This paper presents accurate fault detection and location using wavelet based on Clarke’s transformation. This study was done using Clarke’s transformation method to convert current phase (three phase) signal into a two-phase current alpha and beta (current mode). The proposed method introduced the mode current to transform the signal using discrete wavelet transform (DWT) and was utilized to obtain the wavelet transform coefficients. Analysis was also conducted for other mother wavelets. The most accurate parent was wavelet Db8, with the fastest time of detection and the smallest error, whereas the largest error was found in Coil4 parent wavelet. The result for proposed method was compared with Db4, Sym4, Coil4 and Db8 and found to be very accurate.
PL
W artykule opisano dokładną metodę wykrywania awarii w sieciach przesyłowych bazująca na falkowej transformacie Clarka. Sygnał trójfazowy jest przekształcany do postaci dwufazowej Za najbardziej się do tego celu nadająca uznano falkę Db8 z najszybszym czasem wykrywania i najlepszą dokładnością. Wyniki porównano z innymi typami falek.
EN
Locating a faulty section of the high impedance fault (HIF) in a power system network is a major challenge especially for a distribution network. This is due to the effect of the complexity of the distribution network such as branches, non-homogenous lines and high fault impedance that results in variation of fault locations. In this paper, analysis of fault locations using Discrete Wavelet Transform-based Multi-Resolution Analysis (MRA) has been proposed. A three-phase voltage signal measured at the main substation is analyzed to locate the high impedance fault. The 1st, 2nd and 3rd levels of detailed coefficient resolution for each phase were used for the classification of fault locations using the proposed method. The simulation was conducted on a 38-node distribution network system in a national grid in Malaysia using PSCAD software. The proposed method has successfully determined the actual fault location of a high impedance fault.
PL
W artykule przedstawiono analizę metody lokalizacji awarii w sieci energetycznej, wykorzystującej analizę wielo-wynikową (ang. Multiresolution Analysis), opartą na dyskretnej transformacji falkowej. Analizie poddawany jest sygnał pomiarowy napięcia trójfazowego w podstacji. Przeprowadzono badania symulacyjne w programie PSCAD na systemie dystrybucji energii elektrycznej o 38 korzeniach w malezyjskich państwowych sieciach energetycznych.
3
Content available remote Research of the fault location method of distribution network
EN
The rough set theory is used to realize the automatic fault location method of the rural power distribution network. The decision table of the distribution network fault location is based on the fault complaints information. It is automatically formed by distribution network topology. Then the decision table is property reduced based on identifiable matrix. Finally improved value reduction method is used to form the fault diagnosis expert knowledge uniformly. Combined with the GIS platform, it designs the application program of the fault location and realizes the visual fault localization.
PL
W artykule zaproponowano wykorzystanie teorii zbiorów przybliżonych w tworzeniu metody lokalizacji awarii w sieci elektroenergetycznej na terenie wiejskim. Metoda bazuje na drzewie decyzyjnym, w którym zawiera informacja o zgłoszeniach awarii. Opracowany algorytm redukcji wielkości drzewa, w połączeniu z platformą Systemu Informacji Geograficznej (ang. Geographic Information System – GIS), pozwala na dokładne określenie miejsca awarii.
EN
With the widely use of traveling wave fault location equipment (TWFLE) in power grid, network-based traveling wave fault location (NBTWFL) method has been proposed. To ensure the effectiveness and economy of NBTWFL method, based on the principle of characteristic nonsingular set, an optimal placement algorithm of TWFLE is proposed in this paper. The corresponding NBTWFL method based on maximum nonsingular subset, additional installation plan of TWFLE and some other related problems are also discussed in this paper.
PL
W artykule opisano metodą wykrywania awarii w sieci elektroenergetycznej na podstawie analizy fali wędrującej. Proponowane rozwiązanie bazuje na klasycznym algorytmie wykrywania fali wędrującej, w którym zastosowano niesingularne wartości własne. Pozwoliło to na optymalizację rozmieszczenia urządzeń do wykrywania awarii.
5
Content available remote Travelling Wave Single End Fault Location Method based on Network Information
EN
The single end travelling wave fault location method is usually difficult to discriminate the reflection wave of fault point. This paper employs wavelet transform to detect possible fault point in power system. Using the real time network topology and possible fault point, the travelling wave propagation waveform can be constructed. By comparing the constructed waveforms and real recorded waveform, the reflection wave of fault point can be identified. The simulation verifies its correctness, and the field application proves the feasibility of this method.
PL
W artykule zaprezentowano metodę lokalizacji możliwych awarii w sieci energetycznej na podstawie Transformaty Falkowej. Wyniki badań symulacyjnych i eksperymentalnych potwierdzają skuteczność metody.
EN
Theoretical basis. Finding the failure point with the use of seismic geophones and a correlator. Method of measuring the power of acoustic pressure.
EN
Changes in characteristics of electric and magnetic conductivrty of a ground center caused by liquid flow from an injured pipeline. Electric methods - electro-resistance measuremenls, method of gradient potenlial. Electromagnetic methods - finding the breakdown place with the useof georadar. Advanlagesof each method.
8
EN
Surface temperature measurements over heating installations. Influence of materials' and external factors' characteristics on the temperature range measurement in the measured area. Measuring equipment.
PL
Obecne regulacje prawne określają coraz bardziej rygorystycznie wartości parametrów jakości i niezawodności dostawy energii elektrycznej. Przy wykorzystaniu narzędzi programistycznych stworzona została baza informacji o sieci w stanie pracy normalnej i zakłóceniowe pozwalające na identyfikację szczegółową zakłóceń. Gromadzone dane są przetwarzane w bazie danych (SQL) i podlegają obróbce statystycznej. Na podstawie danych historycznych tworzone są procedury wspomagające lokalizację miejsca zakłócenia z uwzględnieniem wpływu różnych czynników.
EN
Polish decree determines the quality and reliability parametrs of power supply. Therefore, it is purposeful to create a databases of disturbances in normal and postfailure conditions of power distribution network with use of programming tools. The collecting data are processing and analysed in SQL database. Procedure of locating a failure are designing used collected historical data and informations of power distribution network.
PL
Zasadniczy wpływ na czasy przerw w zasilaniu ma sprawność lokalizacji uszkodzonego odcinka linii zasilającej. Artykuł przedstawia analizę czynników wpływających na sprawność lokalizacji uszkodzeń w miejskich sieciach kablowych. Przedstawiono wybrane dane statystyczne potrzebne do takiej analizy.
EN
The principal influence on outages has the efficiency of damaged power line section locating. This article presents the analysis of factors influencing on efficiency of failure locating in cable networks on urban areas. The chosen statistic data, which are necessary for such analysis, were proposed.