Mine acid drainage (MAD) is a primary environmental problem caused by mining activity. The main characteristics of MAD are extremely low pH level (1.5–4.0), as well as content of sulfate and a number of heavy metals and metalloids that can destroy vegetation, accelerate erotion, and disrupt land ecosystem balance. The objective of this research was to process MAD by improving pH level and lowering iron and manganese content in MAD by Lactobacillus casei and Dekkera bruxellensis mixed culture. MAD Neutralization test was conducted on SMSs media with MAD concentration variations of 10, 15, 20 and 25 (%;v/v), and contact time variations of 48, 96, 144, and 192 (hours). The MAD neutralization test by Lactobacillus casei and Dekkera bruxellensis mixed culture occurred best at 10% concentration (v/v) with contact time of 96 hours. The pH improvement reached up to 6.20 with iron metal efficiency removal at 32.47% and manganese metal up to 24.94%. MAD neutralization test revealed that the best contact time variation is at 96 hours. At this contact time, the pH level was increased to 6.17 with iron metal removal efficiency at 31.17% and manganese metal removal at 25.43%.
PL
W gospodarce komunalnej związanej z zaopatrzeniem ludności w wodę oraz w przemyśle przetwórstwa spożywczego podstawowym surowcem jest woda spełniająca wysokie wymagania jakościowe. Źródłem takich wód są wody podziemne, charakteryzujące się obecnością typowych dla nich zanieczyszczeń, takich jak związki żelaza, związki manganu i związki amonowe. Wszystkie te zanieczyszczenia muszą być redukowane z wody przeznaczonej na potrzeby technologiczne do jak najniższych zawartości.
EN
There is a need to implement high-efficiency solutions for groundwater treatment, especially in the context of manganese compounds removal. This study analyzed the impact of a water treatment plant modernization to a technology of fast contact filters with continuous bed rinsing. On the basis of basic indicators of water pollution, such as iron, manganese, turbidity, color, and nitrogen compounds, the raw water collected from the groundwater intake and the water treated after the filtration process were characterized. A comparison of the efficiency of water treatment installation before and after modernization indicated that there was a significant improvement in the quality of treated water, especially in terms of manganese removal.
EN
The recent climate condition and pollution problem related to surface water have led to water scarcity in Malaysia. Huge amount of groundwater has been identified as viable source for drinking water. This paper was aimed to investigate groundwater’s quality at specific location and metakaolin’s potential in the groundwater treatment in the removal of manganese. Groundwater purging was determined to be sufficient at 120 minutes where all three parameters (pH, dissolved oxygen and conductivity) were stabilized. The groundwater studied is classified as both anoxic and reductive due the low dissolved oxygen value. It also can be categorized as brackish due to high value of conductivity and total dissolved solid. Manganese content in groundwater was determined as higher than of that permissible limit for raw water and drinking water which makes it unsuitable for them not suitable for consumption and cleaning purpose. Average manganese concentration in samples was 444.0 ppb where the concentrations of manganese ranged from 229.4 ppb to 760.3 ppb. Manganese developed is not that a strong positive correlation against iron concentration, total dissolved solids and conductivity; whereas has a moderate negative correlation against dissolved oxygen. The capability adsorption of manganese by metakaolin was assessed via batch method which indicated optimum dosage and contact time was 14g that removed average 30.2% and contact time optimum at 120 minutes which removed 33.2% manganese from the sample.
PL
Jednym z najważniejszych zagadnień projektowych, ale również eksploatacyjnych, w usuwani z wody żelaza, a także pośrednio manganu, jest wyznaczanie wysokości poszczególnych stref technologicznych - tj. strefy odżelaziania oraz odmanganiania wody. Parametr ten, częstokroć pomijany jest niejednokrotnie kluczem do ustalenia przyczyn problemów z usuwaniem żelaza oraz manganu, tak w układach jedno- jak i dwustopniowej filtracji.
EN
The study investigated the efficiency of removal of iron, manganese and indicator bacteria from potable groundwater by using carbonate-silica rock (opoka). The tests were performed in a laboratory in three filter columns supplied with water containing increased concentrations of iron and manganese. Two of the columns were filled with carbonate-silica rock with particle sizes of 2–5 mm; retention time for water in the columns was set at 1 h and 2 h. A third column was filled with 1–2 mm rock particles, with hydraulic retention time set at 1 h. High removal efficiencies were determined for iron, manganese and coliform bacteria and low removal efficiencies for psychro- and mesophilic bacteria. An increase in the alkalinity of the investigated water was also observed.
