Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 30

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  manekin termiczny
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
Every day, firefighters put their health and life at risk by saving people and their property not only during fires, but by being always ready during all kinds of unfortunate events. Therefore, they need special personal protective equipment, including protective clothing. The purpose of the study was to compare thermal properties of new (PROTON and SYRIUSZ) and old (US-03) personal protective clothing for firefighters. Measurements of thermal insulation (total, effective and local) were carried out using a full body shape thermal manikin Newton consisting of 34 segments, in which temperature and heat flux were controlled independently. Results of the total thermal insulation of the entire clothing reveal differences between all three models. The lowest values were noticed for the model PROTON with light and shorter jacket and the highest values of thermal insulation for the new model SYRIUSZ, indicating that this model protect the user against heat most effectively. New models of personal protective clothing for firefighters should be recommended for use in everyday work, because they are characterized by better parameters than the previous type of protective clothing, both in terms of thermal protection and mobilit.
PL
Codziennie strażacy narażają swoje zdrowie i życie, ratując ludzi i ich mienie nie tylko podczas pożarów, ale będąc zawsze w gotowości podczas wszelkiego rodzaju nieszczęśliwych zdarzeń. Dlatego też potrzebują oni specjalnych środków ochrony osobistej, w tym odzieży ochronnej. Celem pracy było porównanie właściwości termicznych nowej (PROTON i SYRIUSZ) i starej (US-03) odzieży ochronnej dla strażaków. Pomiary izolacyjności cieplnej (całkowitej, efektywnej i miejscowej) przeprowadzono przy użyciu manekina termicznego Newton o pełnym kształcie ciała, składającego się z 34 segmentów, w którym niezależnie kontrolowano temperaturę i strumień ciepła. Wyniki dotyczące całkowitej izolacji cieplnej całej odzieży wykazują różnice pomiędzy wszystkimi trzema modelami. Najniższe wartości odnotowano dla modelu PROTON z lekką i krótszą kurtką, a najwyższe dla nowego modelu SYRIUSZ, co wskazuje, że ten model najskuteczniej chroni użytkownika przed gorącem. Nowe modele odzieży ochronnej dla strażaków powinny być rekomendowane do stosowania w codziennej pracy, gdyż charakteryzują się lepszymi parametrami niż dotychczasowy typ odzieży ochronnej, zarówno pod względem ochrony termicznej, jak i mobilności.
EN
Aim: An extremely important property of firefighters’ special clothing is thermal resistance of the clothing materials to heat transfer from radiation or flame. Performing tests with the use of thermal mannequins may contribute to the improvement of clothing sets, as such tests indicate weak points of the tested products. The review article presents information on the testing of special clothing on mannequins and a short history of test stands with the use of thermal mannequins. Introduction: Using innovative techniques and technologies provides firefighters-rescuers with an appropriate level of safety. Special clothing is a barrier between the human body and the heat and water vapour from the environment. It is this garment that protects the human body from overheating or cooling down. Methodology: The general test procedure for using thermal mannequins is described in ASTM standards (for instance ASTM F2370 – 10 [1], ASTM F2371 – 10 [2]). Testing of special clothing allowing for an accurate assessment of the degree of protection of the human body against the effects of fire, flame and heat was initiated in the United States. The assumption of these works was to create a mannequin for testing the resistance of clothing equipped with heat sensors to flash fires. Currently, there are around 100 different models of thermal mannequins around the world. Technological progress in the post-war period resulted in the rapid development of mannequins built with a multi-segment structure. This allowed to increase the accuracy of the measurements that simulated heat exchange between the human body and the environment. The data obtained in this manner is repeatable, which allows for standardization of the test requirements for thermal insulation of clothing sets. Conclusions: Performing tests using thermal mannequins contributes to the improvement of clothing sets in order to increase the safety of the users. The results obtained under the test conditions very accurately indicate the number, location and degree of burns to which the user of such clothing may be exposed.
