Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  luminol
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available Chemiluminescencja – tajemnice zimnego świecenia
PL
W artykule opisano wybrane zagadnienia dotyczące procesu chemiluminescencji: omówiono jej mechanizm oraz warunki powstawania. Zaprezentowano najbardziej wydajne systemy chemiluminescencyjne. Przedstawiono zastosowania chemiluminescencji w badaniu próbek w fazie ciekłej, gazowej i stałej.
EN
In this paper, selected issue of chemiluminescence process has been presented. The mechanism and requirements for chemiluminescence emission have been considered. The most efficient chemiluminescence systems have been discussed. Chemiluminescence application as an analytical tool in the liquid, gas and solid phase have been presented.
EN
Although much work has been conducted to quantify the long-term physiological effects of psychological stress, measures of short-term, low-level stress have been more elusive. This study assessed the effect of exposure of volunteers to a mild, brief, psychologically stressful event, on the functional ability of leukocytes in whole blood to respond to phorbol 12-myristate 13-acetate (PMA) in vitro. Volunteers operated a car electric window and adjusted it to 4 pre-determined positions. Between each operation the mechanism’s polarity was covertly altered (group B) or remained unaltered (group A). For each treatment group 10 different subjects provided capillary blood samples pre- and post-stressor. Using a chemiluminescent technique termed leukocyte coping capacity, the ability of leukocytes to produce reactive oxygen species (ROS) in vitro was assessed. ROS release differed significantly at 10 min post-stressor between treatment groups, suggesting exposure to acute psychological stress leads to a reduced ability to respond to bacterial challenge.
EN
A sensitive chemiluminescence method for determination of loratadine has been presented. The method is based on the inhibitory effect of loratadine on the chemiluminescence reaction between luminol and myoglobin. The decrement in chemiluminescence intensity changed linearly with the logarithm of loratadine concentration over the range 0.1 -100.0 ng mL-1(R-1 = 0.9992) with a detection limit of 0.03 ng L-1(3&sigma). At a flow rate of 2.0 mL min-1, the complete analytical process could be performed within 30 s including sampling and washing, with a relative standard deviation of less than 3.0% (n = 7). Without any pretreat-ment the proposed procedure was applied to the determination of loratadine in tablets, human serum, and urine samples with recoveries of 91.7-108.3%, 90.1-103.3%, and 94.6-107.6%, respectively.
PL
Przedstawiono czułą chemiluminescencyjną metodę oznaczania loratadyny. W metodzie wykorzystano hamujące działanie loratadyny na chemiluminescencję powstającą podczas reakcji między luminolem i mioglobiną. Natężenie chemiluminescencji zmniejszało się liniowo wraz ze wzrostem logarytmu stężenia loratadyny w zakresie 0,1-100 ng mL2 (R2 = 0,9992), a granica wykrywalności wynosiła 0.03 ng mL2 (3σ). Przy przepływie 2,0 mL min~' kompletne oznaczenie mogło być wykonane w ciągu 30 s (włączając próbkowanie i przemywanie), przy czym względne odchylenia standardowe wynosiło mniej niż 3% (n = 7). Metodę zastosowano do oznaczania loratadyny w tabletkach, we krwi ludzkiej i w moczu, bez wstępnego przygotowania; odzysk wynosił odpowiednio: 91,7-108,3%, 90, l-l 03,3% oraz 94,6-107,6%.
EN
A sensitive, simple, and rapid chemiluminescence method has been employed for monitoring of sub-nanogram level of vitamin C in human urine. The procedure was based on strong decrease of chemiluminescence by vitamin C in reaction with luminol and periodate. It has been found that quenching of chemiluminescence was linearly proportional to the logarithm of vitamin C concentration in the range of 0.1-100 ng mL-1. The analytical procedure, including sampling and washing, was completed within 0.5 min, giving an analytical throughput of 120 samples per hour. The limit of detection was 0.03 ng mL-1(3σ) and relative standard deviation was lower than 2.5%. The proposed method was successfully applied to the monitoring of excretion of vitamin C with human urine during 24 h after oral administration of tablets of vitamin C. Possible mechanism of chemiluminescence changes has been also discussed.
PL
Opracowano czułą, prostą i szybką metodę monitorowania witaminy C w ludzkim moczu na poziomie ułamków nanogramów. Opracowana procedura jest oparta na silnym obniżeniu chemiluminescencji w układzie luminol/jodan(VII) przez witaminę C. Stwierdzono, że spadek intensywności chemiluminescencji jest wprost proporcjonalny do logarytmu ze stężenia witaminy C w zakresie 0,1-100 ng mL-1. Procedura analityczna , włączając próbkowanie i mycie, może być przeprowadzona w ciągu 0,5 min, co daje wydajność 120 analiz na godzinę. Granicę wykrywalności określono na 0,03 ng mL-1 (3σ), a względne odchylenie standardowe było niższe od 2,5 %. Opracowana metoda została z sukcesem zastosowana do monitorowania wydzielania witaminy C z moczem w czasie 24 godz. po połknięciu tabletek.Możliwy mechanizm zmian chemiluminescencji był również dyskutowany.
5
Content available remote Flow through sensor for the chemiluminescence determination of thiamine
EN
A novel chemiluminescence (CL) sensor for thiamine combined flow-injection (FI) technology is presented in this paper. The analytical reagents, luminol and ferricyanide, were both immobilized on an anion exchange column. The CL signal produced by the reaction between luminol and ferricyanide, which were eluted from the column with the sodium phosphate injection, was decreased in the presence of thiamine. The decreased CL intensity was linear for thiamine concentration in the range from 0.2 to 4.0 nmol mL(-1); and the limit of detection was 66 pmol mL(-1) (3sigma). The whole process, including sampling and washing, could be completed in 2 min with a relative standard deviation of less than 3.0%. The sensor could be reused more than 400 times and has been applied for the determination of thiamine in pharmaceutical preparations and human urine samples.
PL
Opracowano nowy sensor do oznaczania tiaminy w przepływie oparty napomiarze chemiluminescencji (CL). Reagenty: luminol, heksacjanożelazian(III) potasu sąpoczątkowo związane na kolumnie anionowymiennej. Po wymyciu reagentów z kolumny wstrzykiwanym fosforanem sodu, w wyniku reakcji pomiędzy luminolem i heksacjanożelazianem powstaje sygnał CL, który w obecności tiaminy jest osłabiony. Zmiana sygnału CL jest proporcjonalna do stężenia tiaminy w zakresie od 0.02 do 4 nmol mL(-1). Granica wykrywalności, liczona jako 3-krotne odchylenie standardowe, wynosi 66 pmol mL(-1). Cały proces analityczny można wykonać w 2 min, a sensor może być użyty przynajmniej 400 razy. Opracowany sensor został zastosowany do oznaczania tiaminy w preparatach farmaceutycznych i w moczu.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.