The paper presents the control system and selected results of experimental tests of the AC/DC power converter consisting of an 18pulse diode rectifier based on coupled reactors and a serial active power filter. Proportional integral controllers with decoupling components are implemented in multiple reference frames for selective line current harmonic suppression. The regulator is provided with a backtracking anti-windup mechanism of sorts in which a signal proportional to the saturated control reference is subtracted from the error signal in each reference frame. The fundamental harmonic filter based on the DFT algorithm with phase correction is used for grid synchronization and current harmonic detection. Three configurations of the 15 kVA converter were tested experimentally and then compared: the 18-pulse diode rectifier with and without an additional grid reactor, and the rectifier integrated with an active power filter. The applied control method of active filter significantly reduces harmonic distortion and unbalance of the grid current, which is particularly advantageous under non-ideal supply voltage and low loads conditions.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono analizę pracy w dziedzinie częstotliwościowej trójfazowego dławika sprzężonego CTR, zastosowanego w układzie dwunastopulsowego i osiemnastopulsowego przekształtnika diodowego. Dzięki zastosowaniu zestawów sieciowych trójfazowych dławików sprzężonych, prezentowane przekształtniki pozwalają, niewielkim kosztem, znacznie zredukować niepożądane wyższe harmoniczne w przebiegu prądu sieciowego. W końcowej części artykułu przedstawiono wyniki badań laboratoryjnych przekształtnika osiemnastopulsowego o mocy 20kVA.
EN
The article presents the frequency domain analysis of the work of three-phase coupled reactor (CTR) applicated in twelve-pulse and eighteen-pulse diode converters. In consideration of using sets of coupled three-phase power network reactors, the presented converters makes it possible, by low costs, to considerably reduce undesired higher harmonics in the power network current. The laboratory tests results of 20kVA eighteen-pulse diode converter are presented at the end of the article.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The article presents the principle of operation and results of laboratory and simulation tests of multi-pulse power network converter systems with direct-current voltage output, mating with shunt active power filter (APF). The discussed systems allow for significant reduction of undesirable higher harmonics in the power network current, including the elimination of harmonics of an order of 23 and 25, especially in the local power network supply conditions. The multi-pulse nature of operation of the system is obtained using set of coupled three-phase power network reactors (CTR).
PL
W artykule przedstawiono zasadę działania oraz wyniki badań laboratoryjnych i symulacyjnych wybranych układów przekształtników wielopulsowych o wyjściu stałonapięciowym, współpracujących z filtrem aktywnym małej mocy (APF). Prezentowane systemy pozwalają znacznie zredukować, szczególnie w przypadku autonomicznej sieci zasilającej, niepożądane wyższe harmoniczne, głównie rzędu 23 i 25, w przebiegu prądu sieciowego. Wielopulsową pracę systemu osiąga się dzięki zastosowaniu zestawów sieciowych trójfazowych dławików sprzężonych (CTR).