Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  koagulacja-flokulacja
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The purpose of the presented research is to analyse possible methods of thickening of the Microcystis aeruginosa (Kützing) Kützing cyanobacteria using the obtained concentrate as a biomass for the production of energy carriers and biologically valuable substances. Method of cyanobacteria thickening under the action of electric current and in the electric field, as well as the method of coagulation–flocculation and gravity thickening, was experimentally investigated in labscale conditions. Electrical methods didn't show positive results for the Microcystis aeruginosa thickening, despite the reports of their potential efficiency in a number of previous studies. The high efficiency of the method of coagulation– flocculation and gravity thickening of Microcystis aeruginosa suspensions was obtained. The optimum concentrations of industrial polymeric coagulants and flocculants for the thickening of Microcystis aeruginosa suspensions were defined in the range of about 10 ppm for the coagulants and about 1 ppm for the flocculants. Negative effect of the previous cavitational treatment of the diluted suspensions of Microcystis aeruginosa on the effectiveness of the coagulation–flocculation and gravitational thickening was confirmed experimentally. Hydrodynamic cavitation should be recommended to use after the thickening as the next step of processing of concentrated suspensions of Microcystis aeruginosa to achieve maximum extraction of energy carriers and biologically valuable substances.
PL
Celem przedstawionych badań była analiza możliwych metod zagęszczania cyjanobakterii Microcystis aeruginosa (Kützing) Kützing do uzyskania koncentratu biomasy przydatnego do produkcji energii i substancji czynnych biologicznie. W skali laboratoryjnej analizowano metody zagęszczania pod wpływem prądu i pola elektrycznego oraz metody koagulacji– flokulacji i zagęszczania grawitacyjnego. Metody elektryczne nie dały pozytywnych wyników mimo wielu wcześniejszych badań na temat ich potencjalnej efektywności. Dużą efektywność uzyskano natomiast w przypadku metod koagulacji– flokulacji i grawitacyjnego zagęszczania zawiesiny Microcystis aeruginosa. Optymalne stężenie przemysłowych polimerowych koagulantów użytych do zagęszczania ustalono na 10 ppm, a flokulantów – na 1 ppm. Doświadczalnie potwierdzono ujemny wpływ wcześniejszego poddawania rozcieńczonych roztworów Microcystis aeruginosa działaniu kawitacji na skuteczność zagęszczania metodami koagulacji i flokulacji oraz zagęszczania grawitacyjnego. Hydrodynamiczną kawitację zaleca się stosować po zagęszczaniu, jako następny etap w przetwarzaniu zagęszczonej zawiesiny Microcystis aeruginosa do postaci nośnika energii i pozyskania substancji biologicznie czynnych.
PL
Celem badań było określenie skuteczności podczyszczania odcieków składowiskowych z wykorzystaniem koagulacji, ozonowania i reakcji Fentona.
EN
The objective of the research was to study coagulation-flocculation, ozonation and Fenton’s process pretreatment on a stabilized landfill leachate. The leachate came from a municipal sanitary landfill, located near Bielsk Podlaski, (Podlaskie viovodeship). Main parameters were at average: pH 7,69; COD 1125 mgO2/dm3; BOD 143 mgO2/dm3; NH4+ 658 mgN/dm3; UV absorbance 0,326 and turbidity 59 NTU. An individual and integrated technique consisted of coagulation, Fenton’s reaction, ozonation and coagulation / ozonation was examined. The coagulation of leachate samples was accomplished by addition of Iron(III) sulfate. Maximum COD, color and UV absorbance removal rates at 44,8%, 75,5% and 67% were achieved by adding of 350 mgFe/dm3 of Iron(III) sulfate as Fe3+ respectively. The ozone dosages were used in the range of 50 to 750 mgO3/dm3 of the leachate. The maximum COD, color and UV absorbance removal was respectively 23,3%; 30,2% and 27,9% by applying a high ozone dose of 750 mgO3/dm3. After oxidation, the ratio of BOD /COD was increased from 0.11 up to 0.16. Fenton process reduced the COD, color and UV absorbance of the leachates by 64,9; 81,1and 68,7% respectively. Best operative conditions were obtained with Iron(III) sulfate dose 150 mgFe/dm3, and maximum hydrogen peroxide dose 2100 mgH2O2/dm3 (reaction time: 2h). Advantages associated with Fenton’s reagent include higher organic removal capacity, and bigger production of biodegradable byproducts, measured as BOD/COD ratio.
PL
Powstające w wyniku składowania odpadów komunalnych odcieki zawierają liczne zanieczyszczenia, wśród których zidentyfikowano łącznie ponad 200 związków organicznych, zawierających głównie jednopierścieniowe i dwupierścieniowe węglowodory aromatyczne, w stężeniach dochodzących nawet do kilkuset µg/dm3. W trakcie składowania odpady podlegają fizykochemicznym i biologicznym przemianom. Zanieczyszczenia powstają głównie w wyniku degradacji części organicznej odpadów, które migrują wraz z wodami opadowymi i roztopowymi, tworząc tak zwane odcieki charakteryzujące się zazwyczaj wysokim stężeniem ChZT, barwy oraz wysoką ogólną zawartością rozpuszczonych soli, głównie chlorków.