PL
W pracy przeanalizowano skuteczność usuwania żelaza, manganu i bakterii wskaźnikowych z wody podziemnej przeznaczonej do picia. Stosowano w tym celu skałę węglanowo-krzemionkową (opokę). Badania wykonano w warunkach laboratoryjnych w trzech kolumnach filtracyjnych zasilanych wodą o zwiększonej zawartości żelaza i manganu. Dwie z kolumn wypełniono skałą węglanowo-krzemionkową (opoką) o granulacji 2–5 mm, czas retencji wody w kolumnach ustalono odpowiednio na 1 i 2 h. Trzecią kolumnę wypełniono skałą o granulacji 1–2 mm, przyjmując czas retencji wody 1 h. Stwierdzono dobre efekty usuwania żelaza i manganu i bakterii grupy coli z badanych wód, niewielką skuteczność usuwania bakterii psychro- i mezofilnych, a także zwiększenie zasadowości wody.
PL
W artykule przedstawiono najczęściej występujące problemy z jakimi można się spotkać analizując dokumentacje projektowe oraz dokonując wizji lokalnych stacji wodociągowych. Te niedomagania ujawniają się najszybciej podczas wykonywania ekspertyz przy stawianiu diagnoz i rozwiązywaniu problemów. Analiza obejmuje współpracę pomp studziennych z filtrami, wybór sposobów aeracji wody, a także występujące problemy związane z niedostatecznym odkwaszeniem lub zapowietrzaniem się złóż, doborem złóż filtracyjnych - materiały, granulacja, współczynniki nierównomierności oraz problemy z projektowaniem i eksploatacją układów płucznych. Wykazano najczęściej pojawiające się błędy, ich przyczyny i sposoby poprawy.
EN
The paper presents the most common problems you can encounter, analyzing project documentation, making the vision of the local waterworks. These inefficiencies manifest themselves quickly when performing expertise in making the diagnosis and troubleshooting. The analysis involves working well pump with filters, choice of ways of aeration for water and common problems associated with insufficient or de-acidification of air pockets from the deposits, the selection of filter beds - materials, granulation, the coefficients of inequality and the problems with the design and operation of backwashing systems. It has been shown frequently occurring errors, their causes and ways to improve.
PL
W artykule przedstawione zostały wyniki pomiarów rozkładów wielkości cząstek zawiesin zawartych w popłuczynach pochodzących ze stacji uzdatniania wód podziemnych w Golędzinowie. Próbki popłuczyn pobierano w trzech seriach badawczych w trakcie płukania filtrów do odżelaziania i odmanganiania w okresie od 20 sierpnia 2013 roku do 6 marca 2014 roku. Do oznaczenia składu granulometrycznego zawiesin użyto granulometr laserowy Mastersizer 2000. Badania wykazały, że w trakcie płukania filtrów rozkład wielkości cząstek zawiesin był zmienny. W zawiesinie w ujęciu objętościowym dominowały cząstki o wielkościach 1-100 μm, a w ujęciu ilościowym 0,1-1 μm. Dodatkowo dla filtra odmanganiającego we wszystkich fazach płukania uzyskiwano wyższe wartości wielkości cząstek niż w przypadku filtra odżelaziającego.
EN
The study presents the results of measurement of particle size distribution in suspensions contained in spent filter backwash water obtained from the Groundwater Treatment Plant in Golędzinów. Spent filter backwash water samples were collected in three test series during the backwashing of iron and manganese removal filters, during the period from the 20th of August, 2013 to the 6th of March, 2014. Granulometric composition was determined by means of Mastersizer 2000 laser granulometer. The tests have proven that during the backwashing of filters the particle size distribution in suspensions was subject to changes. In terms of volume, particles of a size of 1-100 μm were dominant in the suspension, while in quantitative terms – particles of a size of 0.1-1 μm. Additionally, for the manganese removal filter higher particle size values were obtained in all stages of backwashing than for the iron removal filter.
