Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  lutetium
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Post-recoil thermal annealing study at different temperatures for different intervals of time of the recoiled isotopes 169Yb, 175Yb, 177Lu, 166Ho, and 153Sm resulting from the nuclear reactions 168Yb(n,gamma)169Yb, 174Yb(n,gamma)175Yb and 176Yb(n,gamma)177Yb → 177Lu, 165Ho(n,gamma)166Ho, 152Sm(n,gamma)153Sm, respectively in different organometallic compounds Yb(OCC(CH3)3CHCOC(CH3)3)3, Ho(OCC(CH3)3CHCOC(CH3)3)3, (C5H5)3Ho, and (C5H5)3Sm were carried out. The thermal annealing behaviors of 177Lu, 169Yb, 175Yb, 166Ho, and 153Sm were found to be different in the compounds under investigation. The differences in the patterns of the obtained isothermal curves were discussed. Depending on the post- -recoil thermal annealing manner the reactions taking place during thermal annealing were suggested.
EN
Preparation of 5,7-dichloroquinolinc-8-ol functional!zed naphthalene, a solid reagent for quantitative preconcentration of Nd, Eu and Lu from diluted aqueous and synthetic seawa-tcr solutions in the pH range of 8.0 š 0.2 has been described. Solid mixture enriched with the analyzed metal ion and containing the solid phase cxtractant was dissolved in 5 mL of DMF. After that, the Rare Earth Element (REE) content was established by Flame Atomic Absorption Spectrometry. Calibration plots were rectilinear over the ranges 0-1 800, 0-150 and 0-1300 μ.g of Nd, Eu and Lu, respectively present in 1.0 L of the aqueous solution. Five replicate determinations of 100 μg of Nd, Eu or Lu present in 1.0 L of the sample solution were performed. Average absorbance values equalled to 0.013, 0.13 and 0.015, respectively. The corresponding relative standard deviations were: 2.5, 1.8 and 2.4%. Detection limits (expressed as 3 times the standard deviation of a blank) and enrichment factors were found to be 40μ L-1 and 200, 4.0 ug L-1 and 200, and 30 μg L-1 and 200 for Nd. Eu and Lu, respectively. Nd, Eu and Lu contents in scawater could be quantified by ICP-MS after prior preconcentration of the analytes applying the proposed procedure.
PL
Opisano preparatykę stałego odczynnika do wstępnego zatężania Nd, Eu i Lu z rozcieńczonych roztworów wodnych lub syntetycznej wody morskiej w zakresie pH: 8 š 0.2, którym jest jednorodna mieszanina naftalenu z 5,7-dichloro-8-hydroksy-chinoliną. Odczynnik wzbogacony zatrzymanymi jonami metali rozpuszczano w 5 mLDMF i oznaczano pierwiastki ziem rzadkich (REE) za pomocą płomieniowej atomowej spektrometrii absorpcyjnej. Krzywe kalibracyjne były prostoliniowe w zakresach stężeń: 0-1800, 0-150, 0-1300 &mu.g w l L roztworu. Średnie wartości absorbancji wynosiły odpowiednio: 0.013, 0.13 i 0.015 a odpowiadające im odchylenia standardowe: 2,5, 1,8 i 2.4%. Granice wykrywalności (określone jako trzykrotna wartość odchylenia standardowego ślepej próby) wynosiły odpowiednio: 40, 4,0 i 30 μg L-1 dla Nd, Eu i Lu. Współczynniki wzbogacenia wynosiły 200 dla wszystkich trzech pierwiastków Nd, Eu i Lu. Opracowaną metodę wstępnego zateżania REE w połączeniu z ICP-MS zastosowano także do oznaczania tych pierwiastków w wodzie morskiej.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.