Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  konwersja energii słonecznej
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The main goal of the study was to investigate the relationship between the orientation of the PVT (PhotoVoltaic Thermal) collector and the thermal and electric power generated. Extensive research was performed to find optimal tilt angles for hybrid solar thermal collectors, which combine photovoltaic as well as thermal collection in a single unit, known as PVT (PhotoVoltaic Thermal) modules for an office building with working hours between 7.00 and 16.00. The comprehensive study included field measurements of the modules in central Poland and tests under AM (air mass) 1.5 conditions in a certified laboratory KEZO (Centre for Energy Conversion and Renewable Resources) Polish Academy of Sciences in Jablonna. Furthermore, a PVT system was investigated using the simulation method based on the dedicated Polysun software. The PV characteristics and efficiency of the PV module and the relation between power or efficiency of the PVT module and incidence angle of solar-irradiance were studied. Optimal work conditions for commercial PVT modules were ascertained. In addition, it was found that the maximum efficiencies of PV module (ηPV), solar thermal-collector (ηc) and PVT hybrid collector (ηPVT) registered under field conditions were higher than the ones measured under laboratory conditions.
PL
W artykule przedstawiono wyniki dziewięcioletnich badań z różnych okresów pracy instalacji fotowoltaicznej. Analizie porównawczej poddano układ nadążny i stacjonarny zainstalowany na budynku Wydziału Elektrotechniki, Elektroniki, Informatyki i Automatyki Politechniki Łódzkiej. System wyposażony jest w połączone szeregowo moduły, które przekazują energię elektryczną do sieci wewnętrznej uczelni. Parametry instalacji są na bieżąco rejestrowane i archiwizowane.
EN
The following paper presents the results of 9 years-time electrical parameters measurements of photovoltaic system working at different periods. They were installed on the building of the Faculty of Electrical, Electronic, Computer and Control Engineering at the Technical University of Łodź. The system is equipped with PV modules connected in series, which transfer electrical energy to the internal university network through converters. system parameters are stored and monitored.
3
Content available remote Zyski energii z ogniw fotowoltaicznych
PL
Samo pozyskiwanie i przetwarzanie energii z odnawialnych źródeł energii w konwencjonalną, elektryczną czy cieplną nie zanieczyszcza środowiska. To wiemy. Pozostają jednak pytania. Jak zagospodarować urządzenia (unieszkodliwić), które zostały wyeksploatowane w procesie przetwarzania tej energii? Ile energii pierwotnej trzeba włożyć, aby takie urządzenie wytworzyć, a następnie zutylizować, bądź o ile to możliwe zregenerować? Czy poniesione koszty związane z produkcją urządzeń do pozyskiwania energii oraz samo jej pozyskiwanie ze źródeł odnawialnych są porównywalne z kosztami pozyskania takiej samej ilości energii ze źródeł konwencjonalnych. Na takie pytania ekonomiczne, jak i wątpliwości technologiczne oraz ekologiczne starano się odpowiedzieć, wykorzystując przykłady urządzeń przetwarzających energię słoneczną w energię elektryczną.
EN
Obtaining energy from renewabIe sources of energy and its conversion into conventional electric or thermal energy does not pollute the environment itself. This is known. However, there are still questions. What way the devices, which were exploited during energy conversion process, should be used (rendered harmless)? How much of primary energy should be put in to create or regenerate (if it is possible) this device? Do the incurred costs connected with production of devices for energy obtaining and itself obtaining from renewabie sources, are comparable with the costs of obtaining the same amount of energy from conventional sources? This kind of economic questions, as well as technological and ecological doubts one tried to answer, using the examples of devices converting solar energy into the electric energy.
4
PL
W pracy przedstawiono wyniki dwuletniej analizy funkcjonowania systemu solarnego Instytutu Fizyki Politechniki Lubelskiej. System ten wykorzystuje równocześnie dwa rodzaje konwersji - fototermiczną i fotowoltaiczną. Do analizy wykorzystano autorski system monitoringu.
EN
This work presents two years analysis of functioning of solar system in Institute of Physics of Lublin University of Technology. This system uses two types of solar energy conversion - phototermal and photovoltaic. The original system of monitoring was used.
5
Content available remote Cienkowarstwowe struktury fotowoltaiczne
PL
Praca poświęcona jest analizie wytwarzania i wykorzystania cienkowarstwowych struktur współczesnych baterii słonecznych. Zjawisko konwersji energii słonecznej odbywa się zazwyczaj w niewielkiej przypowierzchniowej części. półprzewodnikowych struktur krystalicznych. Zatem dla celów użytecznych wykorzystywana jest zaledwie niewielka część materiału, natomiast znaczna jego część stanowi jedynie podstawę konstrukcyjną ogniwa słonecznego.
EN
This work presents the analysis of thin layer technology of modern solar celIs. The photovoltaic conversion is realized in thin region of crystalIine substrates, near the surface. For practical purposes one uses only smalI amount of semiconductor material, but majority of these materials support mechanically PV celIs structures.
6
Content available remote Metodyka badania konwersji energii promieniowania słonecznego w ciepło
PL
Artykuł przedstawia metodykę badania konwersji energii promieniowania słonecznego w ciepło na przykładzie instalacji kolektorów słonecznych w Powiatowym Centrum Kształcenia Praktycznego w Bielawie. System opomiarowania i monitoringu instalacji badawczej umożliwia rejestrowanie i archiwizowanie danych pomiarowych z dowolnie zdefiniowanym krokiem czasowym. Rejestrowane są wartości natężenia całkowitego promieniowania słonecznego, temperatury czynnika grzewczego oraz wartości jego przepływu objętościowego. Po uwzględnieniu zmian gęstości i ciepła, właściwego czynnika grzewczego wynikających ze zmian temperatury, można wyznaczyć wartości chwilowych sprawności instalacji. Rejestracja wartości prędkości wiatru i temperatury powietrza atmosferycznego pozwala określić wpływ tych czynników na sprawność instalacji cieczowych kolektorów słonecznych. Zastosowanie opisanej metody umożliwia określenie ilości ciepła, jaką faktycznie można uzyskać w procesie fototermicznej konwersji energii promieniowania słonecznego w klimatycznych warunkach Polski.
EN
The paper presents a method of research of solar energy conversion into heat on the example of solar collectors ¡n Practical Education Center in Bielawa. Measurement and monitoring system makes possible the registration and storage of the measurement data with any time interval. Global solar radiation, heat- transfer fluid temperature and its flow are registered. Taking into consideration changes of fluid density and its specific heal due to temperature changes - it is possible to calculate the instantaneous efficiency of the installation. Registration of wind velocity and atmospheric air temperatures enables to estimate the influence of these parameters on the efficiency of the fluid solar collectors installation, The method described contributes to precise estimation of the real amount of heat energy which can be obtained in the process of fotothermal conversion in climatic conditions of Poland.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.