An optical tomograph in which a tested object is illuminated from five directions has been presented in the paper. The measurements of luminous intensity after changing into discrete signals (0 or 1) in the detectors equipped with 64 optical sensors were subjected to reconstruction by means of the matrix algorithm. Detailed description of the measuring sensor, as well as the principles of operation of the electronic system, has been given in the paper. Optical phenomena occurring at the phase boundary while transmitted through the sensor wall and phenomena inside the measuring space have also been taken into account. The method of the sensor calibration has been analysed and a way of technical solution of the problem under consideration has been discussed. The elaborated method has been tested using objects of the known shape and dimensions. It was found that reconstruction of the shapes of moving bubbles and determination of their main parameters is also possible with a reasonable accuracy.
Wyznaczono prędkości lokalne, rozmiary i kształt baniek w zależności od odległości od kapilary, (na której wytwarzano pojedyncze bańki) oraz stężenia roztworów heksanolu-1 i nonanolu-1. Pomiary wykonano w kolumnie szklanej o przekroju kwadratowym stosując oświetlenie stroboskopowe (częstotliwość błysków lampy 100-200 Hz). Stwierdzono, że prędkości lokalne baniek początkowo rosną z odległością od kapilary, a następnie osiągają stałą prędkość tzw. prędkość graniczną. Prędkości graniczne, stopień deformacji i rozmiar bańki maleją ze wzrostem stężenia roztworu. Stwierdzono, że w zakresie wysokich stężeń alkoholi uzyskane wyniki doświadczalne wykazują dobrą zgodność z prędkościami granicznymi baniek obliczonymi z modeli teoretycznych opisujących nich baniek przy dużych liczbach Reynolds'a, w roztworach substancji powierzchniowo aktywnej.
EN
Local velocities, size and shape of the bubbles departing from the capillary orifice were measured as a function of the distance for different concentrations of hexanol-1 and nooanol-1 solutions. Experiments were performed in a square (40x40 mm) glass tube using a stroboscopic illumination (100-200 Hz). It was found that the local velocities initially were increasing with distance from the capillary and then next reached a terminal value. Terminal velocity, deformation and bubble size were decreasing with increasing concentration of the alcohol. It was found that at high alcohol concentrations the experimentally determined terminal velocity values are in a good agreement with that ones calculated from the theoretical models describing motion of the bubbles at high Reynolds numbers in solutions of surface active substances.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.