Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  korozja ziemna
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A determination of soil corrosivity on three sections of a main gas pipeline in the Western region of Ukraine has been carried out. We have distinguished areas of development of biocorrosive processes with the participation of sulphate-reducing bacteria (SRB). Soil evaluation by the degree of corrosivity has been conducted. We used weight, titrimetric, gravimetric methods, pH-metry, ten-fold limit dilution method and Postgate nutrient medium B for culturing SRB. It has been established that the soil in the first area selected along the lower generatrix of the main gas pipeline has a high degree of corrosivity. It was ascertained that corrosive metal damage increases in the “ferrozone” with the growth of metal exposition time from 24 to 72 hours. The soil selected in the middle part and from above the pipeline refers to soils with a normal degree of corrosive activity. Innovative biostable insulating coatings based on bituminous-polymerous mastic MBPID-1 have been developed, modified with organic inhibitors from the class of quaternary ammonium salts and amines. Regularities of influence of nature of nitrogen-containing corrosion inhibitors of industrial production M, N, L, H and K on the corrosion rate of 17G1S steel for 180 days have been established. It was found that the corrosion rate of steel specimens remained unchanged throughout the study in variants with the presence of inhibitors H and K in the test systems, which indicated their bioresistance to the effect of SRB bacteria.
PL
Zaprezentowano wybrane wyniki długoterminowych pomiarów szybkości korozji stali w ziemi w pobliżu zakopcowanych zbiorników chronionych katodowo. Pomiary dokonywano metodą korozymetrii rezystancyjnej za pomocą czujników o powierzchni eksponowanej 10 cm2 posadowionych w gruncie piaszczystym. Mierzono narastające ubytki korozyjne w okresie 3 lat przed zastosowaniem ochrony katodowej zbiorników oraz ok. 4 lat po jej załączeniu zarówno dla stali polaryzowanej katodowo jak i swobodnie korodującej. Zaobserwowano w niektórych przypadkach wyraźne oddziaływanie ochrony katodowej zbiorników na próbki stali swobodnie korodującej skutkujące obniżeniem ich szybkości korozji.
EN
The paper presents selected results of long-term measurements of the corrosion rate of steel in the ground near the mounded tanks with cathodic protection. Measurements were made using electrical resistance probes with an area of 10 cm2 exposed in sandy soil. Increasing corrosion losses were measured during the three years prior to the application of cathodic protection of tanks and approx. 4 years after it for both cathodically polarized and freely corroding steel. It has been observed in some cases, a marked influence of cathodic protection of tanks on freely corroding steel samples resulting in reduction in their corrosion rate.
3
Content available remote Evaluation of backfill corrosivity around steel road culverts
PL
Przepusty z blach falistych w związku z położeniem w środowisku gruntowym są narażone na możliwość wystąpienia korozji ziemnej. W pracy scharakte­ ryzowano najważniejszy czynnik wpływający na powstanie korozji ziemnej, tj. rezystywność. Przedstawiono także badania rezystywności gruntu w oparciu o geofizyczne pomiary elektrooporowe metodą Wennera. Metoda ta pozwala na pomiar rezystywności gruntu na różnych głębokościach. Przepro­ wadzone badania doświadczalne dotyczyły sześciu przepustów położonych na drogach o różnej klasie (krajowych, wojewódzkich i lokalnych'. Wszystkie badania przeprowadzono w dwóch okresach, tj. latem i wiosną. Minimalna rezystywność gruntu wokół przepustów wynosiła 30 Qm i została ustalona przyjezdni. Uzyskane wyniki wskazują na niebezpieczeństwo wystąpienia korozji ziemnej w przepustach z blach falistych, zwłaszcza położonych na drogach krajowych i wojewódzkich.
EN
Corrugated steel plate culverts in connection with the location in the soil environment are exposed to risk of the soil corrosion. The paper characterizes the most important factor affecting formation of corrosion in the soil, i.e. resistivity. Tests of soil resistivity based on the geophysics electrical resistivity measurements (Wenner method' are presented. This method allows the soil resistivity measurement at various depths. The conducted experimental tests concerned the six culverts situated on different types of roads (national, provincial and local'. All tests were conducted in two periods, i.e. summer and spring. The minimum resistivity of the soil in the vicinity of the steel culverts amounted to 30 Q m and it was established near roadway. The obtained results indicate the peril of the soil corrosion occurrence in the corrugated steel plate culverts, especially located on the national and provincial roads.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.