PL
Cel: Niezwykle ważną właściwością strażackich ubrań specjalnych jest odporność termiczna materiałów odzieżowych na przenikanie ciepła pochodzącego z promieniowania lub płomienia. Wykonywanie badań przy użyciu manekinów termicznych może przyczynić się do udoskonalania zestawów odzieżowych, bowiem badania takie wskazują słabe punkty testowanych wyrobów. W artykule mającym charakter przeglądowy przedstawiono informacje na temat prowadzonych badań ubrań specjalnych na manekinach oraz krótką historię stanowisk badawczych z wykorzystaniem manekinów termicznych. Wprowadzenie: Zastosowanie innowacyjnych technik i technologii zapewnia strażakom-ratownikom odpowiedni stopień bezpieczeństwa. Odzież specjalna stanowi barierę pomiędzy ludzkim ciałem a ciepłem i parą wodną pochodzącymi ze środowiska. To właśnie ubranie ma za zadanie chronić ciało człowieka przed nadmiernym przegrzaniem lub wychłodzeniem. Metodologia: Ogólna procedura postępowania badawczego z wykorzystaniem manekinów termicznych opisana jest w standardach ASTM (np. ASTM F2370 – 10 [1], ASTM F2371 – 10 [2]). Badania odzieży specjalnej pozwalające na dokładną ocenę stopnia ochrony ludzkiego ciała przed działaniem ognia, płomienia i ciepła zapoczątkowano w Stanach Zjednoczonych. Założeniem wspomnianych prac było stworzenie manekina do badania odporności odzieży na działanie pożarów błyskawicznych, wyposażonego w czujniki ciepła. Obecnie na świecie funkcjonuje ok. 100 różnych modeli manekinów termicznych. Postęp technologiczny w okresie powojennym spowodował szybki rozwój budowanych manekinów, które posiadały wielosegmentową budowę. Pozwoliło to na zwiększenie dokładności wykonywanych pomiarów symulujących wymianę ciepła między organizmem ludzkim a otoczeniem. Uzyskane w ten sposób dane są powtarzalne, co pozwala na znormalizowanie wymagań badawczych izolacyjności cieplnej zestawów odzieżowych. Wnioski: Wykonywanie badań przy użyciu manekinów termicznych przyczynia się do udoskonalania zestawów odzieżowych, aby zwiększać bezpieczeństwo użytkowników. Uzyskane w warunkach badawczych wyniki w bardzo dokładny sposób wskazują liczbę, lokalizację i stopień oparzeń, na jakie może być narażony użytkownik takiego ubrania.
EN
Specialist clothing for firefighters must comply with a number of various standards in terms of e.g. water vapour resistance. The use of different materials and constructional solutions may affect the results of thermal parameters of the clothing. A search for new solutions can lead to ergonomic products. The aim of the article was to show whether there were differences in thermal parameters between the special clothing currently used for firefighters in Poland and clothing that takes into account new materials and trends in the construction of the above-mentioned type of clothing. The research results indicate no difference between the sets of clothing tested in terms of global thermal parameters; however, differences are recorded for values of local thermal insulation and water vapour resistance. These differences are attributable mainly to the construction of the clothing and not to the materials used.
PL
Specjalistyczna odzież dla strażaków musi spełniać wymagania różnych standardów pod kątem np. oporu pary wodnej. Zastosowanie różnych materiałów oraz rozwiązań konstrukcyjnych może wypływać na wyniki parametrów termicznych odzieży. Poszukiwanie nowych rozwiązań może prowadzić do uzyskania ergonomicznych produktów. Celem artykułu było wykazanie, czy istnieją różnice w parametrach termicznych pomiędzy obecnie używaną odzieżą specjalną dla strażaków w Polsce a odzieżą uwzględniającą nowe materiały i trendy w konstrukcji w w/w typie odzieży. Wyniki badań wskazały na brak różnicy pomiędzy badanymi zestawami odzieży pod kątem globalnych parametrów termicznych, jednak odnotowano różnice w wartościach lokalnych izolacyjności cieplnej oraz oporu pary wodnej. Różnice te wynikały głównie z konstrukcji odzieży, a nie z zastosowanych materiałów.
