrody mogą być używane co najmniej przez 3 miesiące bez widocznych zmian potencjału. Stosowano je jako wskaźnik w potencjometrycznym miareczkowaniu jonów srebra.
EN
A lead (II) ion-selective poly(vinyl chloride) membrane electrode containing 2,2'-dithiodi-benzoic acid as a carrier was prepared. The electrode exhibits a Nernstian response for lead(II) cations over a wide Pb2+ concentration range (5.0 x 10(-6) x 10(-2) mol L(-1) with a slope of 29.9 š 0.3 mV decade(-1). Designed electrode exhibits a fast (time shorter than 10 s) and stable potential response for at least 3 months. Its selectivity to Pb2+ in the presence of alkali, alkaline earth and some transition and heavy metal ions is satisfactory in the pH range of 4-6.5. The studied sensor served as an indicator electrode in the potentiometric titration of lead ions, and also for determination of anions such as sulfides, chromałeś and carbonates.
PL
Spreparowano elektrodę jonoselektywną zawierającą kwas 2,2'-ditiodibenzoesowy w membranie z polichlorku winylu. Otrzymano odpowiedź nernstowską w stosunku do Pb2+ w zakresie stężeń 5 x 10(-6)-1 x 10(-2) mol (-1). Elektroda miała czas odpowiedzi poniżej l O s i mogła być używana przynajmniej przez miesiąc. Selektywność wobec Pb(2+) w obecności metali alkalicznych i ziem rzadkich oraz niektórych metali ciężkich i przejściowych była dobra. Przedział pH pracy elektrody określono jako 4-6.5. Opracowaną elektrodę użyto w potencjometrycznym miareczkowaniu Pb2+ oraz do oznaczania siarczków, chromianów i węglanów.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.