This paper proposes a methodology to identify the reactive and harmonic compensation in three-phase power systems. Considering the behavior of power factor, current and voltage harmonic distortion, unbalance factors and reactive power daily variation, the developed tool is able to select two suitable solutions for power factor correction on the installation under analysis. The results gathered from computational simulations, as well as from measuring an industrial facility are presented and discussed. Based on specialist knowledge the developed tool may be very useful for finding the correct compensation solution quickly even manipulating a large amount of data.
PL
Artykuł proponuje metodykę identyfikacji kompensacji mocy biernej I harmonicznych. Biorąc pod uwagę dzienne zmiany współczynnika mocy, odkształcenia prądów i napięć, współczynników niezrównoważenia oraz mocy biernej, przedstawiona metoda jest w stanie wybrać dwa odpowiednie rozwiązania dla poprawy współczynnika mocy w analizowanym systemie. W artykule przedstawione są i przedyskutowane wyniki zebrane z modelowania komputerowego oraz z pomiarów na obiektach przemysłowych. W oparciu o specjalistyczną wiedzę, przedstawiona metoda może być bardzo użyteczna w szybkim poszukiwaniu poprawnej kompensacji, nawet w przypadku dużej ilości danych.
EN
In this paper, a three-level inverter based Shunt Active Power Filter (SAPF) using Multi-Level Hysteresis Current Controller (MLHCC) is presented for solution of power quality problems in distribution system. A simulation model of SAPF is prepared in Matlab/Simulink environment. MLHCC is used for control of SAPF currents. In simulation study, it is considered that SAPF executes two tasks covering compensation of harmonics and reactive power. Therefore, control algorithm is formed to execute two tasks. The Synchronous Reference Frame Method (SRFM) is used to extract the reference currents. Dynamic performance of SAPF is evaluated using two nonlinear loads switched at different times. Some simulation results are given to show performance of a three-level inverter based SAPF using MLHCC. Simulation results show that current harmonics has been kept inside specific recommendation of IEEE-519 and ac grid is approximately kept in unity power factor.
PL
W artykule przedstawiono bocznikowy aktywny filtr mocy (ang. Shunt Active Power Filter) z trójpoziomowym falownikiem. Sterowanie oparte zostało na wielopoziomowym regulatorze histerezowym prądu (ang. Multi-Level Hysteresis Current Controller). Filtr aktywny spełnia rolę kompensatora wyższych harmonicznych oraz mocy biernej.
EN
Effects of mechanical switched capacitors to the harmonic distortion level were studied in this paper. Moreover, this paper proposes an optimal design method to satisfy the requirements of Harmonic suppressing and reactive power compensation while designing Hybrid Active Power Filter (HAPF). The researches focused on an industrial case involving harmonic distortion and low power factor problems. An effective strategy was developed to observe behaviour of compensation capacitors and passive filters placement with Active Power Filter (APF). A practical implementation was developed for the purpose of problem identifications of filter planning. Then the simulation results are presented to show the effectiveness for the conventional reactive power compensation system with an APF in a distribution system. As a result, the total harmonic distortion and reactive power measurements are analyzed and tabulated.
PL
W niniejszej pracy badano wpływ baterii kondensatorów załączanych mechanicznie na poziom zniekształceń harmonicznych. Ponadto, artykuł ten proponuje optymalną metodę projektowania w celu spełnienia wymogów tłumienia harmonicznych i kompensacji mocy biernej przy projektowaniu Active Hybrid Power Filter (HAPF) – aktywnych filtrów hybrydowych mocy. Badania koncentrowały się na zastosowaniach przemysłowych – zniekształceń harmonicznych i problemów niskiego współczynnika mocy. Została opracowana skuteczna strategia w celu obserwacji zachowania kondensatorów kompensujących i umiejscowienia filtrów (APF). Opracowano praktyczną realizację w celu identyfikacji problemu projektowania filtra. Pokazano rezultaty efektywności konwencjonalnego układu kompensacji mocy biernej z APF w systemie dystrybucyjnym. W końcu, przeanalizowano wyniki pomiarów THD i mocy biernej w układach.