EN
This paper describes the characteristic thermal parameters of firefighters’ personal protective clothing (FFPPC) used in Poland. The total thermal insulation and evaporative resistance of three different types of FFPPC were measured and used on a thermal manikin. Next, the results were compared. Based on the analyses and calculations of the test results, it was shown that FFPPC provides a barrier to the heat exchange between the user and the surrounding environment. Differences in the local thermal insulation can be triggered not only by the material used but they can also be attributable to clothes fitted on the manikin. The biggest differences can be noted on the segments forming part of the manikin’s trunk. No difference was found in the evaporative resistance between the clothes tested. In order to examine further the impact of the materials used on thermal parameters of protective clothing, it is necessary to carry out an analysis of the impact of individual layers.
PL
W artykule opisano charakterystyczne parametry termiczne odzieży ochronnej dla strażaków (FFPPC) stosowanej w Polsce. Zmierzono całkowitą izolacyjność cieplną oraz opór pary wodnej dla trzech różnych zestawów FFPPC przy wykorzystaniu manekina termicznego. Porównano uzyskane wyniki. Na podstawie obliczeń i analizy wyników badań wykazano, że FFPPC stanowi barierę dla wymiany ciepła pomiędzy użytkownikiem a otoczeniem. Różnice w lokalnych wartościach izolacyjności cieplnej mogą wynikać nie tylko z powodu zastosowania różnych materiałów, ale również mogą być związane z dopasowaniem ubrania do manekina. Największe różnice zauważono na segmentach korpusu manekina. Nie stwierdzono różnic w wartościach oporu pary wodnej pomiędzy badanymi ubraniami. W celu dalszego zbadania wpływu zastosowanych materiałów na parametry termiczne odzieży ochronnej, należałoby przeprowadzić oddzielne analizy dla poszczególnych warstw konstrukcji badanych zestawów odzieży.
PL
Obecnie na rynku tekstylnym wytwarzane są coraz bardziej innowacyjne wyroby odzieżowe, co związane jest z nieustannym rozwojem technologii. Dynamiczny rozwój nowych technologii i obecny stan techniki pozwala naukowcom na wykonywanie bardzo dokładnych pomiarów. Możliwe są różnorodne analizy porównawcze wyników badań tego samego parametru na dwóch, bądź większej liczbie urządzeń. W artykule przedstawiono analizę porównawczą rozkładu temperatur na poszczególnych częściach ciała przeprowadzoną na manekinie termicznym i kamerze termowizyjnej podczas badania rajstop. Uzyskane wyniki badań przeprowadzone na obu urządzeniach były porównywalne zarówno dla rajstop z mikrokapsułkami, jak i bez. Stwierdzono, wyższe wartości temperatury na powierzchni rajstop zawierających mikrokapsułki z mentolem.
EN
Currently, on the textile market, more and more innovative clothing products are manufactured, which is associated by the constant development of new technologies. The dynamic development of new technologies and the current state of art allows scientists to make very accurate measurements. Currently, various comparative analyzes of from test results two or more devices that examine the same parameter are possible. The article presents a comparative analysis of the temperature distribution on individual body parts carried out on the thermal manikin and thermal imaging camera at tights. Obtained results of tests carried out on both devices were comparable for both tights with and without microcapsules. Higher temperature values were found on the surface of tights containing microcapsules with menthol.
EN
According to the standards describing research on the total and resultant thermal insulation [1-3], the requirements for the microclimate in which tests are performed must be recorded. However, these values are given with uncertainty. According to the EN ISO 15831 [1] and EN 342 [2] standards, air velocity should be set to (0.4 ± 0.1) m/s. For this reason, it is necessary to verify to what extent values exceeding the said range affect the results of the thermal insulation. Research was carried out for 3 sets of clothing differing in the numer of layers of the material. The influence of air velocity on clothing thermal insulation was examined with three values of Va: 0.4 m/s, 0.8 m/s and 1.2 m/s. Correction factors (CFs) were calculated and compared with the CF values set out in the EN ISO 9920 standard [3].