EN
In this work a comparative study of manganese removal from pre-treated acid mine drainage is described. Manganese removal by three ways was realized. At the first method sodium hydroxide was added to raise pH of processed AMD to the 9.5 to promote the abiotic oxidation of soluble divalent species to insoluble form of manganese. Potassium permanganate was used at pH near neutrality for elimination of manganese from AMD by oxidative precipitation in the second process. A third method, as electrowinning, was applied, finalized to the anodic Mn recovery under MnO2 form. The results showed that the three methods are effective and manganese were removed from acid mine drainage for values that comply with environmental requirements. However, when sodium hydroxide was used as reagent, coprecipitation of manganese and magnesium present in AMD was observed. In the second experiment enhanced selectivity of the process and purity of obtained precipitates were achieved. In the process of electrowinning – over 95% of Mn removal under MnO2 form, with a high degree of purity (about 99%) was attained.
PL
W pracy tej opisano porównawcze badanie usuwania manganu z przygotowanego drenażu kwaśnych wód kopalnianych. Usuwanie manganu odbyło się na trzy sposoby. Po pierwsze, dodano wodorotlenek sodu aby podnieść pH przerabianego AMD do 9.5 aby spowodować abiotyczne utlenianie rozpuszczalnych dwuwartościowych gatunków do nierozpuszczalnej formy manganu. Nadmanganian potasu zastosowano przy pH bliskim poziomu neutralnego aby wyeliminować mangan z kwaśnych wód kopalnianych poprzez tlenowe strącanie w drugiej metodzie. Trzecia metoda, jako elektrolityczna, została zastosowana do anodowego odzysku Mn w formie MnO2. Wyniki wskazały, że trzy metody są efektywne i mangan został usunięty z drenażu kwaśnych wód kopalnianych w ilościach porównywalnych z wymaganiami środowiskowymi. Jednakże, przy zastosowaniu wodorotlenku sodu zaobserwowano wzajemne strącanie manganu i magnezu obecnego w kwaśnych wodach kopalnianych. W drugim eksperymencie zwiększona została selektywność procesu i czystość otrzymanych substancji. W procesie elektrolitycznym – ponad 95% Mn zostało usuniętych w postaci MnO2, przy dużym stopniu czystości (około 99%).
PL
Wody podziemne o ponadnormatywnej zawartości żelaza i manganu oczyszczane są w prostych układach technologicznych, złożonych głównie z napowietrzania i filtracji. Układy te, w zależności od składu wody, mogą być rozbudowane, a także charakteryzować się różną efektywnością oczyszczania. W publikacji przeprowadzono przegląd wybranych badań dotyczących usuwania Mn(II) i Fe(II). Wykazano duże znaczenie w badanym procesie stężenia tlenu, substancji zredukowanych i humusowych, a także mas aktywnych wykazujących właściwości katalityczne.
EN
Groundwaters with a high iron and manganese content are treated in simple technological systems, comprising mainly aeration and filtration. The system configurations as well as their efficiency may vary, depending on the water composition. The paper reviews selected studies on the removal of Mn (II) and Fe (II). It has been shown that an oxygen concentration as well as reduced and humic compounds and active masses of catalytic properties play an important role in the process.
PL
W pracy dokonano oceny skuteczności technologii dwustopniowego oczyszczania wody podziemnej, wdrożonej w zmodernizowanym zakładzie oczyszczania wody zaopatrującym Gliwice. Do utlenienia rozpuszczonych w wodzie związków żelaza(II) i manganu(II) zastosowano zarówno tlen, jak i ozon, a wytworzone nierozpuszczalne związki tych metali były następnie zatrzymywane w złożach filtrów piętrowych. Wyniki badań przeprowadzonych w skali technicznej wykazały, że zastosowane procesy utleniania i filtracji umożliwiły osiągnięcie zadowalającego stopnia usunięcia związków żelaza i manganu z wody, a także zmniejszenie intensywności barwy wody i mętności. Końcowa skuteczność usuwania związków żelaza i manganu była bardzo wysoka i wynosiła prawie 99%. Wykazano, że zastosowana technologia oczyszczania wody podziemnej, w której proces napowietrzania połączono z zawracaniem gazu wylotowego z komór kontaktowych ozonu i filtracją pospieszną zapewnia dużą skuteczność odżelaziania wody o małej zawartości związków organicznych. W wyniku tych samych procesów jednostkowych z wody był usuwany częściowo również mangan, a wysoki stopień jego usunięcia zapewniło utlenianie jonów Mn(II) za pomocą rozpuszczonego w wodzie ozonu w połączeniu z filtracją pospieszną na złożach wpracowanych.
