Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  mass flux
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The current article addresses the impacts of the pulsatile flow of Powell-Eyring nanofluid using Buongiorno’s model in a horizontal channel. It also describes the combined impacts of thermophoresis and Brownian motion. Blood is an example of a Powell-Eyring fluid. The Runge-Kutta (R-K) 4th-order method, along with the shooting technique, is used to determine solutions for velocity, temperature, and concentration. The impacts of different parameters, including an inclined magnetic field, chemical reaction, Lewis number, and heat source or sink parameter, are illustrated graphically. The mass flux distribution decreases due to an increase in the values of the Powell-Eyring fluid parameter.
EN
Forced convective heat and mass transfer flow of hydromagnetic, radiating and dissipative fluid over a porous nonlinear stretching sheet in the presence of non-uniform heat generation/absorption is investigated numerically. The system of nonlinear partial differential equations governing the physical problem is reduced to nonlinear ordinary differential equations by means of suitable similarity transformations and are solved numerically using Nachtsheim Swigert shooting iteration scheme together with fourth order Runge Kutta method. The effects of various physical parameters on velocity, temperature and concentration distributions are depicted graphically. The important findings of this study exhibited that the effect of non-uniform heat generation/absorption parameter and radiation parameter have significant role in controlling thermal boundary layer thickness and temperature. Numerical values of the skin friction coefficient, temperature and concentration at the wall are shown in a tabula form. A comparison is made with previously published data which results in good agreement.
EN
The article presents tests of the influence of the density of the mass flux of the densified material (5.29, 6.80, and 8.31 kg/m2•s) and the influence of the rotational speed of the matrix (280, 330, and 380 r•min-1) on the power consumption of the pellet mill and the quality of obtained pellets. The tests were carried out on a SS-2 stand with a working system of a pellet mill with a rotating matrix. On the basis of performed tests it was concluded that an increase in density of the mass flux of densified material and an increase in rotational speed of the matrix cause an increase in power consumption of the device and a reduction of the density and kinetic durability of obtained pellets.
PL
W artykule opisano badania wpływu gęstości strumienia masy zagęszczanego surowca (5,29 6,80 i 8,31 kg/m2•s) oraz wpływ prędkości obrotowej matrycy (280, 330 i 380 obr•min-1) na zapotrzebowanie granulatora na moc oraz jakość otrzymanego granulatu. Badania przeprowadzono na stanowisku SS-2 z układem roboczym granulatora z pierścieniowa obrotowa matryca. Na podstawie przeprowadzonych badan stwierdzono, że zwiększenie gęstości strumienia masy zagęszczanego materiału oraz zwiększenie prędkości obrotowej matrycy powoduje wzrost zapotrzebowania urządzenia na moc oraz spadek gęstości i wytrzymałości kinetycznej otrzymanego granulatu.
EN
Thermal radiation effects on unsteady flow past an oscillating semi-infinite isothermal vertical plate with uniform mass flux have been studied. The fluid considered here is a gray, absorbing-emitting radiation but non-scattering medium. The dimensionless governing equations are solved by an efficient, more accurate, and unconditionally stable and fast converging implicit scheme. The effect of velocity and temperature for different parameters like thermal radiation, Schmidt number, thermal Grashof number and mass Grashof number are studied. It is observed that the velocity decreases in the presence of thermal radiation.
EN
Thermal radiation effects on unsteady flow of a viscous incompressible fluid past an exponentially accelerated infinite isothermal vertical plate with uniform mass flux has been studied. The fluid considered here is a gray, absorbing-emitting radiation but a non-scattering medium. The plate temperature is raised to Tw and the concentration level near the plate is also made to be at a constant rate. An exact solution to the dimensionless governing equations has been obtained by the Laplace transform method, when the plate is exponentially accelerated with a velocity […] in its own plane. The velocity, temperature and concentration fields are studied for different physical parameters such as the thermal Grashof number, mass Grashof number, Schmidt number, a and time. It is observed that the velocity increases with increasing values of a or t.
EN
An exact solution of an unsteady flow past an uniformly accelerated infinite vertical plate with prescribed uniform heat and mass flux is analyzed. The temperature of the plate and concentration level near the plate are raised at a uniform rate. The dimensionless governing equations are tackled using the usual Laplace-transform technique. The velocity, temperature and concentration fields are studied for different physical parameters such as the Prandtl number, thermal Grashof number, mass Grashof number, Schmidt number and time. It is observed that the velocity increases with increasing values of the thermal Grashof number or mass Grashof number. It is also observed that the velocity increases with decreasing values of the Schmidt number.
EN
A finite difference solution of the transient natural convection flow of an incompressible viscous fluid past an impulsively started semi-infinite vertical plate with constant mass flux and variable surface temperature in the presence of thermal radiation is presented here. The velocity profiles are compared with the exact solution and are found to be in good agreement. The velocity, temperature and concentration profiles are shown graphically. It is observed that the velocity decreases with increasing values of radiation or the chemical reaction parameter. The local as well as average skin-friction, Nusselt number and Sherwood number are shown graphically.
