Three different carbon paste (CP), silk-screen (SP) and poly (vinyl chloride) (PVC) modified electrodes were obtained to verify the reliability of AVELOX, the generic name of which is Moxifloxacin HCl (AV-MOXH). The sensing membranes were containing AVELOX ion associated complexes with sodium tetraphenylborate (NaTPB), phosphomolybdic acid (PMA), phosphotungstic acid (PTA), and ammonium reineckate (RN) as electroactive materials. All three electrodes gave fast, viable, and near-Nernstian linear responses over a relative wide concentration range that ranged from 1.010-6 to 1.010-2 mol/L AV-MOXH at 25°C with a monovalent cationic decrease. The sensors demonstrated a good discernment of AV-MOXH from numerous inorganic and organic compounds such as glucose, sucrose, Na+, Ca+, etc. Additionally, the isothermal coefficients along with selectivity coefficients were calculated. The modified Screen Printed Electrode sensor appeared to be highly sensitive for the determination of AV-MOXH. The electrode response was observed in pH range 2–6 for ISPE electrodes and IPVC electrodes and 3–7 for ICPE electrodes under various temperature conditions. The short response time, lifetime validity, recovery, and all the methods of validation such as limit of detection and limit of quantification were estimated. The potentiometric method turned out to be suitable for determining AV-MOXH in pharmacological formulations, and the findings obtained are comparable to the “HPLC official method” in terms of the agreement. As a result, the postulated potentiometric approach was verified in accordance with IUPAC guidelines.
PL
Otrzymano trzy różne elektrody modyfikowane pastą węglową (CP), sitodrukiem (SP) i polichlorkiem winylu (PVC), w celu oceny skuteczności działania leku AVELOX (nazwa rodzajowa Moxifloxacin HCl, AV-MOXH). Membrany czujników zawierały kompleksy jonu AVELOX z tetrafenyloboranem sodu (NaTPB), kwasem fosfomolibdenowym (PMA), kwasem fosfowolframowym (PTA) i soli Reineckego (RN) jako materiałami elektroaktywnymi. Wszystkie trzy elektrody dały szybkie i bliskie zależności liniowe Nernsta w zakresie stężeń AV-MOXH od 1.0-10-6 do 1.0-10-2 mol/l (w 25°C). Elektrody wykazały dobrą selektywność w oznaczaniu AV-MOXH względem wielu jonów i związków organicznych i nieorganicznych, jak glukoza, sacharoza, Na+, Ca+ itp. Dodatkowo obliczono współczynniki izotermiczne oraz współczynniki selektywności. Zmodyfikowany czujnik z elektrodą sitodrukową okazał się być bardzo czuły do oznaczania AV-MOXH. Badania prowadzono w zakresie pH 2–6 w przypadku elektrod ISPE i IPVC oraz 3–7 w przypadku elektrod ICPE w różnych temperaturach. Oszacowano czas odpowiedzi elektrod, ich czas życia, możliwość regeneracji, odzysk oraz granicę wykrywalności i granicę oznaczalności. Metoda potencjometryczna okazała się być odpowiednia do oznaczania AV-MOXH w preparatach farmakologicznych, a uzyskane wyniki są porównywalne z „oficjalną metodą HPLC”.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Ion selective electrodes for amines and amiloride were prepared using phosphomolybdic acid ionophore and various plasticizers: di-n-butylphthalate (DBPH), tri-n-butylphosphate (TBP), o-nitrophenyloctyl ether (NPOE), and di-octylphenylphosphonatc (DOPP). The response characteristics ofthese electrodes, including slope of the calibration plot, the corresponding concentration range, detection limit, response time, life time, pH effect, and selectivity were studied. The electrode for n-heptylmcthylamine based on DBPH as the plasti-cizer gave the best response; the slope was 58.5 tnV/decade, detection limit was 2.5 x 10-6 mol L-1, and the life time reached 30 days. Also the electrode for amiloride based on DOPPas the plasticizer exhibited excellent sensitivity; the slope of the calibration plot was 58.4 mV/decade, the detection limit was 1.4 x 10-5 mol L-1, and the suitable pH was 3.8. This electrode can be used for determination of amiloride in pharmaceutical tablets.
PL
Spreparowano elektrody jonoselektywne czuie na aminy i amiloryd. Do ich wykonania użyto jako jonoforu kwasu fosfomolibdenowego oraz kilku plastyfikatorów: di-n-buty-loflalan, tri-n-butylofosforan, etero-nitro-fenylooktylowy i di-oktylo-fenylofosfonat. Badano odpowiedzi spreparowanych elektrod, a w tym: nachylenie krzywych kalibrowania, zakres stężeń analitów, granice wykrywalności, czasy odpowiedzi, czasy życia, efekty pH i selek-tywności. Najlepsze wyniki otrzymano z elektrodą czułą na aminęn-hepty lornetyIową zawierającą di-n-butyloftalan jako plastyfikator. W przypadku tej elektrody nachylenie krzywej kalibracji wynosiło 58,5 mV/dekadę, granica wykrywalności-,2,5x10 -6 mol L-1 i czas życia - 30 dni. Elektroda czuła na amiloryd. zawierająca di-oktylo-fenylofosfbnat jako piastfikator, również wykazywała dobrą czuiość: nachylenie wynosifo 58,4 mV/dekade, granica wykrywalności - 1.4 x 10-5 mol L-1, optymalne pH - 3,8. Tę elektrodę można zastosować do oznaczania amilorydu w tabletkach farmaceutycznych.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.