PL
Zgodnie ze standardami, które opisują badania dotyczące całkowitej i wynikowej izolacyjności cieplnej wymagania dotyczące parametrów mikroklimatu, w których prowadzi się badania, powinny być zapisywane. Wartości te podawane są z niepewnością. Zgodnie z normami EN ISO 15831 i EN 342 prędkość powietrza powinna mieścić się w zakresie 0.4 ± 0.1 m/s. Z tego powodu konieczne jest sprawdzenie, w jakim stopniu wartości przekraczające wspomniany zakres mają wpływ na wyniki izolacyjności cieplnej. Badania przeprowadzono dla 3 zestawów odzieży różniących się liczbą warstw materiału. Wpływ prędkości przepływu powietrza na izolacyjność cieplną odzieży zbadano dla trzech wartości Va, tj.: 0.4 m/s, 0.8 m/s i 1.2 m/s. Obliczono współczynniki korygujące (CF) i porównano je z wartościami CF określonymi wg normy EN ISO 9920.
EN
In this study, the new tool for measuring thermal insulating power of garments for premature babies under coupled heat and moisture transport was developed. The thermal mannequin corresponds to the body weight and size of a premature baby born in the thirty fourth week of pregnancy. The mannequin surface temperature can be set at various levels, while the heat loss is measured in W/m2. The mannequin is divided into eleven independent heating zones and seven independent zones of moisture evolution. The study also presents the test results of heat insulating power obtained for the newly developed garment set with commercially available garment set for babies, conducted under different climatic conditions. The results exhibit the advantage of the new material construction of the garment over the commercially available one.
PL
Uwzględniając obecny rozwój inżynierii materiałowej, również w obszarze włókiennictwa, dostępność zróżnicowanych pod względem właściwości pakietów odzieżowych oraz rozwijające się zapotrzebowanie na odzież specjalnego przeznaczenia, pojawia się konieczność oceny komfortu biofizycznego kreowanego przez te wyroby. Ocena taka jest prowadzona na różnych etapach projektowania i produkcji. Niniejsza publikacja prezentuje porównanie wartości oporu cieplnego dla tkanin oraz izolacyjności cieplnej odzieży wytworzonej z tych tkanin. Tkaniny badano stosując metodykę zapisaną w normie PN-EN ISO 11092:2014-11, z wykorzystaniem metody pocącej się zaizolowanej cieplnie płyty, zaś ocenę izolacyjności cieplnej prowadzono w oparciu o normę PN-EN ISO 15831:2006 z zastosowaniem manekina termicznego NEWTON.
EN
Taking into account the current development of materials engineering, also in the field of textile industry, the availability of clothing packages with different properties in terms of properties and the growing demand for special-purpose clothing, there is a need to assess the biophysical comfort created by these products. This assessment is carried out at various stages of design and production. This publication presents a comparison of thermal resistance values for fabrics and thermal insulation of clothing made from these fabrics. The fabrics were tested using the methodology described in the PN-EN ISO 11092: 2014-11 standard, using the method of a heat-insulated thermal plate, and the assessment of thermal insulation was based on the PN-EN ISO 15831: 2006 standard using the NEWTON thermal manikin. Presented tests were done using three woven fabrics, differentiated by surface mass and the male shirts made from these wovens. Obtained results independently on similarities between measurements shows no correlation. It is assumed that the reason for the lack of correlation is the varied adaptation of the samples to the measurement system that occurs in both tests. This work is the introduction to further research.
EN
Foundry worker activity involves remaining in a high temperature while working close to a melting furnace. Special clothing made from aluminized fabrics for this action ensures protection against high temperature. However, the problem is that the existing so far suits have not been breathable. This paper the presents the utility comfort parameters of underwear goods which can be used under protective clothing. The special structure of underwear should assure the maintainance of constant temperature of the body. In order to compare the basic functions, namely ensuring comfort of use, innovative underwear products underwent measurements on a thermal manikin. Moreover a comparison between new raw material solutions of underwear and traditional cotton underwear was made. Additionally the air and water vapour permeability of knitted fabrics were measured. The aim of the study was also to determine such properties as the thermal insulation, air and water vapour permeability of underwear products that influence the physiological comfort of foundry workers in order to choose the best one for foundry worker activity.