EN
Effectiveness of two-step groundwater treatment technology implemented at an upgraded water treatment plant supplying the city of Gliwice was assessed. For oxidation of soluble forms of Fe(II) and Mn(II) both oxygen and ozone were applied, while insoluble metal species were captured at multistage pressure filters. The results of experiments carried out on the technical scale demonstrated that the applied aeration and filtration techniques led to satisfactory iron and manganese removal as well as reduction in water color and turbidity. The overall effectiveness of iron and manganese removal was very high and amounted to almost 99%. It was demonstrated that the groundwater treatment technology, where the aeration stage was coupled with gas recirculation from ozone contact tanks and rapid filtration, was highly effective in terms of iron removal from water of low organic content. Additionally, the same unit processes led to partial manganese removal. High level of its elimination was ensured by oxidation of Mn(II) ions by water-soluble ozone coupled with rapid filtration at ripened filter beds.
PL
Wykorzystanie wód popłucznych z płukania złóż filtracyjnych, poprzez ich zawracanie na początek układu oczyszczania wody, stanowi skuteczne rozwiązanie technologiczne, które znajduje coraz większe zainteresowanie wśród operatorów stacji wodociągowych. Recyrkulacja wód popłucznych pozwala na zmniejszenie kosztów ujmowania wody (pompowanie, opłaty za korzystanie ze środowiska) oraz kosztów odprowadzania popłuczyn do kanalizacji lub środowiska. W pracy omówiono skuteczność oczyszczania wód popłucznych w zmodernizowanym ciągu technologicznym zagospodarowania tych wód w stacji oczyszczania wody „Mosina”. Ocenę tego procesu przeprowadzono na podstawie danych eksploatacyjnych uzyskanych po trzyipółletnich obserwacjach (2012–2015) oraz wyniki badań fizyczno-chemicznych i bakteriologicznych wód. Przedstawiono także korzyści i zagrożenia wynikające z recyrkulacji wód popłucznych w układzie oczyszczania wód podziemnych. Dotychczasowe wyniki eksploatacyjne wykazały jednoznacznie, że zastosowanie procesu koagulacji w układzie oczyszczania wód popłucznych pozwala na uzyskanie ich jakości porównywalnej z jakością ujmowanych wód podziemnych.
EN
Use of backwash water from filter beds by its recirculation to the treatment plant is an effective technological solution gaining attention of water supply system operators. Filter backwash recycling allows reducing water intake costs (pumping, environment taxes) and costs of water discharge into drains or the environment. The paper discusses effectiveness of the backwash water treatment in the modernized technological train of WTP Mosina. An assessment of the process was conducted on the basis of the operational data collected during the past three-and-a-half-year period (2012–2015) and both physico-chemical and bacteriological test results. Additionally, the risks and benefits of the backwash water recycling in the groundwater treatment train were presented. The up-to-date operational results have clearly shown that coagulation applied in the backwash water treatment train allows obtaining quality comparable with that of raw groundwater.
EN
PACls overdosage has negative impact on the operation and the effectiveness of coagulation and separation of post-coagulation suspensions. The results of the pilot study revealed that a sharp increase of fine particles was observed at reaching and exceeding the isoelectric point. Based on the full-scale research with PACl_1 (B = 2, 4) it was stated that these particles did not cause deterioration of standard quality parameters (turbidity, absorbance UV254, colour, TOC, CODMn) of water purified in conventional treatment. However, the particles not retained in sedimentation tanks supplied rapid filters and caused their overloading, and hence shortening of filtration cycles.
14
Content available remote Odmanganianie wody w filtrach ze złożem katalitycznym
PL
Celem badań było określenie efektywności usuwania manganu z wody w filtrze doświadczalnym z użyciem mas katalitycznych G-1 i G-2. Woda poddawana oczyszczaniu pochodziła z ujęcia podziemnego, charakteryzowała się stosunkowo wysoką zawartością żelaza i manganu, a jej odczyn wynosił poniżej 7. Filtr doświadczalny pracował jako pierwszy lub jako drugi stopień filtracji. W pracy oceniono skuteczność odmanganiania wody przy zmiennej szybkości filtracji wody. Badano również zmiany efektywności oczyszczania wody oraz szybkość przyrostu oporów filtracji w trakcie trwania cyklu filtracyjnego. Kontrolowano wpływ odczynu wody na skuteczność oczyszczania wody.
EN
The aim of study was determination of effectiveness of manganese removal from water on experimental filter with the use of catalytic materials G-1 and G-2. Treated water derived from underground intake, characterized in relatively high amount of iron and manganese and its pH was below 7. Experimental filter operated as a first or as a second filtration stage. In the work it was evaluated effectiveness of manganese removal from water at different filtration rate. It was also investigated changes of water treatment effectiveness and increasing rate of filtration resistances during filtration cycle. Influence of pH on water treatment efficiency was controlled.
