The paper presents the possibility of using non-destructive testing with active thermography to the location of reinforcement in concrete elements. Four reinforced concrete elements in the form of beams with dimensions of 24 x 24 x 200 cm was researched. The beams had the main reinforcement with diameters sequentially: 12 mm, 16 mm, 20 mm and 25 mm. Stirrups with a diameter of 6 mm were placed every 20 cm. Lagging for the main reinforcement of test surface was 26 mm. Reinforced concrete elements were heated with an infrared lamp and thermal images were recorded periodically at intervals of 1 min. Preliminary studies have shown that detection of reinforcement in concrete elements using active thermography is possible. The rebar was visible on the thermograms from the start of the cool down phase for about 20 min after. The study contains a description of the test stand, and the tests performed. The paper also highlighted the problems encountered on the implementation of research and prospect of development active thermography as a non-destructive testing.
EN
The paper describes the problem of building envelope investigation with active thermography. Mainly emphasized is its application to detect different material of wall inclusions. Examples of active thermography application and description of experimental investigation has been shown on a model envelope, with inclusion of significantly different thermal conductivity and heat capacity materials; XPS polystyrene, steel and granite. Thermograms received for every kind of inclusion have been compared and analyzed. Finally, the summary and conclusion have been shown along with the prospects of development and practical application of this kind of investigation in construction.
PL
Artykuł porusza problem wykonywania badań przegród budowlanych za pomocą termografii aktywnej. Podkreślono w nim możliwość detekcji różnych wtrąceń materiałowych w przegrodzie. Praca przedstawia wykonane badanie doświadczalne na modelu przegrody, w którym zamodelowano wtrącenia z materiałów o znacznie różniącym się współczynniku przewodzenia ciepła tj. styropian XPS oraz stal. Otrzymane termogramy porównano ze sobą i poddano analizie. W podsumowaniu przedstawiono wnioski wraz z perspektywami rozwoju badań i praktycznego zastosowania termografii aktywnej w budownictwie.