Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  magnetic field strength
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Manganese carbonate ore belongs to weakly magnetic minerals, and its co-associated minerals are mainly non-magnetic minerals, which can be separated from gangue minerals at high magnetic field intensity. However, manganese grade and recovery of magnetic separation concentrate of manganese carbonate ore are low in actual production. Therefore, the influences of manganese carbonate particle size, magnetic field intensity, volume susceptibility, pulse stroke, pH, and other factors were studied. The optimal test conditions for manganese carbonate ore recovery by high-gradient magnetic separation were predicted through the calculation results. The results show that the particle radius of manganese carbonate is 0.020 mm, the pulse impulse time is 200 r/min, and the magnetic field intensity is 0.9 T. The optimum condition test was carried out with Qianbei manganese carbonate ore as the material. The test results show that the optimum conditions are the particle radius of 0.074-0.019 mm, pulse impulse time of 200 r/min, and magnetic field intensity of 1.2 T. The reason for the deviation is that the actual ore has a fine distribution particle size, many associative bodies, complex composition, and serious agglomeration, resulting in variable particle volume susceptibility. The capture yield increases with the increase of magnetic field intensity and volume susceptibility but decreases with the increase of pulse. The lower the surface potential of manganese carbonate, the higher the recovery of manganese carbonate. The grade of manganese concentrate was 19.06% and the recovery was 76.85%. Mixed manganese concentrate with a grade of 18.04% and recovery of 87.14% was obtained by adding drugs and changing the grinding method.
EN
The ‘GlidArc’ plasma reactors and ‘DBD’ reactors are used for the production of non-thermal plasma. Reactors generate electric discharges. They are the source of plasma and electromagnetic emission too. Institute of Electrical Engineering and Electrotechnologies has several installations of plasma reactors. The article presents the values of measured E and B in the range of very low frequencies. Values were compared with valid national norms. As a result of the analysis, operation of the reactors does not cause danger to the personnel.
4
PL
Wskazano na możliwe korzyści technologiczne wynikające z oddziaływania poprzecznego pola magnetycznego na łuk spawalniczy. Opisano efekty fizyczne powstające podczas odchylania kolumny łukowej. Dokonano przeglądu modeli i charakterystyk łuku w stałym, zmiennym, jednorodnym i niejednorodnym polu magnetycznym uformowanym przez wzbudnik indukcyjny. Zaproponowano strukturę układu sterowania urządzenia wykonującego proces technologiczny za pomocą odchylanego łuku elektrycznego.
EN
The study indicates possible technological benefits of the influence of transverse magnetic fields on welding arcs. Physical effects occurring during arc column deflection have been described. A review of models and characteristics of the arc in constant, variable, homogeneous and inhomogeneous magnetic fields formed by the inductor has been done. The structure of the control system of the device used for conducting technological processes by means of transverse magnetic field has been proposed.
PL
W artykule zaprezentowano obwód elektromagnetyczny przeznaczony do magnesowania magnesów trwałych. Przedyskutowano problemy projektowe oraz pokazano model obliczeniowy magneśnicy. Zaprezentowano rozkład natężenia poła magnetycznego w przestrzeni roboczej magneśnicy oraz pokazano indukcję magnetyczną w poszczególnych częściach obwodu elektromagnetycznego. Przedyskutowano wpływ strumienia rozproszenia na uzyskiwaną wartość natężenia pola magnetycznego w szczelinie magneśnicy. W artykule zaprezentowano również obliczeniowe przebiegi prądu i napięcia w obwodzie magneśnicy podczas rozładowania źródła energii elektrycznej. Przedyskutowano możliwości osiągnięcia wyższego natężenia pola magnetycznego w przestrzeni magnesu podczas procesu magnesowania.
