1
Content available remote Vortex currents detected by stress MCGand fragmentation of ECG /MCG in VT patients
EN
The information content of electrocardiogram (ECG) and magnetocardiogram (MCG) is different. This is demonstrated by an investigation of the dependence of the signals on heart rate changes after physical exercise. For healthy volunteers the repolarization changes drastically in the MCG whereas no comparable changes are found in the ECG. A beat-to-beat analysis shows that in some cases an alternating T-wave is observed in the stress-MCG of healthy volunteers. The diagnostic value of both ECG and MCG for identifying patients at risk of ventricular tachycardia is demonstrated in three studies focusing on the depolarization phase of the signal.
PL
Informacja jaką zawiera elektrokardiogram (EKG) i magnetokardiogram (MKG) jest różna. Zostało to wykazane w badaniach zależności sygnałów od zmian częstości rytmu serca po wysiłku fizycznym. U zdrowych ochotników repolaryzacja zmienia się drastycznie w zapisie MKG, podczas gdy nie zostały znalezione porównywalne zmiany w EKG. Analiza beat-to-beat wykazuje, że w niektórych przypadkach obserwuje się zmieniony załamek T w wysiłkowym MKG u zdrowego ochotnika. Na podstawie trzech badań skupiających się na fazie depolaryzacji sygnału oszacowano wartość diagnostyczną zarówno EKG jak i MKG dla identyfikacji pacjentów zagrożonych częstoskurczem komorowym.
2
Content available remote Transformation of magnetocardiograms between different multichannel devices
EN
In Europe several types of multichannel SQUID-devices are applied for magnetocardiography (MCG). The technical parameters of these devices, such as the SQUID specification, gradiometer design, sensor configuration and covered sensor area, are different. The dependency of temporaI recordings of the cardiac magnetic field from these parameters is demonstrated by an example of cardiac measurement. The absence of a standardized measurement setup hampers the comparison of biomagnetic results in multicentric clinical studies. This contribution presents a method for comparison of signals recorded with different sensor systems. The recorded signals are modeled by means of a multipole source model, which is used in the next step to simulate the signals of a second system. The efficiency of the algorithm is demonstrated by a measurement of the heart magnetic field using two different multichannel SQUID-devices.
PL
Do pomiaru magnetokardiograrnów używane są w Europie różne wielokanałowe systemy pomiarowe o odmiennych parametrach konstrukcyjnych. Nie ma dotychczas standardu międzynarodowego dotyczącego tych systemów, co utrudnia porównywanie wyników uzyskiwanych w różnych ośrodkach badawczych. W pracy zaprezentowano metodę porównywania sygnałów mierzonych w różnych systemach przy wykorzystaniu modelowania multipolowego, która umożliwia symulowanie, sygnałów w dowolnie wybranym systemie pomiarowym. Skuteczność opracowanego algorytmu transformacji zilustrowano na przykładzie transformacji magnetokardiogramów dla dwóch różnych systemów wielokanałowych.