Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  laser-induced fluorescence
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available Laser based diagnostic system for spray measurements
EN
The paper discusses the capabilities of the laser diagnostic system for dispersed multiphase flows measurements, which was recently commissioned at the Institute of Heat Engineering (ITC) at Warsaw University of Technology. The system presented in the paper is multifunctional and is capable to use different measurements techniques such as shadowgraphy, Mie scattering (scattering on the gas-liquid interface) and LIF (laser induced fluorescence). It provides possibility of switching from one technique to another depending on the characteristics of the observed combustion/injection mixing process. The operational features are discussed in-detail. The study presents the required and possible system setups. Special attention was focused on the system components, which are needed for relevant measurement techniques. Moreover, the limitations of the measurement techniques are discussed and the example measurements are presented. The study shows that using different techniques extends the measurement capabilities of the system with minimum investment costs. This results from the fact that certain system components for different techniques are the same. Moreover, one can conclude that the system design allows certain measurement methods to be applied simultaneously, which results in synergy by making possible drawing more advanced conclusions on observed phenomena
EN
Field plants can be exposed to several stresses. Early detection of any change in plant health is important in order to undertake an action to restore its vitality. In this paper, a new approach towards characterization of nutritional lacks in wheat leaves of different varieties has been proposed. The developed procedure is based on a laser-induced fluorescence (LIF) imaging system, which allows scanning of emission intensity distribution over the sample surface. Importantly, the new technique is non-invasive and allows for in-situ field analysis of leaves, as the LIF system is housed in a laboratory vehicle. Detection is based on chlorophyll fluorescence-emission band ratios. It allows for the analysis of leaf surface and for the establishment of the relation between emission and the type of wheat variety. The measurements were made in test areas grown with different varieties of a particular wheat type, called long cycle wheat. The proposed technique provides an appropriate method of analysis of different wheat varieties with regard to irregular weather conditions in the investigated region.
PL
Rośliny gruntowe mogą być poddane różnym stresom. Ważne jest aby wcześnie wykrywać niekorzystne zmiany w zdrowiu roślin i przywracać im witalność. W tej publikacji zaprezentowano nowy sposób określania niedożywienia w liściach pszenicy różnego gatunku. Opracowana procedura jest oparta na obserwacji fluorescencji wzbudzonej laserem (LIF) co umożliwia rejestrowanie rozkładu intensywności emisji na powierzchni próbek. Nowa technika jest bezinwazyjna i pozwala na analizę in-situ w polu. Układ LIF umieszcza się w samochodzie. Detekcja jest oparta na pomiarze stosunku intensywności pasm fluorescencji chlorofilu. To pozwala na analizę powierzchni liścia i na ustalenie zależności między emisją i typem pszenicy. Pomiary wykonano w wybranych obszarach z uprawami szczególnego typu pszenicy zwanego pszenicą długi ego cyklu. Zaproponowana technika jest odpowiednią metodą analizy pszenic poddanych nietypowym warunkom pogodowym.
EN
The streamer observation and LIF detection of the NO molecules and OH radicals were performed during the steady-state positive DC corona discharge at atmospheric pressure. The time relationship between the regular streamer coronas, laser pulse, LIF signal and laser-induced streamer was explained for no time synchronization LIF measurement. Using the corona radical shower reactor, two-dimensional distributions of ground-state NO (X_2II) could be observed not only in the discharge zone but also both in the downstream and the upstream regions of the reactor. The presence of the ground-state OH (X_2II) and excited-state OH (A_2...) radicals in DC streamer discharge was also investigated. Moreover, the effect of electrohydrodynamic (EHD) flow on NO profiles in the reactor and ozone interference in OH LIF measurement were discussed. The obtained results sllOwed that the density of NO molecules decreased not only in the plasma region formed by the corona streamers and the downstream region of the reactor but also in the upstream region of the reactor. On the other hand, the ground-state OH radicals were generated and stayed mainly in the region where streamers propagated betweell the electrodes.
