The aim of this work was to investigate the effect of partial substitution of Mn by Nb on structure and thermomagnetic properties in the (Mn, Nb)-Co-Ge alloy. The master alloys were prepared by arc-melting in an arc furnace with high purity of constituent elements under a low pressure of Ar. The prepared specimens were studied in as-cast state. The X-ray was performed by BRUKER D8 Advance diffractrometer with Cu Kα radiation. The analysis of the XRD pattern revealed coexistence of two orthorhombic phases with different lattice constants. The analysis of the temperature dependence of magnetizaton confirmed the XRD results and showed that produced material manifested two magnetic phase transitions corresponding to detected phases. The values of the Curie temperature were 275 and 325 K. The values of magnetic entropy change ∆SM equaled 3.30 and 2.13 J/(kg K), respectively for recognized phases. Biphase structure of produced material allowed to reach relatively high refigeration capacity 307 J/(kg). Moreover, the analysis of field dependences of magnetic entropy change (∆SM = CBn) allowed to construct temperature dependence of exponent n. The analysis of elaborated n vs. T curve confirmed biphasic structure of produced material.
EN
In the XXI century, magnetic measurements are widely used in many diverse applications. In this paper, we present the practical application of magnetic measurements in the Helmet Mounted Cueing System (HMCS) on board military aircraft . We start with the research problem and proposed solutions (idea). Next, the theoretical basis of the helmet’s system operation are described. Herein, we include the characteristics of the Earth’s magnetic fi eld and the modeling of this (WMM 2015, IGRF 12, EMM2017), as well as the theory of magnetic fi eld distribution as generated in fl at coils, Helmholtz coils and anti-Helmholtz coils. In the later detailed part, we describe the metrological aspects of HMCS applications and the characteristics therein of diff erent magnetometers used in the tests, plus example test results. Finally, we describe ongoing research, while in the summary, we present further research possibilities and potential directions of research in the avionic implementation of magnetic phenomena in HMCS systems.
3
Content available remote Magnetization measurements in circle-shaped samples of typical dynamo steel sheets
EN
The paper describes a significant modification of the measurement method of the rotational magnetization in which circle-shaped samples of dynamo sheets are used. In the modified method, additional packages of sheet samples allow us to achieve a more uniform distribution of the magnetic field in the examined sheet sample with respect to conventional measurement methods using circle-shaped samples. Additionally, this paper includes the measurement verification of the equations of the magnetic field distribution which take into account a model of the rotational magnetization in typical dynamo sheets.
PL
W artykule przedstawiono istotną modyfikację metody pomiarów przemagnesowania obrotowego, w której wykorzystywane są próbki blach prądnicowych w kształcie kołowym. W zmodyfikowanej metodzie dodatkowe pakiety próbek blach pozwalają uzyskać bardziej jednorodny rozkład pola magnetycznego w badanej próbce blachy w porównaniu z dotychczasowymi metodami, w których wykorzystywane są kołowe próbki blach. Dodatkowo, w artykule przedstawiono weryfikację pomiarową poprawności równań rozkładu pola magnetycznego, w których uwzględniono model przemagnesowania obrotowego typowych blach prądnicowych.
PL
Austenityczne stale są wykorzystywane do wykonania kołpaków wirników generatorów oraz bandaży, a także na bandaże do transformatorów i nakrętki. Takie stale powinny charakteryzować wysoka oporność, przenikalność magnetyczna mniejsza niż 1,3 mi r i wysoka wytrzymałość mechaniczna. Te właściwości nie powinny się także zmieniać pod wpływem obciążenia mechanicznego i cieplnego. Ze względu na nietrwałość austenitu niklowego, część niklu zastępuje się manganem. W artykule przedstawiono wyniki badań stabilności austenitu chromowo-manganowego w eksploatowanych kołpakach wirników generatorów. W chwili obecnej ocena przydatności kołpaków do dalszej eksploatacji oparta jest na badaniach ultradźwiękowych. Pomiary magnetyczne polegające na detekcji niestabilności austenitu w korelacjach mechanicznych i termicznych są alternatywą dla pomiaru tłumienia fali ultradźwiękowej, a ponadto dają pełniejszy obraz wyeksploatowania kołpaków.