EN
The main aim of this work was to examine the application of coagulation and ozonation for the pretreatment of raw leachates. The average characteristics of samples were: pH 8,1, color 5840 gPt/m3, COD 2745 gO2/m3, BOD 250 gO2/m3. The content of substances of total dry residue was 6225 g/m3, electrolytic conductivity 10,6 mS/cm. After coagulation of polyaluminum chloride COD was 1801 gO2/m3, color 2832 gPt/m3, BOD 112 gO2/m3. After ozonation effect removal of COD was 3,3% at the dose of ozone 0,1 gO3/dm3 and 13% (0,7 gO3/ dm3). However, the eff ect of color removal ranged from 6.4% to 24.3%, respectively, at the lowest and highest doses of ozone. The use of ozone after coagulation process allows us to increase the effect of the removal of color and COD at the highest dose of ozone 1 gO3/m3 respectively to 86 and 56%.
EN
The characteristic of organic substances in municipal landfill leachate was presented and the influence of landfill age on organics concentrations was discussed. The occurrence of hazardous compounds like BTEX, polyaromatic hydrocarbons (PAH) and chlorinated compounds were analyzed. Moreover, the most popular physico-chemical methods treatment was reviewed. A particular focus was given to coagulation/flocculation, adsorption, advanced oxidation. processes and membrane processes.
PL
Przedstawiono charakterystykę zanieczyszczeń organicznych występujących w odciekach pochodzących ze składowisk odpadów komunalnych z uwzględnieniem związków uznawanych za niebezpieczne, w tym BTEX, WWA (PAH) i związków chloroorganicznych. Omówiono zależność pomiędzy wiekiem składowiska a rodzajem i stężeniem zanieczyszczeń organicznych występujących w odciekach. Dokonano przeglądu piśmiennictwa dotyczącego oczyszczania odcieków pochodzących ze składowisk ustabilizowanych z zastosowaniem najczęściej wykorzystywanych metod fizykochemicznych, tj. koagulacji/flokulacji, adsorpcji, pogłębionego utleniania oraz metod membranowych.
EN
The coagulation-flocculation of model wastewater was studied to compare the coagulation performance of PAC, Al2(SO4)3 and PIX. The proposed hypothesis that the amount of a coagulant bas to be precisely determined based on the condition of the minimum of the parabola dx = 0 was confirmed for aluminum coagulants. It was found that the dose of PIX should be calculated using the coordinates of the point of intersection of appropriate straight lines. Then the mechanism of phosphorus removal from model wastewater was examined under conditions of the optimum (constant) coagulant dose. The AI:P molar ratio obtained in the study enabled to exclude the possibility of chemical precipitation of any aluminum orthophosphate. The determination coefficient R2 for a converted equation of the Langmuir adsorption isotherm indicated chemical nature of orthophosphate (adsorbate) binding by colloidal micelles of Al{OH}3 and Fe{OH}3 (adsorbent). Finally, the adsorption equilibrium constant and maximum adsorption capacity were suggested for the sorption process under consideration.
PL
Porównano zdolność koagulacyjną PAC-u, Al2(SO4)3 i PIX-u w ściekach modelowych. Dla koagulantów glinowych potwierdzono słuszność nowej koncepcji dokładnego obliczania ilości koagulantu z warunku minimum paraboli dx = 0. Stwierdzono, że dawkę PIX-u należy obliczać ze współrzędnych przecięcia odpowiednich prostych. W warunkach "dawki optymalnej" koagulantu badano mechanizm usuwania fosforu z koagulowanych ścieków modelowych. Wartości współczynnika determinacji R2 dla skonwertowanego równania izotermy adsorpcji Langmuira wskazały na chemiczny charakter wiązania fosforanów(V) przez koloidalne micele {Al(OH)3} i {Fe(OH)3}. W konsekwencji takiej konkluzji określono stałą równowagi i "adsorpcję maksymalną" dla badanego procesu sorpcji. Ustalona molowa zależność AI:P wykluczyła chemiczne wytrącanie osadu jakiegokolwiek fosforanu(V) glinu.
6
Content available remote Colloidal sorbents wastewater coagulation
EN
Coagulation performance of PAC, Al2(SO4)3 and PIX in model wastewater was compared. For aluminium coagulants the proposed hypothesis that the amount of a coagulant has to be precisely determined based on the condition of the minimum of the parabola dx = 0 was confirmed. It was found that the dose of PIX should be calculated using the coordinates of the point of intersection of appropriate straight lines. Then under conditions of an optimum coagulant dose the mechanism of phosphorus removal from model wastewater was examined. The determination coefficient R2 for a converted eąuation of the Langmuir adsorption isotherm indicated chemical naturę of phosphate(V) binding by colloidal micelles of {Al(OH)3} and{FeCOH)3}.
PL
Porównano zdolność koagulacyjną PAC, Al2(SO4)3 i PDC w ściekach modelowych. Dla koagulantów glinowych potwierdzono słuszność nowej koncepcji dokładnego obliczania ilości koagulantu z warunku minimum paraboli dx = 0. Stwierdzono, że dawkę PK należy obliczać ze współrzędnych przecięcia odpowiednich prostych. W warunkach „dawki optymalnej" koagulantu badano mechanizm usuwania fosforu L koagulowanych ścieków modelowych. Wartości współczynnika determinacji R2 dla skonwertowanego równania izotermy adsorpcji Langmuira wskazały na chemiczny charakter wiązania fosforanów(V) przez koloidalne micele {Al(OH)3} i {Fe(OH)3}.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.