EN
In order to reduce ventilation heat loss and improve energy efficiency of low-energy buildings air-handling units (AHUs) with heat recovery are used. The article presents results of surveys performed in a passive building located in Katowice concerning the temperature efficiency of heat and cold recovery of two selected AHUs, with different heat exchangers. For this purpose the measurement data from the Building Management System (BMS) for the period 1.08.2015-31.07.2016 were used. The first unit was equipped with a rotary heat exchanger. Its average annual temperature efficiency of heat recovery was 47.2% annually. The efficiency of cold recovery amounted 52.9% on average for the warm half year. The second unit had a cross-flow exchanger. The average annual temperature efficiency of heat recovery in this device was 80.1%. The efficiency of cold recovery amounted 57.2% on average for the warm half year. Additional remarks concerning the temperature measurement in analysed units were also given.
PL
W artykule dokonano charakterystyki dwóch układów wentylacji z zastosowaniem krzyżowych wymienników ciepła. Omówiono budowę central wentylacyjnych wyposażonych w pojedynczy i podwójny wymiennik krzyżowy. Szczegółowo przedstawiono budowę i zasadę działania sekcji odzyskiwania ciepła. Przeanalizowano indywidualną i wspólną pracę rekuperatorów. W tym celu wykorzystano oryginalny model matematyczny wymiany ciepła i masy. Następnie opracowano program komputerowy do przeprowadzania symulacji pracy urządzeń z wykorzystaniem języka programowania Pascal. Przedstawiono wyniki symulacji systemów z jednostopniowym oraz dwustopniowym odzyskiwaniem ciepła. Obliczenia numeryczne przeprowadzono w warunkach ujemnych wartości temperatury powietrza zewnętrznego. Wyznaczono strefy aktywnej wymiany ciepła i masy wewnątrz rekuperatorów. Ujawniono powstawanie trzech stref aktywnej wymiany ciepła i masy w kanałach powietrza wywiewanego krzyżowych wymienników ciepła. Przedstawiono graficznie przykłady bezpiecznej i niebezpiecznej pracy rekuperatorów. Otrzymane wyniki potwierdzają możliwość zwiększenia odzyskiwania ciepła z powietrza wywiewanego. Oprócz tego wykazano, że dwustopniowy układ odzysku ciepła jest bardziej narażony na powstawanie szronu. Dalsze wyniki optymalizacyjne posłużą do prac zmierzających do przeprowadzenia oceny możliwości racjonalnego wykorzystania wymienników krzyżowych, w zależności od konkretnych warunków klimatycznych.
EN
In this paper two ventilation systems using cross-flow plate heat exchangers were described. The construction of air handling units with single and double cross-flow plate heat exchanger has been discussed. The build and principle of operation of heat recovery section were described in detailed manner. Individual and group operation of recuperators have been analyzed. The original mathematical model of heat and mass transfer was used for this purpose. Then, the computer program for simulation of the device operation was written in the Pascal programming language. The results of single and two-stage heat recovery systems were presented. Numerical calculations were carried out under subzero outdoor airflow temperature conditions. The heat and mass transfer areas inside the recuperators were determined. Three heat and mass transfer zones in the return air channels of cross-flow plate heat exchangers were revealed. The examples of safe and unsafe operation were presented graphically. The received results confirm the possibility of increasing heat recovery from return airflow. Moreover, it has been shown that a two-stage heat recovery system is more susceptible to frost formation. The further optimization results will be used for evaluation the possibility of rational use of cross-flow plate heat exchanger, depending on the specific climate conditions.
PL
W artykule przedstawione zostały wyniki symulacji numerycznej procesów wymiany ciepła i masy w ożebrowanym wymienniku wykorzystującym przepływ krzyżowy. Zaprezentowane wyniki dotyczą porównania efektywności temperaturowej dwóch typów wymienników o różnej konstrukcji, analizy wymiany ciepła na powierzchni ożebrowanej oraz wpływu różnych cech charakterystycznych wypełnienia na skuteczność chłodniczą pośrednich rekuperatorów wyparnych.
EN
The first article (RI 3/2014) presented the characteristics of indirect evaporative heat exchangers structure. The materials most often used in for of this type of units construction were presented. Also, the materials that can be used in the future have been shown. Differ-ent types of ribs, used in such devices, were presented, with the original mathematical model ĺ-NTU, describing nonlinear processes of heat and mass transfer in finned heat exchanger that uses the cross- flow pattern has been shown. In this part of the paper the results of numerical simulation will be presented. The results presented refer to comparing the temperature effectiveness of two types of ex-changer with different construction, heat transfer analysis for finned surface and the impact of different filling characteristics on the performance of indirect evaporative cooling recuperators.