This paper presents closed distributional solutions of bending problems for continuous thin-faced sandwich panels modeled by appropriate beams. Sandwich elements with any number and spacing of elastic supports, subjected to a uniform transverse segmental load or a temperature difference load, were analyzed. Calculations based on the proposed solution made it possible to show what effects the intermediate supports and their compliance have on the effort of the continuous sandwich panels and their connections to the framing. Examples are provided in which generalized formulas for intermediate support reactions and bending moments in two- and three-span beams subjected to a uniform transverse load or a temperature difference load along the beam’s whole length or part of its length are derived. The relationships between the above static quantities and the compliance of the intermediate supports or the extent of the segmental load are presented in the figures or the tables. Finally practical conclusions are drawn.
PL
Przedstawiono przykłady wadliwych ścian i dachów obudów z płyt warstwowych. Przyczyną niewłaściwego zachowania się tych obudów jest ich wykonywanie z wadliwych płyt warstwowych, a także błędy popełnione na etapie projektowania i wykonywania lekkiej obudowy. Omówiono zasady ustalania obciążeń oraz projektowania i wykonywania lekkiej obudowy z płyt warstwowych. Podano ogólne wnioski i zalecenia w odniesieniu zarówno do płyt warstwowych, jak i do połączeń tych ptyt z platwiami i ryglami ściennymi.
EN
Examples of defective building walls and roofs constructed from sandwich panels were introduced. The inappropriate behaviour of this cladding is caused by defective quality of sandwich panels and errors made during designing and execution of the light cladding. The principles of load establishing as well as of designing and execution of the light cladding from sandwich panels were discussed. The work was remarked by general conclusions and recommendations due to both sandwich panels and panels to purlins and wall girts connections.
EN
A distributional solution of the continuous sandwich panel (beam) bending problem is presented. Numerical analyses based on this solution were carried out in order to illustrate the effect of the spacing of intermediate supports and their compliance on the strain of continuous sandwich panels, and the joints fixing them to the steel framing. Two-, three- and four-span sandwich panels of different length, subjected to uniform transverse load or different temperature, were analyzed. New formulas for the critical state of elastic stability of lightly profiled faces of sandwich panels under bending, which determines the load-bearing capacity of the latter, were derived from the compressed face wrinkling condition. A bar compressed by a changing longitudinal force, interacting with a Winkler elastic foundation (representing the core), was adopted as the calculation model of the facing. The results of calculations done accordingly to Polish Standard, as well as using formulas provided by European guidelines and proposed formula were compared with the results of tests carried out on sandwich panels by the authors.
PL
Przedstawiono rozwiązanie w postaci dystrybucyjnej problemu zginania ciągłych płyt warstwowych jako odpowiednich belek. Dokonane na tej podstawie analizy obliczeniowe pozwoliły na zilustrowanie wpływu zarówno rozmieszczenia podpór pośrednich, jak i ich podatności, na wytężenie ciągłych płyt warstwowych i ich połączeń z konstrukcją wsporczą. Rozpatrzono przy tym dwu, trzy i czteroprzęsłowe płyty warstwowe o różnych długościach, obciążone równomiernie poprzecznie lub różnicą temperatury. Wyprowadzono nowe wzory na obliczanie naprężeń krytycznych stateczności sprężystej nisko profilowanych okładzin zginanych płyt warstwowych, decydujących o nośności płyt z warunku załamania (zgniecenia) ściskanej okładziny. Jako model obliczeniowy okładziny przyjęto pręt ściskany zmienną siłą podłużną, współpracujący ze sprężystym podłożem typu Winklera, odwzorowującym rdzeń. Na przykładach płyt warstwowych będących przedmiotem własnych badań doświadczalnych, dokonano odpowiednich porównań wyników eksperymentalnych z wynikami obliczeń według polskiej normy, a także wzorami z wytycznych europejskich i proponowanym wzorem.