PL
Podczas pracy przy piecu odlewniczym, pracownik narażony jest na działanie wysokiej temperatury. Ubranie ochronne dla odlewnika wykonane jest z aluminizowanej tkaniny, która zapewnia ochronę przed działaniem wysokiej temperatury. Brak przepuszczalności powietrza oraz pary wodnej specjalistycznej odzieży ochronnej stanowi duże utrudnienie wykonywania rutynowych czynności prac odlewniczych. W artykule podjęto próbę doboru bielizny, która zapewni komfort użytkowania podczas pracy w wysokiej temperaturze. W celu porównania komfortu użytkowania tradycyjnej bielizny bawełnianej z nowymi rozwiązaniami bielizny z zastosowaniem włókien syntetycznych oraz specjalnych konstrukcji splotów wykonano pomiary izolacyjności cieplnej różnych rodzajów bielizny na manekinie termicznym. Ponadto wykonano pomiary przepuszczalności powietrza i pary wodnej wybranych rodzajów bielizny. Analiza porównawcza pozwoliła na tym etapie badań wybrać bieliznę zapewniającą najlepszy poziom komfortu użytkowego w porównaniu z innymi wytypowanymi do badań typami bielizny.
10
Content available remote Temperatura ekwiwalentna jako wskaźnik do oceny odczuć środowiska cieplnego
PL
W niniejszym artykule zamieszczono informacje na temat temperatury ekwiwalentnej jako wskaźnika do oceny odczuć środowiska cieplnego z wykorzystaniem manekina termicznego. Na podstawie normy PN-EN ISO 14505-2:2007 podano definicje temperatury ekwiwalentnej teq, temperatury ekwiwalentnej całego ciała teq,whole body oraz temperatury ekwiwalentnej segmentu teq,segment. Opisano sposób pomiaru teq z wykorzystaniem manekinów termicznych oraz przykłady zastosowania temperatury ekwiwalentnej do oceny środowiska cieplnego.
EN
This paper contains information about the equivalent temperature as an index for the evaluation of environmental thermal sensations using a thermal manikin. Based on the standard PN-EN ISO 14505-2:2007, the definitions of the temperature equivalent teq, the equivalent temperature of the whole body teq,whole-body equivalent temperature teq,segment were given. The paper describes also a method for measuring teq using thermal manikins and some examples how to use teq for thermal environment assessment.
EN
This paper presents the results of thermal insulation measurements of beds, bedclothes and pyjamas, which are usually used by patients in hospitals. It was observed that the greatest impact on thermal insulation of clothes and accessories sets used in hospitals has a bed, and the smallest – a pillow. Simultaneously with the increase of thermas insulation of used items the temperature at which users may feel comfort is reduced – up to 13.5 °C.
PL
Izolacyjność cieplna czy opór pary wodnej odzieży są bardzo ważnymi parametrami w ocenie wystąpienia obciążenia cieplnego w każdym środowisku termicznym Badania tych parametrów wykonuje się wykorzystując do badań manekiny termiczne pozwalające na pomiar wymiany ciepła bez, jak i z uwzględnieniem pocenia. W artykule przedstawiono historię rozwoju manekinów termicznych. Przedstawiono manekiny termiczne znajdujące się na wyposażeniu CIOP-PIB oraz zamieszczono podstawowe informacje na temat pomiaru całkowitej izolacyjności cieplnej zestawu odzieży i oporu pary wodnej.
EN
Thermal insulation and evaporative resistance of clothing are very important parameters m evaluating thermal load in each thermal environment. Those parameters are studied with the use of thermal manikins for measuring thermal heat transfer with and without the sweating function. This article presents a brief history of thermal manikins. a short description of thermal manikins m CIOP-PIB's laboratory and also basic information on measuring total thermal insulation and evaporative resistance of clothing.
EN
The energy balance and heat exchange for newborn baby in infant care bed environment (radiant warmer) are considered. Convective and radiant heat losses from an infant in radiant warmer were studied using copper cast anthropomorphic thermal manikin and controlled climate chamber setup. The total body heat loss was measured for several mean skin and ambient temperatures, leading to total heat transfer coefficient estimation.
PL
Rozważany jest bilans energii oraz mechanizmy wymiany ciepła dla noworodka w otwartym inkubatorze dla niemowląt. Wykorzystano miedziany antropomorficzny manekin termiczny noworodka do zbadania konwekcyjnej i radiacyjnej wymiany ciepła z otoczeniem w komorze klimatycznej. Zmierzono całkowity strumień traconego ciepła dla wybranych średnich temperatur skóry oraz otaczającego powietrza, a następnie wyznaczono konwekcyjny współczynnik wnikania ciepła.
