Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  medium stałe
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The adsorption heat pump with silica gel adsorbent and water adsorbate was discussed. Authors focus on conventional single stage cycle adsorption heat pump. The design of the adsorber/desorber considered element is the tube with deposited silica gel bed. The analytical model was created to describe the temperature and concentration changes in the adsorber/desorber and consequently to describe the performance of the adsorption heat pump. In the presented paper a comparison of the results of the basic and the expanded analytical model was performed. The calculation results from the analysis were presented in tables and figures.
PL
Przedstawiono metodę oznaczania olejów za pomocą spektrofotometrii absorpcyjnej w nadfiolecie. Przeprowadzono badania mające na celu dobranie stałego środka sorpcyjnego charakteryzującego się wysokim współczynnikiem odzysku tych substancji. W tym celu zastosowano obliczenia statystyczne stosowane w metrologii chemicznej pozwalające na stwierdzenie, że opracowana metoda badawcza charakteryzuje się dobrą precyzją. Procedura analityczna charakteryzuje się również odpowiednią dokładnością, o czym świadczą małe wartości względnego błędu przypadkowego wartości średniej U'A. Wyznaczone wartości współczynników odzysku są bliskie wartości 100%, a wartości odchylenia standardowego i współczynników zmienności świadczą o precyzji metody. Względne błędy przypadkowe wartości średniej U'A współczynników odzysku są mniejsze, niż 10%, co świadczy o przydatności metody do tego typu oznaczeń.
EN
At present, there are no testing methods in the country which would permit to evaluate protective gloves, regarding their resistance to glue/adhesive permeability. At present, the efficacy of gloves' protection levels against chemical substances is assessed experimentally, in accordance with a normalized procedure, described in PN-EN 374-3:2005 standard. Taking into consideration the fact that hydrocarbons are the main oil components, neither gas nor water-based collecting medium can be used in a permeability chamber. In this situation, a selection of an appropriate solid medium would seem an optimal solution. However, neither accurate testing procedures nor result calculation methods have been designed and adapted for this particular purpose. The goal of the study was an evaluation of the analytical parameters of the designed test procedure and the definition of the attributes of the obtained statistical results. The scope of the study included a selection of solid collecting media and of reference oils; an optimization of reference oil sorption process on the selected solid medium, sample extraction methods and a quantitative estimation of the relation expressed by the recovery index. The results indicate that the designed method is appropriately precise and accurate, which is evidenced by the small values of the relative chance error of the U'A mean value. The determined values of recovery indices are close to 100%, while SD and variation index values are indicative of the method's precision. Relative random errors of the U'A mean value of recovery indices are < 10%, which is the best evidence for the usefulness of the method for such measurements.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.