EN
This paper presents application of Finite Element Method in designing of a vibration isolated object. A model of power generator of 113 MW was chosen for the analysis. Such the generator is used in one of power plants in Silesia district. Several frequency domain dynamic analyses aimed at assessment of influence of vibration isolation on acceleration level of the generator foundation were performed. Three different models of the generator were considered. For the purposes of verification of the obtained results measured vibration accelerations were used.
PL
W artykule przedstawiono zastosowanie metody elementów skończonych w projektowaniu obiektów wymagających zastosowania wibroizolacji. Jako model testowy wybrano generator o mocy 113 MW. Generator ten jest eksploatowany w jednej z elektrowni na Śląsku. Przeprowadzono kilka analiz dynamicznych w dziedzinie częstotliwości dla trzech różnych modeli, aby zweryfikować wpływ wibroizolacji na poziom przyspieszenia na podłożu. W przeprowadzonych badaniach wykorzystano również wyniki pomiarów przyspieszenia drgań.