Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  lateral expansion
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The problem related to the effect of the corner column load on the punching shear resistance of the slab was presented. Existing experimental studies on internal columns demonstrated that the column pressure could lead to an increase in the punching shear resistance. Because of different confinement conditions of corner column-slab connection joints, it is unclear if such an effect exists for corner columns. New experimental investigations were initiated to clarify this issue. They covered a total of three corner column-slab connection specimens – slabs with a thickness of 140 mm and a longitudinal reinforcement ratio ρl = 1.09% connected with columns of a cross-section of 200×200 mm. The only variable parameter was the column load equal to 500, 1000 and 1500 kN. A reduction of the slab load-carrying capacity of about 9% due to a three-fold increase in the column load was noted. Therefore, the effect of the column load turned out to be opposite to that observed for most previous tests on internal column-slab connections, which could have a result of a limited capacity of the slab reinforcement due to additional tensile forces from the lateral expansion of joint concrete. Comparison in the light of test results demonstrated, that EN 1992-1-1 procedure allowed for safe, yet conservative estimation of the punching shear resistance. An average ratio of experimental to theoretical load of 1.82 was obtained.
PL
W artykule przedstawiono zagadnienie wpływu obciążenia słupa narożnego na nośność płyty na przebicie. Dotychczasowe, nieliczne badania eksperymentalne dotyczące słupów wewnętrznych wykazały, iż nacisk słupa może prowadzić do zwiększenia nośności na przebicie. Z uwagi na odmienne warunki skrępowania węzłów skrajnych połączeń płytowo-słupowych konieczne było jednak zweryfikowanie tego efektu w odniesieniu do slupów narożnych. W tym celu wykonano i zbadano trzy modele połączeń płytowo-słupowych, wykonanych w skali. Wszystkie modele charakteryzowały się jednakową geometrią i zbrojeniem. Płyty o grubości 140 mm i stopniu zbrojenia podłużnego ρl = 1,09% połączone były ze słupami o przekroju 200×200 mm. Jedyny parametr zmienny stanowiło obciążenie słupa, równe 500, 1000 oraz 1500 kN. Wskutek trzykrotnego zwiększenia obciążenia słupa odnotowano zmniejszenie nośności na przebicie o około 9%. Efekt obciążenia słupa na nośność płyty okazał się zatem przeciwny do obserwowanego w przypadku większości badań połączeń wewnętrznych, czego przyczyny należy upatrywać w ograniczeniu nośności zbrojenia podłużnego płyty ze względu na odkształcenia poprzeczne betonu węzła. Porównanie wyników badań z obliczeniami według EN 1992-1-1 wykazało, iż procedura normowa pozwoliła na bezpieczne, aczkolwiek konserwatywne oszacowanie nośności modeli. Uzyskano bowiem średni stosunek nośności eksperymentalnej do teoretycznej równy 1,82.
EN
Structural performance of rectangular concrete section confined by squared spirals was investigated. Through the uni-axial compression test using concrete prisms with squared spirals and without longitudinal bars, the enhancement of strength and deformation capacity of rectangular concrete section was scrutinized. By the experimental observations on the properties of lateral expansion of concrete prism, a moment of reaching the axial peak stress in section was predicted in a good accuracy. Qualitative relationships between the structural performance (the enhancement of strength and deformation capacity) of concrete prism and confinement efficiency were studied. Also, for the effective use of normal- and high-strength lateral reinforcement, a design implication using the qualitative relationship of the tensile stress in lateral reinforcement at failure of concrete prism with parameters was proposed.
PL
W publikacji poruszone zostały kwestie związane z charakterem pękania metali, zdolności absorpcji energii dynamicznej i samohamowania pęknięć. Omówiono podstawy próby udarności metali i stopów sposobem Charpy’ego, z uwzględnieniem różnic w amerykańskim i europejskim wariancie próby. Podkreślono wady i zalety sposobów oceny ciągliwości przełomów udarnościowych opartych na udziale przełomu plastycznego SFA i rozszerzeniu poprzecznym LE. W dalszej części publikacji przedstawiono materiały spawalnicze firmy Metrode przeznaczone do zastosowań kriogenicznych oraz ich właściwości ze szczególnym uwzględnieniem KV i LE w temperaturze –196 stopni Celsjusza.
EN
In the Charpy impact test three key measurements be made – total absorbed energy, Shear Facture Area SFA and Lateral Expansion LE. However, although these three magnitudes have been available from the Charpy test, two of them SFA and LE have been just lately launched in Europe along with new standard EN ISO 148, which combines both American (ASTM E23) and European (EN 10045) regulations. In this paper principles of the impact tests and ductile-brittle fracture characterization are provided as well as comparison between American and European variants of the Charpy impact test. The second part covers specialist and the most demanding area for welding consumables for joining 304L and 316L stainless steel that are subject to service temperatures down to –196 centigrade. The dedicated range of controlled ferrite ‘CF’ consumables manufactured by Metrode is also described and some of the applications for which they been use are highlighted.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.