Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  konstrukcja pasywna
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Algeria is a country that has witnessed rapid development as a result of its abundant oil supplies. The country’s GDP to energy consumption ratio clearly shows the need to adopt energy efficiency policies. Taking into account the regulation of excess solar radiation in the desert environment, this study examines the relationship between the shape of different buildings and their energy use. This research was divided into two stages. In the first stage, the ideal building shape for the city of Adrar, in terms of energy consumption, was determined by studying three basic geometric shapes, including square, rectangular, and triangle shapes. According to simulation research conducted using Design Builder (version 6.1.0), a square building was the best shape to maximize energy performance. To analyze the thermal behavior of different building shapes, all structures with expanded shapes were simulated based on the ideal shape discovered in the first stage. Of the three extended alternative cases, the case of the Mini Arrival offers the best energy efficiency and sufficient natural lighting thanks to its 90 cm depth and no vertical offset from the top of the window. By adding design principles to the design process, this study helps improve the energy efficiency of new buildings and also gives another angle on research methods for solving energy performance issues regarding desert buildings.
EN
The aim of this paper is to present the requirements for the passive standard based on the example of the RES TTC building. The requirements were divided into main energy demand and detailed recommendations for each indicator. The calculations and analyses have shown that to achieve the required energy demand, better solutions than the recommended ones need to be applied, such as air handling units with better heat recovery efficiency. The same applies to the U heat penetration coefficient of heat for the outer partitions. The use of ventilation units with a recommended efficiency of 75% does not guarantee achieving a passive standard.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.