EN
Austenitic (non-magnetic) steels are used in construction of generator rotors retaining rings and bandages as well as transformers` bandages and bolts. Such steels should be characterized by high specific resistance, magnetic permeability less than 1,3 mi r and high mechanical strength. In addition, these properties should not change due to possible mechanical and thermal load conditions. Since nickel austenite (gamma -> alfa), is not durable, some nickel is exchanged for manganese. The paper presents results of investigating stability of chromicmanganic austenite of used rotor retaining rings. At present the assessment of retaining rings, technical condition and their serviceability is conducted by ultrasonic wave attenuation tests. The magnetic measurements based on the detection of the instable austenite, which in the mechanical and thermal correlations constitute an alternative for the diagnostic testing and moreover they provide more complete picture of the retaining ring exploitation.
EN
The national project concerning development of technology of next generation applied electromagnetic machinery was founded in Oita under the name of "Oita Prefecture Innovative JST (Japan Science and Technology Agency) Research Program". In this paper, outline of this project is introduced and the applied technology based on vector magnetic properties is described. Many kinds of measurement equipment and systems were newly developed for this project. Some of them are presented in the paper.
PL
Przedstawiono główne wyniki realizacji projektu badawczego dotyczącego nowej generacji urządzeń elektromagnetycznych realizowanego w Oita University. Szczególny nacisk położono na opis właściwości wektorowych materiałów magnetycznych. Opracowano i opisano szereg nowych urządzeń i systemów pomiarowych.
EN
This paper introduces an original disc anisotropic structure which upgrades the performance of circular magnetic circuit. The stacking method consists in shifting by an angle â the axes of the rolling directions from one sheet to the following one. Two experimental setups are introduced. The first one is a comparative analysis for different â values on grain oriented laminations supplied by a single coil in order to determine the best â value in terms of iron losses and magnetizing current. The second experimental procedure is dedicated to measure and to analyze the 3D flux distribution.
PL
W artykule przedstawiono dyskową strukturę anizotropową, która poprawi własności kołowego magnetowodu. Sposób składania magnetowodu polega na przesuwaniu poszczególnych blach o kąt beta, w stosunku do kierunku walcowania blachy. Wykonano szereg pomiarów na różnych rdzeniach. Pozwoliło to określić optymalny kąt przesunięcia blach pozwalający zminimalizować straty w żelazie i zoptymalizować prąd magnesujący.
EN
We report on the X-ray powder diffraction and magnetic measurements of nanosize (La[0.7]Sr[0.3])[0.9]Mn[1.1]O[3] manganite. The nanoparticles were synthesized with use of co-precipitation method at different (800, 900 and 950[degrees]C) temperatures. Their crystal structure was determined to be perovskite-like with a rhombohedral distortion (the space group R 3c). The phase composition and specific surface nanopowders were determined. The average size of synthesized nanoparticles (from 32 to 88 nm) was estimated by both the method of low temperature adsorption of argon and X-ray diffraction measurements. All the nanosize samples show ferromagnetic-like ordering with close phase transition temperatures. Their magnetization decreases with reducing the particle size. The decrease of magnetization with decreasing particle size is due to increasing the surface contribution to magnetization. The magnetic entropy was shown to increase with increasing applied magnetic field and to be smaller for the small particles.
PL
W artykule przedstawiono wyniki pomiarów dyfrakcji rentgenowskiej oraz uzyskanych metodą magnetometryczną nanorozmiarowego manganitu (La[0.7]Sr[0.3])[0.9]Mn[1.1]O[3]. Próbki otrzymano metodą zol-żel w następujących temperaturach: 800, 900 i 950[stopni]C. Wszystkie próbki krystalizują w układzie romboedrycznym (grupa przestrzenna R 3c). Średni rozmiar ziaren (od 32 do 88 nm) określono za pomocą rentgenowskiej dyfrakcji proszkowej oraz metodą niskotemperaturowej adsorpcji argonu. Wszystkie próbki wykazują ferromagnetyczne uporządkowanie z bliskimi temperaturami przejścia fazowego i ich namagnesowanie maleje wraz ze zmniejszaniem się rozmiarów ziaren. Zmniejszenie namagnesowania wraz ze zwiększaniem się rozmiarów ziaren jest spowodowane wzrostem wkładu powierzchni ziaren do namagnesowania. Magnetyczna entropia rośnie wraz ze wzrostem pola magnetycznego i jest mniejsza dla małych ziaren.
