Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  measurand reconstruction
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Sensors signal processing under influence of environmental disturbances
EN
The article presents methods of counteracting the influence of environmental conditions on the measurement. Graphical representations of these methods have been proposed. Environmental disturbances occur in the measurement of industrial and environmental processes. It was assumed the presence of cross-sensitivity to one physical quantity (temperature) in an intelligent sensor with a multidimensional output. Correction of errors related to the influence of disturbances is done using signal processing methods.
PL
W artykule przedstawiono metody przeciwdziałania wpływowi zmian warunków fizykochemicznych na wynik pomiaru. Zaproponowano graficzną reprezentację omawianych metod. Zmiana warunków występuje w pomiarach wielu procesów przemysłowych oraz środowiskowych. Założono występowanie czułości skrośnej na jedną wielkość fizyczną (temperaturę) w czujniku inteligentnym o wyjściu wielowymiarowym. Korekcja błędów związanych z wpływem wielkości zakłócających odbywa się za pomocą metod przetwarzania sygnałów.
2
Content available remote Wyznaczanie stężeń gazów dla matrycowych nieselektywnych czujników gazów
PL
Opisano i porównano cztery metody wyznaczania końcowego wyniku pomiaru przy wykorzystaniu w torze pomiarowym czujników nieliniowych i jednocześnie nieselektywnych, (wrażliwych na wielkości dodatkowe). Jako modele charakterystyk odtwarzania oraz modele wpływu wielkości dodatkowych przyjęto wielomiany maksymalnie 2 stopnia. Skuteczność proponowanych metod sprawdzono przy wykorzystaniu danych eksperymentalnych uzyskanych dla matrycowego przetwornika stężeń gazów w mieszaninach, w którym wykorzystano czujniki metanu TGS2611 i dwutlenku węgla TGS5042 oraz czujniki wilgotności i temperatury.
EN
In spite of progress in theory and technology of sensors, especially gas sensors, there is still difficult to obtain good metrological properties of them. The most important disadvantages are nonlinearity of transfer curve and quite big sensitivity for additional quantities, mainly temperature, humidity but also other gases in case of gas sensors (i.e. non-selectivity). To apply such sensors in gas concentration measurement transducers some effective methods of measurand reconstruction are required. There are described and compared four numerical methods in this article. The general assumption was that as well the main inverse transfer characteristic as the influence characteristics are described by the polynomials of order not higher than two. The first method does not include correction of additional quantities influence and was included only to compare with other methods result. Efficiency of proposed methods was tested using set of data obtain experimentally for two kind of multi-component (matrix) gas sensors based on Taguchi sensors and integrated temperature and humidity sensor. In conclusion was stated that it is possible to reach quite good efficiency of correction when a multiplicative inverse model of sensor is used, described by 18 coefficient (the 3-rd method). In this case the calibration procedure is rather laborious, but a procedure of coefficient determination and correction procedure are quite simple. Efficiency of the 4-th method is very high, but determination of inverse model coefficients is very complicated.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.