EN
The electromagnetic circuit assigned to magnetize permanent magnets was presented in the article. Design issues and possibilities of magnetizer were discussed and analytical model of magnetizer was shown. A schedule of the magnetic field strength was expressed in the air gap of magnetizer and it was shown the electromagnetic induction in individual parts of power circuit. The influence of the leakage inductance on magnetic field strength value inside the gap of magnetizer was discussed. The computational temporary courses of voltage and current in the magnetizing coil during the process of discharge of electric generator were presented. Results of calculations and simulations were displayed. It was discussed the possibilities of accomplishing of the greater value of magnetic field strengths in the space of magnet during the magnetizing process.
PL
W artykule przedstawiono rozkłady natężenia pola magnetycznego niskiej częstotliwości występujące w lokalach mieszkalnych usytuowanych w sąsiedztwie wnętrzowych stacji transformatorowych 15/0,4 kV. Zwrócono uwagę na możliwość przekroczenia wartości dopuszczalnej tego natężenia pola w środowisku ogólnie dostępnym w wyniku niewłaściwego usytuowania kabli niskiego napięcia wewnątrz stacji transformatorowej. Zaproponowano rozwiązania pozwalające w istotny sposób zmniejszyć jego wartości.
EN
Distributions of magnetic field intensity of low frequency for dwellings located in vicinity of 15/0,4 kV indoor transformer sub stations are presented in this paper. It is shown that improper installation of low voltage cables can result in crossing the boundary values of the magnetic field intensity in surrounding are a open to the public. Solutions to limit the values of the magnetic field strength are proposed in the paper.
PL
W pracy rozważane są cewki o uzwojeniu cylindrycznym jednowarstwowym. Korzystając z prawa Biota-Savarta wyprowadzono zależności opisujące rozkład pola magnetycznego pojedynczego zwoju kołowego. Na tej podstawie sporządzono wykresy istotnych składowych na pewnych charakterystycznych powierzchniach. Po uwzględnieniu osobliwości funkcji rozkłady te aproksymowano wielomianami. Na podstawie uzyskanych zależności opracowano algorytm do wyznaczania wartości indukcyjności cewki jednowarstwowej. Dla sprawdzenia algorytmów porównano indukcyjność obliczoną i zmierzoną dla kilku cewek. Uzyskano dobrą zgodność wyników.
EN
The paper deals with a single-layer coil model. The integral formulas of the magnetic field components distribution have been obtained basing on the Biot-Savart law for circular conductor. After numerical integration the components magnetic field were calculated for some characteristic surfaces and it's diagrams were drawn. Taking into account the singularities at the components function were approximated using polynoms and the distribution of the magnetic stream components were calculated. In the next, the algorithm of the single layer coil were described. The algorithm were verified for a few inductances, which inductivities were measured. The result of the calculations and measurements are very close.
8
Content available remote Badanie zmian tła magnetycznego w otoczeniu
PL
W pracy przedstawiono wyniki badań zmiennych pól magnetycznych w zakresie bardzo niskich częstotliwości ELF (Extra Low Frequency). Stwierdzono, że pola magnetyczne w otwartej przestrzeni są niższe niż mierzone w mieszkaniach. W niektórych miejscach wartości natężenia pola magnetycznego (lub wektora indukcji magnetycznej) były porównywalne (lub większe) do wartości granicznych (0,1 - 0,2 µT) występujących w opracowaniach epidemiologicznych. Wiedza ta jest istotna przy ustalaniu dopuszczalnych ekspozycji dla całej populacji w zakresie niskich częstotliwości zmian pola elektromagnetycznego.
EN
The results of an extra Iow frequency (ELF) magnetic field survey in Rzeszów urban area, are presented. The average field levels in the open area are lower than measured in domestic conditions. In some places the magnetic field strength (or magnetic flux density B) proved to be comparable (or higher) to the cut - off point (0,1 - 0,2 µT) used in many epidemiological studies. This knowledge is very important for a complete definition of general public exposure to the electromagnetic field in Iow frequency range.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.