Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  loadability
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Using SVC to Improve Voltage Stability of the Ghana Power Network
EN
This paper forms part of an ongoing system development of the Ghanaian power network. Preliminary studies have shown that the northern sector is venerable to voltage instability which has led to the proposed installation of STATCOM at Tamale. It is therefore necessary to assess the performance of the device when put in operation. Comparison had therefore been made between the use of STATCOM and Fixed Compensator. Line and generator contingencies as well as small signal disturbances analysis had been carried out. Voltage stability is improved with the installation of STATCOM as well as reduction in voltage oscillation during transient. Loadability limit of the system is also increased. Further evaluation targeted at the inter-tie with Burkina Faso has been proposed.
PL
W artykule opisano prace nad rozwojem sieci elektroenergetycznej Ghany. Badania wstępne wykazały, że północny sektor sieci jest wpływa na niestabilność napięcia. Jako rozwiązanie zaproponowano instalacje kompensatora STATCOM. Dokonano jego porównania z klasycznymi filtrami biernymi, zarówno pod kątem potencjalnych awarii w sieci, jak i niewielkich zakłóceń. Proponowane rozwiązanie zwiększa stabilność napięcia oraz możliwości obciążeniowe.
PL
W artykule przedstawiono zagadnienie opracowania programu numerycznego do wyznaczania temperatur oleju i uzwojeń oraz obciążalności przesuwników fazowych, które znajdują zastosowanie do regulacji przesyłu mocy w sieci elektroenergetycznej. Ponadto przedstawiono krótkie porównanie z transformatorami energetycznymi, schemat elektryczny i zależności wykorzystywane do obliczania prądów w uzwojeniach.
EN
A problem of designing computer program for estimating oil and winding temperatures and load abilities of phase shifting transformers (PST) is considered in this paper. PSTs are useful as a tool for controlling power flow in a grid. Additionally there was shown a short comparison between power transformers and PSTs, a connection diagram and some equations used in electrical model of PST.
3
Content available remote Effect of voltage and current distortion on power transformers loadability
EN
The admissible transformer load is limited by its electrical, mechanical and thermal withstandability, and by its insulation ageing rate. The transformer has certain ratings, for instance nominal powers and nominal winding currents. Transformer operation under nominal load is possible only under certain circumstances. Due to no-load and load losses, the current flowing along the windings produces heat which raises temperature of windings, oil and cellulose insulation, as well as construction parts. Certain temperature values, however, must not be surpassed because of a gas bubble generation hazard that may be sites of PD or may provoke an excessive ageing of the cellulose insulation within a longer operation time. Under a fixed load, the temperatures in the transformer depend on ambient temperature, i.e. the transformer may operate normally or may be overloaded depending on the ambient conditions. The winding temperatures make the criterion in this case because it is assumed that the oil temperature does not exceed that of thewinding hot-spot. The heating of the transformer is chiefly due to the load losses being dependent on the current squared. Thus a decrease in the current value ought to cool the unit. It may therefore be concluded that if the transformer is to operate normally under an ambient temperature higher that the one it was designed for, its load must be lowered, i.e. its loadability decreases when the ambient temperature increases. Under the ambient temperature lower than that assumed by the designer, the transformer may, obviously, be overloaded. The overloading criterion may in this case make the temperature or the admissible current value based on mechanical stress. The transformers are usually overloaded a little but there are also units designed to be overloaded up to 200% of their rated power within a short period [9]. Algorithms of temperature computations in the transformer together with appropriate formulae were given in standards [3] and [4]. They were made use of in the DTR programme with author`s own algorithms describing the optimum load selection, the above mentioned limitations being taken into account. The standards concerning power transformer loadability [3] and [4] offer formulae and simple algorithms enabling computing oil and winding temperatures at a given current and an ambient temperature. The real power transformer, however, is an object much more complex than the one assumed in those simplified algorithms. The transformer has at least two windings, is equipped with voltage regulation devices - often more than one, and may have various winding configurations round the core. The numerical programme must in consequence be much more complex than the one offered by the standards [3], [4].
PL
Celem pracy było opracowanie programu numerycznego, który uwzględniając możliwie pełny zakres zagadnień związanych z teorią i budową transformatorów energetycznych, będzie stanowił praktycznie użyteczne narzędzie dla operatora systemu energetycznego, pozwalając mu świadomie obciążać (przeciążać) transformator w stanach awaryjnych, informując go o temperaturach tzw. punktów gorących (hot spots) oraz zliczając ubywający czas życia izolacji papierowo-olejowej. Jednocześnie naukowy cel pracy polega na tym, że tak opracowany program numeryczny pozwoli na cały szereg analiz numerycznych dotyczących wpływu różnych czynników (np. zmienna temperatura otoczenia, zmienna krzywa obciążenia, zmienność napięcia zasilania, odkształcenie napięcia i prądu, stan układu chłodzenia, położenie przełącznika zaczepów, konstrukcja transformatora itp.) na temperatury gorących punktów w poszczególnych uzwojeniach, a tym samym na obciążalność transformatora, czy czas życia izolacji. Podobne analizy są dostępne w literaturze, jednak z pominięciem wielu czynników, które proponowany program uwzględnia. Tezy pracy brzmią następująco: Teza I: Wykorzystując zależności podane w normach [6] i [9] oraz wiedzę teoretyczną dotyczącą teorii transformatorów energetycznych można zbudować uniwersalny program numeryczny służący do szacowania obciążalności krótkotrwałej i długotrwałej transformatora energetycznego z uwzględnieniem ograniczeń prądowych, temperaturowych i starzeniowych. Teza II: Wykorzystanie kompleksowego programu numerycznego uwzględniającego cały zestaw złożonych problemów związanych z konstrukcją i eksploatacją transformatora energetycznego pozwoli określić również wpływ wybranych parametrów jakości energii elektrycznej na obciążalność transformatora energetycznego o dowolnej konstrukcji.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.