PL
W opracowaniu przedstawiono wyniki pomiarów strumieni CO2 i H2O z powierzchni trawiastych w warunkach późnej wiosny (27-29 maja). Do pomiarów zastosowano automatyczny system pomiarowy składający się z anemometru sonicznego i analizatora gazowego CO2 i H2O. Do szacowania wartości strumieni wykorzystano bardzo dokładną metodę korelacyjną, która zakłada wyliczanie wartości strumieni bezpośrednio z definicji, bez konieczności stosowania współczynników empirycznych. W ten sposób możliwe jest badanie wymiany badanych gazów między podłożem a atmosferą. Pomiary wykazały istnienie wyraźnej dobowej zmienności strumieni dwutlenku węgla i pary wodnej. Strumień CO2 w ciągu dnia był ujemny (skierowany do powierzchni czynnej - pochłanianie dwutlenku węgla przez rośliny w procesach fotosyntezy) i osiągał maksymalne wartości rzędu -30 umol-m^—2s^—1 w godzinach południowych, natomiast w nocy zmieniał znak na dodatni (transport CO2 do atmosfery - uwalnianie dwutlenku węgla w procesach oddychania roślin) i sięgał wartości ok. 10 do 15 umol-m^—.2s^—.1. W badanym okresie w ciągu dnia strumień pary wodnej był dodatni (transport pary wodnej do atmosfery w wyniku parowania) i maksymalne wartości rzędu 0,1 g-m^—.2godz^—.1 (0,4 mm-m^-2godz^-1) osiągał w godzinach południowych. W godzinach nocnych strumień przyjmował wartości dużo niższe, bliskie zera
EN
This paper contains results of CO2 and H2O fluxes measurements from grass surface in the end of spring (27-29 of May). Automatic measurement system, consists in sonic anemometer and infra--red H2O and CO2 gas analyzer, was used. The values were estimates with use of the eddy correlation method, which assumes fluxes calculating direct from the definition, without necessity of application of empirical coefficients. In this way there is a possibility to measure H2O and CO2 exchange between surface and atmosphere. Measurements shows distinct diurnal variability of carbon dioxide and water vapor fluxes values. CO2 flux was negative during the day (directed downward to active surface - because of carbon dioxide absorption in photosynthesis processes) and reached maximum values about -30 umol-m^-2^s^-1 about noon, but during the night was positive (transport of CO2 to the atmosphere - in the consequence of plants respiration) and reached maximum values from 10 to 15 (umol-m^-2s^-1. Water vapor flux was positive during the day (evaporation) and reached maximum values about 0.1 gm^-2h^-1 (0.4 mm . m^-2h^-1) about noon, but as distinct from CO2 flux, during the night H2O flux reached lower values (near 0).
PL
Pomiar strumienia masy lub objętości cieczy w kanałach o dużym przekro-ju dotyczy np. sytuacji przepływu wody chłodzącej z chłodni kominowych do kondensatorów pary wodnej w blokach energetycznych elektrowni zawodowych. Stosowanie klasycznych metod pomiarowych w tym np. zwężek przekroju jest praktycznie niemożliwe. Również inne metody pomiaru tego strumienia, przykładowo za pomocą przepływomierzy ultradźwiękowych, nie spełniają wymogów metrologicznych. Autorzy do w/w pomiarów zastosowali dwie metody: sondy uśredniające ciśnienie dynamiczne oraz przepływomierze wykorzystujące siły bezwładności cieczy wynikające ze zmiany kierunku przepływu - tzw. przepływomierze kolanowe. W referacie opisane będą zasady realizacji pomiarów, własności metrologiczne przepływomierzy wraz z analizą niepewności pomiarów.
EN
Fluid mass flux and volumetric flow measurement in high section channels may concerns for instant cooling water flow from cooling tower to steam capacitor in power units of power plants. Use of classical measurements methods such orifice plates is practically impossible while the other ones, with use of ultrasonic flowmeter for instant, don't meet metrological requirements. For measurements described above, two methods have been used: dynamic pressure averaging probes and centrifugal-head flowmeters that make use of fluid interial forces resulting from change of direction flow. The measurements carrying out principles and metrological properties of flowmeters with measurement uncertainty analysis will be described in this paper.
10
Content available remote Sposoby rozszerzania użytecznego zakresu pracy sprężarki
PL
W pracy omówiono zasadnicze sposoby przesuwania linii statecznej pracy sprężarki w stronę mniejszych wartości strumienia masy. Przedstawiono pasywne metody zwiększania zapasu statecznej pracy sprężarek lotniczych silników turbinowych. Zaprezentowano kolejno następujące sposoby: przewężenie dyfuzora bezłopatkowego, zainstalowanie dyfuzora łopatkowego i rurkowego, zmianę kąta ustawienia kierownicy wlotowej, odsysanie i dodmuchiwanie czynnika na wlot, modyfikację kadłuba nad wirnikiem.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.