PL
Uzdatnianie wód podziemnych zawierających nadmierne ilości żelaza i manganu jest procesem dość dobrze poznanym i szeroko opisywanym w literaturze. W praktyce okazuje się jednak, że każda woda podziemna wymaga indywidualnego podejścia. W pracy zaprezentowano doświadczenia z modernizacji technologii usuwania żelaza i manganu z wody podziemnej ujmowanej w SUW Leśna w Zabrzu. Wykazano, że można skutecznie uzdatnić wodę przy użyciu prawie 10-krotnie mniejszych dawek chloru dla utlenienia żelaza i manganu. Wykazano, że zmiana złoża filtracyjnego pozwala na wydłużenie cykli filtracyjnych z 8 godzin do 96 godzin.
EN
Underground water treatment with high iron and manganese concentration is a well know process and there are many scientific publications on the subject. It turns out in practice that every type of ground water requires a distinctive approach. The paper discuses the modernization of technology and treatment apparatus at the ”Leśna” ground water treatment plant in Zabrze. The effects show that water may be effectively treated using less than a tenfold dose of chlorine for iron and manganese oxidation. By changing the filtration bed the length of each filtration cycle can increase from 8 to 96 hours.
PL
Skład granulometryczny zawiesin zawartych w popłuczynach z filtrów ma wpływ na wybór technologii ich oczyszczania. W artykule przedstawiono wyniki badań składu granulometrycznego zawiesin zawartych w popłuczynach pobranych z 46 stacji oczyszczania wód podziemnych. Do interpretacji wyników badań składu granulometrycznego, ustalanego za pomocą granulometru laserowego, wykorzystano oryginalne, zaproponowane przez autorów, zmodyfikowane równanie Avramiego, pozwalające identyfikować mechanizm tworzenia się zawiesin w złożach filtracyjnych do usuwania związków żelaza i manganu z wód podziemnych. Wykazano, że przy wzroście zawartości żelaza i manganu w wodzie wzrastał w popłuczynach udział zawiesin o małych średnicach zastępczych i zwiększał się przedział zmienności oznaczanych średnic zastępczych cząstek. Przy małej zawartości żelaza i manganu w oczyszczanej wodzie powstawały zawiesiny polidyspersyjne o mniejszym przedziale zmienności średnic zastępczych.
EN
Granulometric composition of suspensions contained in filter backwash water affects filter treatment technology selection. The paper describes results of granulometric composition studies on filter backwash water suspensions collected from 46 groundwater treatment plants. An original, modified Avrami equation was proposed to interpret the results of studies on granulometric composition determined by the use of laser diffractometer. The equation enabled identification of mechanism in which suspensions are formed in filter beds applied for groundwater iron and manganese removal process. The research showed that iron and manganese concentration growth in treated groundwater correlated with increase in the percentage of suspended particles with small equivalent diameter and in changeability range of particle equivalent diameters in backwash effluent. At low contents of iron and manganese compounds in treated water polydisperse suspensions were formed, characterized by narrower changeability range of particle equivalent diameters.
EN
A study algorithm of filtration materials susceptibility to autoactivation with manganese dioxide was presented, in the example of chalcedonite sand. This algorithm may serve as a basis for preliminary research plan development for groundwater treatment plant purposes. The proposed methodology was verified in studies on iron and manganese removal from groundwaters by filtration using chalcedonite as well as, for comparative purposes, quartz and anthracite-quartz sands. Technological characteristics of chalcedonite, quartz and anthracite-quartz deposits were received under the same research conditions and in line with the methodology developed. This allowed the manganese dioxide assisted autoactivation processes to be compared and a definite prevalence of chalcedonite over quartz and anthracite-quartz sands in the process of iron and manganese removal from water was demonstrated.