EN
The thermal insulation of clothing needs to be easily adjusted in an unsteady environment, but this is extremely difficult for most clothing. To reveal the effect of different styles of Tibetan clothing on their thermal property, the total thermal insulations of Tibetan clothing in three typical styles were measured using a thermal manikin. The clothing area factors (fcl) of the Tibetan clothing and body surface area covered by a Tibetan robe were tested with a photographic method. The results showed the following: 1) For similar insulation, fcl of Tibetan clothing is about 0.23 bigger than that of western clothing, estimated from ISO 11079; 2)the style of Tibetan clothing significantly affects the fcl (p < 0.05, fcl = 1.229 + 0.007 BSAC) and the intrinsic thermal insulation (p < 0.05, Icl = 0.166 + 0.016 BSAC); 3)the adjustable thermal insulation of Tibetan clothing proved its adaptability to the large air temperature difference environment on the Tibetan plateau ,which should be valuable for the product development of clothing used in a unsteady environment.
PL
Odzież powinna umożliwiać zmianę jej przewodności cieplnej w niestabilnym środowisku, jednak dla większości odzieży jest to niezwykle trudne. W celu określenia wpływu różnych stylów ubiorów tybetańskich na ich właściwości termiczne określono całkowitą izolację termiczna dla trzech typowych stylów odzieży tybetańskiej przy zastosowaniu manekina termicznego. Wpływ konfiguracji ubioru sprawdzono metodą fotograficzną za pomocą termowizji, określając jednocześnie powierzchniowy współczynnik okrycia ciała fcl. Wykazano, że 1) przy podobnej izolacji fcl ubiorów tybetańskich jest o 0.23 większy od ubiorów zachodnich (ISO11079); 2) styl ubiorów tybetańskich znacząco wpływa na fcl jak i wewnętrzną izolacje cieplną; 3) możliwość regulacji izolacji termicznej tybetańskiego ubioru zapewnia zdolność przystosowania się do dużych różnic temperatury otoczenia na płaskowyżu tybetańskim. Wyniki badań mogą znaleźć zastosowanie w projektowaniu odzieży noszonej w niestabilnym środowisku.
15
Content available remote Wpływ rodzaju manekina termicznego na pomiar izolacyjności cieplnej odzieży
PL
W artykule przedstawiono badania prowadzone w celu określenia czy rodzaj zastosowanego manekina termicznego (kształt jego powierzchni, liczba segmentów oraz specyfika działania) wpływa na wartość izolacyjności cieplnej odzieży mierzonej za pomocą tego urządzenia.
EN
The paper presents a study conducted to determine whether the nature of the thermal manikin (shape of the surface, number of segments and specific operations) influences quality of clothing thermal insulation measured by this device.
16
PL
W artykule przedstawiono wyniki badań strumieni konwekcyjnych kształtujących się nad manekinem termicznym. Przeprowadzono 3 warianty badań: manekin nagi oraz ubrany w odzież letnią i zimową. Zmiennym parametrem był brak lub też zastosowanie procesu oddychania. Wyniki badań potwierdziły wpływ oddychania na tworzenie się strumieni konwekcyjnych nad manekinem. Zastosowanie wydechu jednocześnie przez usta i nos manekina termicznego powodowało tworzenie się szerszego strumienia konwekcyjnego oraz wzrost jego prędkości maksymalnej.
EN
The paper presents the results of measurements of thermal plumes shaping over a thermal manikin. The study consisted of 3 variants: nude manikin and manikin wearing summer and winter clothing. Variable parameter was also the lack or the use of the breathing simulation process. The results confirmed the impact of breathing on the formation of thermal plumes above manikin. The use of exhale through the mouth and nose of manikin at the same time, resulted in the formation of larger convective flow and increase its maximum velocity.