PL
Omówiono zagadnienia dokładności pomiarów spektroskopowych niezbędnej do udoskonalenia semiempirycznych metod opisu struktury elektronowej atomów złożonych. Przedstawiono stosowane w Katedrze Inżynierii i Metrologii Kwantowej metody eksperymentalne, laserowo indukowanej fluorescencji oraz podwójnego rezonansu optyczno-mikrofalowego na strumieniu atomowym.
EN
The work is concerned with the question of precision of spectroscopic measurements necessary for improvement of semi-empirical methods of description of electronic structure of complex atoms. The experimental methods used in Chair of Quantum Engineering and Metrology have been described: laser induced fluorescence and optical-rf double resonance on an atomic beam. The hitherto obtained results have been presented and the perspective of improving their precision have been discussed.
5
Content available remote Fluorymetryczne układy diagnostyczne wczesnej próchnicy zębów
PL
Przedstawiono możliwości wykorzystania metody fluorescencji w diagnostyce wczesnych faz próchnicy zębów. Zbadano wpływ długości fali promieniowania laserowego na charakterystyki emisyjne szkliwa prawidłowego oraz próchnicowego, wykorzystując różne warianty światłowodowych analizatorów widma i układy obrazowania fluorescencji. Poziom autofluorescencji w zakresie 500-600 nm (wzbudzenie 400, 442, 532 nm) szkliwa zmienionego w warunkach in vivo i in vitro jest wyraźnie niższy w porównaniu do normalnego, co uwarunkowane jest zmniejszeniem ilości minerałów i wpływem zmiany uszkodzonej poowierzchni zęba. W zakresie czerwieni obserwuje się niewielki wzrost natężenia fluorescencji szkliwa zmienionego w warunkch in vivo, co związane jest z powstawaniem nowych organicznych fluoroforów, a zmiany te są widoczne również przy wzbudzeniu promieniowaniem czerwonym (633, 650 nm).
EN
The possibilities of application of laser induced fluorescence in diagnostics of early phases of teeth moulder are presented. The influence of the wavelength of laser radiation on emissive characteristics of the correct and mouldered glaze by using different variants of optical fiber analyzators of the spectrum and systems of fluorescence displaying was studied. The autofluorescence level in the interval of 500-600 nm (excitation of 400, 442, 532 nm) of the glaze changed in in vivo and in vitro conditions was found to be remarkably lower than the normal one, which is results by lowering of mineral quantity and the influence of defected tooth surface. In the red region the small increase of the fluorescence intensity of the glaze changed in vivo conditions is observed, which is connected with the occurrence of the new organic fluorofosfors and the changes can be also seen at the excitation by radiation (633, 650 nm).
6
Content available remote Fluorymetryczne układy pomiarowe do diagnostyki nowotworów
PL
W pracy przedstawiono wyniki badań fluorescencji tkanek biologicznych przeprowadzone w układach pomiarowych, w których w torze wzbudzenia zastosowano (e-Cd 9442 nm), SHG-Nd:YAG (532 nm) i He-Ne (632,8). Do rejestracji fluorescencji wykorzystano spektrometry światłowodowe i kamerę ze wzmacniaczem obrazu. Zestawione układy umożliwiają oznaczanie poziomu ehzogennych fotosensybilizatorów w organizmie ludzkim. Zastosowanie różnych długości fal wzbudzenia umożliwia pełną analizę materiału biologicznego w różnych rodzajach tkanek. Przeprowadzone wstępne badania kliniczne wykazały przydatność układów fluorymetrycznych do oznaczania również endogennych fluoroforów, których poziom ulega zmianom przy występowaniu szeregu chorób.
EN
Results of biological tissue fluorescence investigation are presented carried out in the measurement systems in which along the excitation line the He-Cd laser (442 nm), SHG-Nd: YAG (532 nm) and He-Ne (632,8 nm) were used. For fluorescence recording the waveguide spectrometers and camera with the image intensificator were used. The setups enable determination of the exogenic photosensitizer level in the human body. The use of different excitation wavelengths enables a complete analysis of biological material in different kinds of tissue. The initial clinical investigation showed also usefulness of fluorometrical systems for determination of endogenic fluorofor, level of which is subjected to variation during many diseases.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.