EN
The article presents a study on the influence of shock wave on a Hybrid III anthropomorphic test device (ATD HIII) equipped with an explosive ordnance disposal (EOD) suit. The shock wave was generated by the detonation of SEMTEX 1A plastic explosive, formed in the shape of a 250 g, 500 g, and 840 g sphere, at a distance of 0.5 m, 1 m, and 2 m. The use of ATD allowed for determining parameters of damage to the human body as a result of the impact of overpressure wave. The experiments also included a measurement of such parameters as forces and moments on lower extremi-ties, acceleration of head and pelvis, and forces and moments on a neck simulator. Chest Wall Velocity Predictor (CWVP), calculated from the pressure measured on ADT’s chest, was adopted as the most critical parameter. It was revealed that the allowed distance of explosion of a 500 g pure explosive, which does not cause exceeding the allowed parameters, is 1 m.
PL
W artykule przedstawiono badania wpływu oddziaływania fali uderzeniowej na Antropomorficzne Urządzenie Testowe Hybrid III (ATD, HIII) wyposażone w kombinezon saperski EOD. Falę uderzeniową generowano poprzez detonację z odległości 0,5 m, 1 m, 1,5 m i 2 m plastycznego materiału wybuchowego SEMTEX 1A uformowanego w kule o masie 250 g, 500 g i 840 g. Zastosowanie ATD umożliwiło określenie parametrów uszkodzenia ludzkiego ciała w wyniku oddziaływania fali nadciśnienia. W trakcie eksperymentów mierzono takie parametry, jak siły i momenty na kończynach dolnych, przyspieszenia głowy, miednicy oraz siły, i momenty na symulatorze szyi. Za najbardziej krytyczny parametr przyjęto CWVP (Chest Wall Velocity Predictor – wskaźnik prędkości ugięcia ściany klatki piersiowej) wyliczany z ciśnienia zmierzonego na klatce piersiowej ATD. Wykazano, że dopuszczalna odległość eksplozji czystego ładunku wybuchowego o masie 500 g, który nie powoduje przekroczenia dopuszczalnych parametrów, to 1 m.
EN
The increasing threats of a terrorist attack by means of improvised loads make us look for answers to the question what destructive traits they can have for people. A way to find the answer to this question may be to study the impact of shockwave on people dealing with the neutralization of explosive devices. Neutralization and identification of this type of material are carried by specially trained pyrotechnicians, who are dressed in specialized protective bomb suits. The article presents the results of experimental research, which aimed at identifying the impact of shockwave on pyrotechnicians. As a part of the research, carried out in an interdisciplinary team of engineers and pyrotechnicians, 4 attempts of the TNT explosion were made and the acceleration of selected parts of the body as well as temperature were measured. During the research, two high-speed cameras, a thermal imaging camera and acceleration sensors were used as well. The sensors were mounted on the anthropomorphic dummy, thanks to which the levels of these parameters were determined for the head, pelvis and upper limb, generated by detonating 75, 200, 400 and 1000 grams of TNT. The innovative approach was to use a high-speed thermal imaging camera and attempt to determine the impact of the thermal burst of an explosion on a human being.
PL
Narastające zagrożenia zamachem terrorystycznym za pomocą ładunków improwizowanych skłania do poszukiwania odpowiedzi na pytanie, jakie cechy niszczące dla człowieka posiadają tego typu ładunki. Drogą do znalezienia odpowiedzi na to pytanie może być badanie wpływu oddziaływania fali uderzeniowej wybuchu na ludzi zajmujących się neutralizacją ładunków wybuchowych. Neutralizacją oraz identyfikowaniem rodzaju materiału na miejscu zdarzenia zajmują się specjalnie do tego celu wyszkoleni pirotechnicy, którzy ubrani są w specjalistyczne kombinezony ochronne. W artykule przedstawiono wyniki badań eksperymentalnych, których celem była identyfikacja oddziaływania fali uderzeniowej wybuchu na pirotechników. W ramach badań, przeprowadzonych w interdyscyplinarnym zespole inżynierów oraz pirotechników przeprowadzono 4 próby eksplozji trotylu i dokonano pomiaru przyspieszenia wybranych części ciała oraz temperatury. W trakcie badań zastosowano dwie szybkie kamery, kamerę termowizyjną oraz czujniki przyspieszenia. Czujniki zamocowano na antropomorficznym manekinie, dzięki czemu określono poziomy tych parametrów w przypadku głowy, miednicy oraz kończyny górnej, wygenerowanych przez zdetonowanie 75, 200, 400 oraz 1000 gram trotylu. Nowatorskim podejściem było zastosowanie szybkiej kamery termowizyjnej i podjęcie próby określenia wpływu obciążenia termicznego wybuchu na człowieka.