Four-wire systems are the most common ones in everyday life. Electrical installations within the home, office, or industrial plant are mostly four-wire installations. Receivers connected to such a system are mainly single-phase loads, which from the power connection are an unbalanced three-phase load. Besides, the load imbalance, the supply voltage also has some asymmetry. Voltage asymmetry, load imbalanced, design of reactance compensators are issues that were not simultaneously included in the power equation in fourwire systems. This article presents the mathematical fundamentals of the construction of reactance  compensators operating in voltage asymmetry.
PL
Układy czteroprzewodowe są układami najczęściej spotykanymi w życiu codziennym. Instalacje elektryczne w obrębie domu, biura czy zakładów przemysłowych to w znaczącej większości instalacje czteroprzewodowe. Odbiorniki podłączane do takich obwodów to głównie obciążenia jednofazowe, które z punktu widzenia przyłącza elektroenergetycznego są obciążeniem trójfazowym niezrównoważonym. Oprócz niezrównoważenia obciążenia, napięcie zasilające również posiada pewną niesymetrię. Asymetria napięcia, niezrównoważenie odbiornika, projektowanie kompensatorów reaktancyjnych to zagadnienia, które nie zostały uwzględnione jednocześnie w równaniu mocy w układach czteroprzewodowych. Niniejszy artykuł przedstawia podstawy matematyczne konstrukcji kompensatorów reaktancyjnych pracujących w warunkach asymetrii napięcia.
PL
Układy czteroprzewodowe są układami najczęściej spotykanymi w życiu codziennym. Instalacje elektryczne w obrębie domu, biura czy zakładów przemysłowych to w znaczącej większości instalacje czteroprzewodowe. Odbiorniki podłączane do takich obwodów to głównie obciążenia jednofazowe, które z punktu widzenia przyłącza elektroenergetycznego są obciążeniem trójfazowym niezrównoważonym. Oprócz niezrównoważenia obciążenia, napięcie zasilające również posiada pewną niesymetrię. Asymetria napięcia, niezrównoważenie odbiornika, projektowanie kompensatorów reaktancyjnych to zagadnienia, które nie zostały uwzględnione jednocześnie w równaniu mocy w układach czteroprzewodowych. Niniejszy artykuł przedstawia podstawy matematyczne konstrukcji kompensatorów reaktancyjnych pracujących w warunkach asymetrii napięcia.
EN
Four-wire systems are the most common ones in everyday life. Electrical installations within the home, office, or industrial plant are mostly four-wire installations. Receivers connected to such a system are mainly single-phase loads, which from the power connection are an unbalanced three-phase load. Besides, the load imbalance, the supply voltage also has some asymmetry. Voltage asymmetry, load imbalanced, design of reactance compensators are issues that were not simultaneously included in the power equation in fourwire systems. This article presents the mathematical fundamentals of the construction of reactance  compensators operating in voltage asymmetry.
3
Content available remote Critical comments on the Conservative Power Theory (CPT)
EN
Main features of the Conservative Power Theory (CPT) are examined in the paper. It was concluded that the “reactive energy” as defined in CPT cannot be regarded as a physical quantity. It was demonstrated that separation of the void reactive current can lead to wrong conclusions at a reactive compensator design. It was shown that distortion power defined in the CPT has no relation to mutual distortion of the load voltage and current. The meaning of the term “conservative” as used in the CPT, is discussed as well. It is emphasized that the conservative property of the “reactive energy” is only mathematical, but not physical property of that “energy”.
PL
W artykule przeanalizowano główne właściwości Zachowawczej Teorii Mocy (ang. Conservative Power Theory - CPT). Pokazano, że zdefiniowana w CPT „energia reaktancyjna” nie może być uważana za wielkość fizyczną. Pokazano, że wyodrębnienie z prądu odbiornika „prądu bezużytecznego” (ang.: „void current”) może prowadzić do błędnych wniosków odnośnie kompensacji reaktancyjnej, a ponadto, że zdefiniowana w CPT moc odkształcenia nie ma związku ze wzajemnym odkształceniem prądu i napięcia odbiornika. W artykule analizowane jest także znaczenie pojęcia „zachowawcza”, użytego w nazwie CPT. Pokazano, że „energia reaktancyjna” ma właściwość zachowawczą tylko w sensie matematycznym, lecz nie w sensie fizycznym.