EN
Thermal manikins were created with the intention to design and model protective clothing insulation for specific conditions, e.g. military clothing and clothing for divers. At present thermal manikins have a broader use, i.e. to assess the effect of clothing on a human body, to assess its influence on thermal comfort during work in a given clothing ensemble and to test innovative solutions bringing about a reduction in the thermal heat load. When using thermal manikins it should be borne in mind that heat exchange through clothing is, to a large extent, determined by the temperature distribution on human skin. The aim of the study was to find out to what extent thermal manikins can be used to represent the correct distribution of temperature on human skin. To this end, comparative measurements of the temperature distribution on the surface of a standard thermal manikin with a structure generally used and on the surface of the skin of volunteers were performed. The tests conducted showed that for the further development of thermal manikins computer software should be developed which would help to predict the temperature distribution on the manikin surface corresponding to the skin temperature of volunteers. Such software should allow for the simulation of thermal regulatory mechanisms in a human, i.e. an increase in skin temperature caused by vasoconstriction and shivering, as well as a decrease in skin temperature due to vasodilatation and sweating. In a thermally neutral environment, the methods which are currently used to control the thermal manikin seem to be sufficient.
PL
Termiczne manekiny zostały opracowane w celu projektowania i modelowania izolacyjności cieplnej odzieży ochronnej. Obecnie manekiny termiczne mają szerokie zastosowanie badawcze. Stosując manekiny termiczne należy pamiętać, że wymiana ciepła przez odzież zależy w dużej mierze od rozkładu temperatury skóry człowieka. Celem badań przedstawionych w artykule było sprawdzenie, w jakim stopniu manekiny termiczne mogą być używane do prognozowania prawidłowego rozkładu temperatury skóry człowieka. W tym celu przeprowadzono badania porównawcze rozkładu temperatury na powierzchni standardowego manekina termicznego powszechnie stosowanego w wielu laboratoriach badawczych i na powierzchni skóry ochotników. Przeprowadzone testy wykazały, że rozwój manekinów termicznych powinien być ukierunkowany w celu opracowania odpowiedniego oprogramowania komputerowego, które byłyby pomocne do prognozowania rozkładu temperatury na powierzchni manekina odpowiadającego temperaturze skóry ochotników.
18
Content available remote Nowa generacja manekinów termicznych
PL
W artykule przedstawiono nowoczesnego manekina termicznego oraz aparaturę badawczą tworzące zaplecze badawcze opracowane w celu projektowania i testowania urządzeń stosowanych do tworzenia komfortowego środowiska wewnętrznego.
EN
The paper presents a thermal manikin and modern research equipment for development and testing of systems used to create a comfortable indoor environment.
PL
W ostatnich latach obserwuje się rozwój technik CFD w modelowaniu przepływu powietrza w budynkach i poszczególnych pomieszczeniach. W programach CFD można wykonać obliczania bardzo skomplikowanych układów. Dzięki temu istnieje możliwość modelowania pomieszczeń o skomplikowanej geometrii, uwzględniając w nich ludzi, wyposażenie wewnętrzne, źródła ciepła konwekcyjnego i promienistego, wewnętrzne źródła ciepła, wentylację naturalną i mechaniczną oraz wpływ promieniowania słonecznego.
PL
Poznanie zachowania strumieni konwekcyjnych kształtujących się nad człowiekiem jest istotne ze względu na wymagania wentylacji pomieszczeń, jakości powietrza wewnętrznego oraz komfortu cieplnego użytkowników. W referacie przedstawiono wyniki badań przeprowadzonych przy wykorzystaniu metod CFD, w celu analizy możliwości i ograniczeń w symulacjach strumieni konwekcyjnych rozwijających się nad człowiekiem. W symulacjach zastosowano numerycznego manekina termicznego, będącego w pozycji siedzącej, o geometrii zgodnej z geometrią rzeczywistego ciała człowieka. Wyniki symulacji CFD porównano z wynikami badań prędkości powietrza w strumieniu konwekcyjnym formującym się nad manekinem termicznym (rzeczywistym) i człowiekiem.
EN
The behavior of the buoyant plume of air shed by a human being in an indoor environment is important to room ventilation requirements, indoor air quality and the thermal comfort of building occupants. In the tests described in this paper computational fluid dynamics (CFD) was used to analyze the possibilities and limitations of simulating thermal plumes developing above the human. In simulations a sealed computalional thermal manikin with geometry of a real human body was used. Results from CFD were compared with the results of real measurements of air velocities in thermal plume forming over the thermal manikin and the human.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.