PL
Przedstawiono algorytm badania podatności materiałów filtracyjnych, ze szczególnym uwzględnieniem chalcedonitu, na autoaktywację dwutlenkiem manganu. Algorytm ten może służyć do opracowania planu badań przedprojektowych na potrzeby zakładów oczyszczania wód podziemnych. Proponowana metodyka została zweryfikowana w badaniach doświadczalnych odżelaziania i odmanganiania wód podziemnych, prowadzonych w złożu chalcedonitowym i porównawczo w złożach kwarcowych i antracytowo-kwarcowych. Wyznaczone zgodnie z opracowaną metodą charakterystyki technologiczne złoża chalcedonitowego, kwarcowego i antracytowo-kwarcowego, uzyskane w takich samych warunkach badawczych, pozwoliły porównać proces autoaktywacji tych złóż dwutlenkiem manganu i wykazać wyraźną przewagę złoża chalcedonitowego nad złożami kwarcowym i antracytowo-kwarcowym w procesie odżelaziania i odmanganiania wody.
PL
Związki manganu występujące w wodach powierzchniowych praktycznie nie są usuwane podczas procesu koagulacji. Technologia oczyszczania wody stosowana w zakładzie wodociągowym "Czaniec", oparta na filtracji kontaktowej z wykorzystaniem siarczanu glinu, nie zapewnia usunięcia związków manganu, które okresowo występują w wodzie ujmowanej ze zbiornika zaporowego nawet w ilości 0,6 gMn/m3. Badania testowe przeprowadzone w skali technicznej wykazały, że dawkowanie nadmanganianu potasu w ilości 0,7 gKMnO4/m3 przed filtrami kontaktowymi (razem z koagulantem) umożliwiło skuteczne usunięcie związków manganu z 0,140÷0,605 gMn/m3 do wartości dopuszczalnej (0,05 gMn/m3). Roczne doświadczenia eksploatacyjne w skali całego zakładu wodociągowego wykazały, że dawka nadmanganianu potasu zależała nie tylko od zawartości związków manganu, ale także od ogólnego składu ujmowanej wody. Wprowadzenie do technologii oczyszczania wody nadmanganianu potasu zapobiegło konieczności czasowego wyłączania zakładu spowodowanego dużą zawartością związków manganu w ujmowanej wodzie.
EN
Manganese compounds that occur in surface water are virtually not removed during coagulation. The treatment train applied in the Czaniec Waterworks, which includes contact filtration and the use of aluminum sulfate, practically fails to remove the manganese compounds that periodically occur in the impoundment lake, even if their concentration amounts to 0.6 gMn/m3. Full-scale tests have shown that potassium permanganate doses of 0.7 gKMnO4/m3 applied before the contact filters (with aluminum sulfate) provided efficient removal of manganese compounds from the level of 0.140-0.605 gMn/m3 to the admissible value of 0.05 gMn/m3. Experience gained during one-year observations has shown that the size of the potassium permanganate dose depends not only on the manganese compound content, but also on the concentration of the other lake water components. The inclusion of potassium permanganate into the treatment train eliminated the necessity for temporary discontinuation of the treatment process as a consequence of the high manganese content of the water entering the plant.
PL
Artykuł prezentuje metodykę postępowania w określaniu przydatności technologicznej nowych materiałów filtracyjnych do usuwania żelaza oraz manganu z wody. Autorzy opracowali algorytm postępowania, który określa ścieżki postępowania przy interpretacji danych uzyskanych w toku badań technologicznych, pozwalający przeanalizować istotne z punktu widzenia omawianych procesów dane, jak i wyznaczyć najistotniejsze charakterystyki technologiczne. W artykule przedstawiono również wyniki badań złoża chalcedonitowego, analizowane w oparciu o omawiany algorytm interpretacji.
EN
The paper presents methods of research on determination of technological suitability of new filtration materials for iron and manganese removal from water. Authors created algorithm of interpretation of research results, collected during the technological experiment, allowing to establish important parameters as well as technological characteristics. In the paper the interpretation of chalcedonit research according to established algorithm is presented.
20
Content available remote Odżelazianie i odmanganianie wód podziemnych w złożach chalcedonitowych
PL
Wyniki badań nad procesem filtracji wód podziemnych przez złoże filtracyjne z piasku chalcedonitowego. Badania pilotowe obejmowały serię, w której porównano efektywności odżelaziania i odmanganiania złoża antracytowo kwarcowego i złoża chalcedonitowego. W drugiej serii prowadzono filtrację przez chalcedonit z prędkościami filtracji równymi 6, 9, i 12 m/h. Na podstawie wyników badań wyznaczono efektywność filtracji, wysokości stref odżelaziania i odmanganiania oraz czasy wpracowania złoża chalcedonitowego.
EN
The results of the process of filtration of groundwater by a chalcedonit sand filter bed. On the basis of test results were determined the size of zones of iron and manganese removal and the time of form chalcedonit deposit.