8
Content available remote Measurement of core loss in single sheet tester
PL
Straty mierzone testerem SSTz pośrednim magnesowaniem (gdzie próbka jest magnesowana za pośrednictwem rdzenia z cewkami magnesującymi) nie zawsze korespondują ze stratami mierzonymi testerem o bezpośrednim magnesowaniu (gdzie próbka jest umieszczona wewnątrz cewek magnesujących). W obu typach testerów czujniki H i B mają szerokość porównywalna z wymiarami próbki. Straty mierzone testerem o magnesowaniu pośrednim wykorzystującym zbyt małe czujniki różnią się od strat mierzonych testerem o bezpośrednim magnesowaniu.
EN
The core loss measured with the indirect magnetizing single sheet tester (SST) (in which a sample is placed between yokes and is indirectly magnetized by the yokes magnetized by magnetizing coils) roughly corresponds with that measured with the direct magnetizing SST used as standard (in which a sample is placed inside a magnetizing coil and is directly magnetized by the magnetizing coil). Both the SSTs have the B coil and the H coil whose widths are the same as the sample width. However, the core loss measured with the indirect magnetizing SST using the small size of the B coil and the H coil is much different from that measured with the direct magnetizing SST.
9
Content available remote 2D magnetic measurements under 1D stress
EN
This paper describes recent development of 2D magnetic measurements under externally applied 1D stress. The measurement setup allows a broad range of 2D alternating and rotational magnetic measurements in laminated electrical steels. The mechanical stress ranges from elastic compression to plastic tension up to destruction. The automatic feedback control allows carrying out a broad range of strictly controlled magnetic measurements. Typical grain-oriented and non-oriented electrical steels are investigated at 2D alternating and rotational magnetizations.
PL
Przedstawiono dwuwymiarowe badania właściwości magnetycznych materiału poddanego jednosiowym naprężeniom. Stanowisko pomiarowe umożliwiało badania dwuwymiarowe laminowanych blach elektrotechnicznych przy wymuszeniu osiowym i rotacyjnym. Naprężenia mechaniczne zawierały się między elastycznym ściskaniem, a plastycznym rozciąganiem aż do zniszczenia materiału. Automatyczne sprzężenie zwrotne pozwalało na realizowanie założonych warunków magnesowania. Badano typowe blachy anizotropowe i izotropowe przy magnesowaniu osiowym i rotacyjnym.
PL
W artykule przedstawiono szkic metody całkowo-brzegowej zastosowanej do obliczeń wielkości magnetycznych płaskich magnesów cylindrycznych, charakteryzujących się dużymi wartościami koercji. Podano także wyniki pomiarów weryfikujących tę metodę.
EN
An outline of a boundary-integral approach applied for computation magnetic quantities of disc permanent magnets that are characterized by important coercivity is presented. Test results that were performed in order to verify the results of calculation are given.
EN
The influence of cross section size (in range of 10-50mm2) and geometry of magnetic cores made of dielectromagne and iron powders on their magnetic properties is presented in the paper. For this purpose, two kinds of iron powders v, different composition were measured in the range of frequencies 50 - 800Hz.
PL
Opisano system pomiarowy FERROMETR zbudowany w oparciu o komputer wyposażony w kartę akwizycji danych. System współpracuje z przetwornikiem prąd-napięcie oraz wzmacniaczem mocy i pozwala wyznaczyć kompleksowe parametry badanego materiału ferromagnetycznego. Oprogramowanie systemu umożliwia wyznaczenie parametrów obiektu w funkcji czasu oraz amplitudy i częstotliwości sygnału testującego w zakresie (10 ... 1000) Hz. Oprócz wyznaczenia charakterystyk parametrów badanej próbki system pozwala również opcjonalnie na pomiar indukcji lub stratności w wybranych punktach natężenia pola dla określonej częstotliwości.