Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  large-scale
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The ethanol fire hazards will become more frequent due to the new established targets for the consumption of renewable energy sources. With this in mind, this paper aims to widen the current knowledge on CFD modelling of such a fire. As previous works rely heavily on the data of small pool fire diameters (below 1 m), this research deals with ethanol pool fire on a one-meter test tray, using our own experimental data. A mathematical model was developed and solved using a commercial CFD package (ANSYS Fluent). A new hybrid RANS-LES (SBES) model was employed to calculate turbulent stresses. Generally, the simulation results showed a good fit with the experimental results for flame temperatures at different elevations. In particular, a minor discrepancy was only observed for the top thermocouple (1.9 m above the tray). The flame heights computed with the CFD model were on average higher than the experimental one. Good agreement was observed for the radiative fraction and the axial temperature profile on the plume centreline. The latter showed an almost perfect fit between the temperature profiles obtained from CFD simulations and those calculated from the plume law for temperature.
2
Content available remote System do pomiarów geofizycznych w wysadach solnych
PL
Pomiary geofizyczne w otworach wiertniczych niosą szereg wyzwań pod kątem konstrukcji przyrządów pomiarowych, ich kontroli oraz akwizycji danych. W artykule przedstawiono proces konstrukcyjno – badawczy, związany z powstaniem systemu do pomiarów geofizycznych w wysadach solnych. Zbudowany system pomiarowy składa się z: sondy gamma do pomiaru naturalnej promieniotwórczości, inklinometru do pomiarów usytuowania otworu, kawernomierza wielkośrednicowego do badań kształtu otworu wiertniczego oraz naziemnego układu kontroli i akwizycji danych.
EN
Geophysical measurements in boreholes carry a number of challenges in terms of the construction of gauges, their control and data acquisition. The article presents a construction-research process related to the creation of a system for well-logging in salt deposits. The built-in measurement system consists of: a gamma probe for measuring natural radioactivity, an inclinometer to measure the location of the borehole, a large-scale caliper log for testing the shape of a borehole and a ground-based control and data acquisition system.
EN
In the current paper one has presented an analysis of temperature distribution in a combustor chamber of a 670 MWt circulating fluidized bed boiler (CFB). Initially one has determined a mathematical relation showing an efficiency coefficient of heat transfer from two-phases (i.e. gas-and-particles) mixture to walls of a combustion chamber of CFB operating on a industrial scale. It has been then found that a key parameter influencing the temperature distribution along a height of the combustion chamber is a solids circulation rate of the particles. The higher the parameter is, the more intensive heat transfer from a dense region to a diluted region of circulating fluidized bed structure takes place, and as a consequence an equalization of a vertical temperature profile and a reduction of SO2 and NOx emissions occurring during the combustion process are observed.
PL
W pracy dokonano analizy rozkładu temperatury w strukturze cyrkulacyjnej warstwy fluidalnej kotła o mocy 670 MW. Przedstawiono zależność matematyczną określającą efektywny współczynnik przejmowania ciepła od mieszaniny dwufazowej, tj. gaz-ziarna, do ścian komory paleniskowej kotłów fluidalnych pracujących w skali przemysłowej. Stwierdzono, iż kluczowym parametrem oddziaływującym na rozkład temperatury wzdłuż wysokości komory spalania jest krotność cyrkulacji ziaren materiału warstwy. Wzrost wartości tego parametru sprzyjał intensyfikacji wymiany ciepła z obszaru gęstego do obszaru rozrzedzonego struktury CWF, co w konsekwencji prowadziło do wyrównania pionowego profilu temperatury i ograniczeniu emisji SO2 i NOx powstających z procesu spalania.
EN
The article discuss usage of Berkeley DB data structures such as hash tables and b-trees for implementation of a high performance URL database. The article presents a formal model for a data structures oriented URL database, which can be used as an alternative for a relational oriented URL database.
PL
W artykule omówiono zastosowanie struktur danych z pakietu Berkeley DB, takich jak: tablice z haszowaniem i b-drzewa do implementacji wysoko wydajnych baz danych adresów URL. Przedstawiono model formalny bazy danych zorientowanej na struktury pamieci, która może być alternatywa dla relacyjnie zorientowanej bazy danych linków URL.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.