Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  konfiguracja podstawowa
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Analysis of the CaTV Splitterring Taps
EN
This article presents CaTV splitterring taps. Basic features of the splitterins taps and the influence of basic factor on crucial parameters were investigated in this article. Additionally, correction circuits for improvement of certain parameters were proposed. The research considered the two-way, three-way and eight-way splitterring taps. Some examples of applications of splitterring taps in passive devices used in CaTV network were presented in this paper.
2
Content available remote Analysis of the CaTV cascade taps
EN
This article presents cascade taps. Basic features of the cascade taps and influence of basic factors (ballast resistance, initial permeability, turns configuration) and transformer on crucial parameters were investigated in this article. Additionally, correction circuits for improvement of certain parameters were proposed. The research considers two-way, three-way and four-way cascade taps. Some examples of cascade taps applications were presented in this paper.
3
Content available remote Badanie i optymalizacja szerokopasmowego transformatora kierunkowego
PL
Opracowanie zawiera analizę teoretyczną, wyniki pomiarów i metody optymalizacji szerokopasmowego transformatora kierunkowego. Przedstawiono cztery możliwe konfiguracje transformatora, oraz zbadano wpływy takich czynników jak: przenikalność początkowa, rezystancja balastowa, pojemności międzyzwojowe i montażowe. Do badań posłużono się transformatorem symetrycznym 1O-decybelowym.
EN
Object of present elaboration is complex analysis of the symmetrical directional transformer (directional coupler). Such transformers universally practical are in devices of cable television (CATV), most often in taps. Executed they are on base of little, line 7 x 3.5 mm ferrite cores of double holes, on which wound are windings of the transformer. Examined transformer can exist in four configurations named here: basic, inverse, basic with zero resistor and inverse with zero resistor. Work contains theoretical analysis and results of measurements and calculations of parameters of the transformer like: insertion losses of main and coupled line, isolation of output and tap and return losses on input, output and tap in function of frequency in range 5-1000 MHz. In work examined influence of initial permeability (in range 100-10000), on parameters of the transformer, and such factors as ballast-resistor, zero-resistor considering of obtainment of optimum parameters and its influence on winding and assembly capability of the transformer and its parameters for high frequencies. Besides one examined possibilities of use of corrective arrangements having in view improvement of parameters of the transformer for low and high frequencies. One introduced also effects of such optimization for possible configuration of the transformer. Taking into account optimization and influences of ballast and zero resistors one examined courses parameters of the transformer for its extreme frequencies of work: 5 and 862 MHz. General analysis of the transformer passed in regard on broadband its use, but results of researches can also be use for more particular arrangements. Work addressed is mostly to constructors and has in view help in projecting of arrangements taps. To researches used 10-dB symmetrical transformer with use of cores of initial permeability 1400 and 2500 produced by Taiwan.
4
Content available remote Badanie i optymalizacja szerokopasmowego transformatora dwukierunkowego
PL
W pracy zamieszczono analizę teoretyczną, wyniki pomiarów i metody optymalizacji szerokopasmowego transformatora dwukierunkowego. Przedstawiono dwie możliwe konfiguracje transformatora, oraz zbadano wpływy takich czynników jak: przenikalność początkowa, rezystancja balastowa, pojemności międzyzwojowe i montażowe. Do badań posłużono się transformatorem symetrycznym 15-decybelowym.
EN
Object of present elaboration is complex analysis of symmetrical two-directional transformer (two-directional coupler). This is a new construction which may be use as a device of cable television (CATV), most often as tap. Executed they are on base of little, line 3x3 mm ferrite cores joined, on which wound are windings of the transformer. Examined transformer can exist in two usable configurations named here: basic and inverse. Work contains theoretical analysis and results of measurements and calculations of parameters of the transformer like: insertion losses of main and coupled line, isolation of output and tap, isolation of taps and return losses on input, output and tap in function of frequency in range 5 - 1000 MHz. In work examined influence of initial permeability (in range 100-10000), on parameters of the transformer, and such factors as ballast-resistor, zero-resistor considering of obtainment of optimum parameters and its influence on winding and assembly capability of the transformer and its parameters for high frequencies. Besides one examined possibilities of use of corrective arrangements having in view improvement of parameters of the transformer for low and high frequencies. One introduced also effects of such optimization for two possible configuration of the transformer. Taking into account optimization and influences of ballast and zero resistors one examined courses parameters of the transformer for its extreme frequencies of work: 5 and 862 MHz. General analysis of the transformer passed in regard on broadband its use, but results of researches can also be use for more particular arrangements. Work addressed is mostly to constructors and has in view help in projecting of arrangements taps. To researches used 15-dB symmetrical transformer with use of cores of initial permeability 1400 and 2500 produced by Taiwan.
5
Content available remote Badanie i optymalizacja szerokopasmowego transformatora czterokierunkowego
PL
W pracy zawarto analizę teoretyczną, wyniki pomiarów i metody optymalizacji szerokopasmowego transformatora czterokierunkowego. Przedstawiono dwie możliwe konfiguracje transformatora, oraz zbadano wpływy takich czynników jak: przenikalność początkowa, rezystancja balastowa, pojemności międzyzwojowe i montażowe. W badaniach posłużono się transformatorem symetrycznym 18-decybelowym.
EN
Object of present elaboration is complex analysis of symmetrical four-directional transformer (four-directional coupler). This is a new construction which may be use as a device of cable television (CATV), most often as tap. Executed they are on base of little, line 3x3 mm ferrite cores joined, on which wound are windings of the transformer. Examined transformer can exist in two usable configurations named here: basic and inverse. Work contains theoretical analysis and results of measurements and calculations of parameters of the transformer like: insertion losses of main and coupled line, isolation of output and tap, isolation of taps and return losses on input, output and tap in function of frequency in range 5 -1000 MHz. In work examined influence of initial permeability (in range 100-10000), on parameters of the transformer, and such factors as ballast-resistor, zero-resistor considering of obtainment of optimum parameters and its influence on winding and assembly capability of the transformer and its parameters for high frequencies. Besides one examined possibilities of use of corrective arrangements having in view improvement of parameters of the transformer for low and high frequencies. One introduced also effects of such optimization for two possible configuration of the transformer. Taking into account optimization and influences of ballast and zero resistors one examined courses parameters of the transformer for its extreme frequencies of work: 5 and 862 MHz. General analysis of the transformer passed in regard on broadband its use, but results of researches can also be use for more particular arrangements. Work addressed is mostly to constructors and has in view help in projecting of arrangements taps. To researches used 18-dB symmetrical transformer with use of cores of initial permeability 1400 and 2500 produced by Taiwan.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.