Ograniczanie wyników
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  mechanism of zone spreading
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Separation of rare earth elements (REE) by ion chromatography employing three different α-hydroxyacids i.e. lactic (HLac), mandelic (HMand) and a-hydroxyisobutyric (a-Hlac) was studied using Dionex Ion Pac CS3 + CG3 column and Arsenazo III as a colour forming reagent. Special attention was paid to the effect of temperature on selectivity of separation and on column performance. Yttrium, which normally coelutes with dysprosium could be partly separated when using a-HIBA at elevated temperatures (65-75°C). Scandium, which at room temperature was eluted well ahead of the lanthanides (in all three systems investigated), at elevated temperatures when using HLac and especially HMand gradually moved into the region where lanthanides were eluted. Interestingly, plate heights calculated from elution curves of yttrium were smaller, and those of scandium higher, than the corresponding plate heights of the lanthanides. Significant contribution of the longitudinal diffusion in the stationary phase to the total zone spreading was observed. Comparison of the elution curves of all REE employing the same isocratic-gradient elution mode for the three acids at two different temperatures is presented.
PL
Wykonano badania wpływu rodzaju a-hydroksykwasu stosowanego jako eluent na rozdzielanie kationów pierwiastków ziem rzadkich (REE). Do rozdzielań REE zastosowano trzy a-hydroksykwasy: mlekowy (HLac), migdałowy (HMand) i a-hydroksyizomasłowy (a-HIBA). Badania przeprowadzono z wykorzystaniem wysokosprawnej kolumny kationo-wymiennej typu Dionex Ion Pac CS3 + CG3 i Arsenazo III jako barwnego odczynnika kompleksującego. Zbadano również wpływ temperatury na zmiany selektywności kationitu wobec rozdzielanych kationów REE oraz zmiany sprawności kolumny chromatograficznej.
EN
The effect of column temperature on retention of alkali metal and alkaline earth metal cations, as well as some amines, has been studied using three commercially available cation-exchange columns of Dionex Ion Pac type (CS10, CS12 and CS12A). Each column was packed with the cation-exchange resin containing different functional groups: strongly acidic sulphonic acid groups in Ion Pac CS10, weakly acidic carboxylic acid groups in Ion Pac CS12, and a mixture of weakly acidic carboxylic acid and phosphonic acid groups in Ion Pac CS12A column. The temperature was being changed from 10°C up to 60°C, which caused selectivity changes of the cation exchangers towards the analyzed cations, as well as the changes of column efficiencies. The changes of thermodynamic functions (free energy, enthalpy and entropy) for the studied cation-exchange processes were calculated. The comparison of the temperature effect on the ion-exchange behaviour of several ions on three cation-exchange columns with pellicular-type resin beds has been made. It has been noticed, that in some cases the lowering of the column temperature down to 10°C was more advantageous to achieve complete and rapid separation of some cations than the increase of the column temperature. It has been found that in the case of ions of high retention factors the longitudinal diffusion within the resin phase may significantly contribute to the total plate height.
PL
W niniejszej pracy zbadano wpływ temperatury na rozdzielanie kationów metali alkalicznych i ziem alkalicznych oraz niektórych amin na trzech wysokosprawnych kolumnach kationo-wymiennych typu Dionex Ion Pac (CS10, CS12 i CS12A). Każda z kolumn była wypełniona kationitem zawierającym inny rodzaj grup funkcyjnych: silnie kwasowe grupy sulfonowe (kolumna CS10), słabo kwasowe grupy karboksylowe (kolumna CS12) oraz mieszaniną słabo kwasowych grup karboksylowych i fosfonowych (kolumna CS12A). Zmiany temperatury pracy kolumn w zakresie od 10°C do 60°C wpływały na selektywność badanych kationitów w stosunku do rozdzielanych kationów, jak również na sprawność kolumn. Dla każdej z badanych kolumn i każdego z analizowanych kationów obliczono zmiany entalpii, entropii i energii swobodnej reakcji kationowymiennych. Porównano efekty temperaturowe dla trzech badanych kolumn. W przypadkach niektórych par kationów obniżenie temperatury do 10°C sprzyjało ich lepszemu rozdzieleniu. Wykazano również, że w przypadku kationów o wysokich współczynnikach retencji dyfuzja podłużna w fazie jonitu może wpływać w znaczący sposób na wysokość półki teoretycznej kolumny.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.