Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 7

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  kabel energetyczny
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Power lines or underground power cables generate electromagnetic interaction with other objects near to them. This study evaluates the magnetic field emitted by underground extra high voltage cables. The presented work aims to show a numerical simulation of the magnetic field of a buried 400 kV underground power line, which is used as a novel prototype in several countries at a short distance. The underground power cable study, in the presence of the current harmonics at different positions, with time variation by finite element resolution, using Comsol Multiphysics with Matlab software in two dimensions. The simulation results illustrate the magnetic flux density variation-in terms of amplitude and distribution as a function of different actual harmonics rates. The underground cable performance and magnetic field have affected by the harmonics effects. The maximum magnetic induction levels generated by significant harmonics are superior to the limits recommended by the international standard norms. In this paper, shielding has been used as an appropriate remedy to attenuate the magnetic field.
PL
W artykule przedstawiono parametry techniczne kabli w izolacji i powłoce XLPE/PE vs PVC/PVC ich zalety i wady. Zwrócono uwagę na wpływ samego produktu na proces budowy i jego uproszczenia. Analizując poszczególne etapy życie produktu i ponoszone koszty, zwrócono uwagę na rosnące koszty opex i ponoszonych strat.
EN
The article presents technical parameters of cables in XLPE/PE insulation and sheath vs PVC/PVC their advantages and disadvantages. Attention was paid to the influence of the product itself on the construction process and its simplification. Analyzing the individual stages of product life and costs, attention was paid to increasing opex costs and incurred losses.
PL
W artykule scharakteryzowano podstawowe zagadnienia związane z wyznaczaniem na drodze obliczeniowej obciążalności długotrwałej kabli energetycznych umieszczonych w przepustach. Podano problemy klasycznego obwodowego podejścia do niniejszego zagadnienia, wynikające przede wszystkim z ograniczonych możliwości precyzyjnego odzwierciedlenia warunków roboczych. Podano podstawowe modele polowe oraz wpływ zwyczajowo przyjmowanych uproszczeń na jakość wyników symulacyjnych.
EN
The paper refers to the modelling and simulations problems that occur during designing of cable conduits. The basic requirements in such issues concentrate to the optimal determination of long-term load in cable conduits, as the function of cable diameter. Many of commonly used calculating procedures do not allow for an accurate account of real environmental parameters. In the article some aspects of precisely modelling of high voltage cable lines placed in conduits were described. The influence of commonly used simplifications of mathematical models, on calculating precision was shown.
PL
W artykule opisano sposób działania zespołu zabezpieczeniowo-pomiarowego SEPAM 80 oraz zinterpretowano użyty w nim algorytm służący do wypracowania stosownej chwili wyłączenia prądu zasilającego kabel elektroenergetyczny w celu ochrony przed nadmiernym temperaturowo obciążeniem. Wykazano zasadność użytych wzorów oraz skuteczność stosowanych algorytmów, konfrontując ich wskazania z wynikami badań zarówno symulacyjnych modelu cieplnego kabla XHAKXS2 jak i rzeczywistych, uzyskanymi w laboratorium zwarciowym. Wykazały one ponadto znaczącą wrażliwość działania zabezpieczenia na wprowadzane parametry wejściowe, takie jak np. stała czasowa kabla, które znane są jedynie szacunkowo na podstawie nieprecyzyjnych wytycznych podanych w folderze firmowym Schneider-Electric promującym to urządzenie.
EN
This paper describes the operation of the measuring-protective SEPAM80 unit as well as implemented algorithms used for evaluation of the tripping time protecting cable against overloads. The theoretical conformity and correctness of implemented formulas as well as their efficiency were shown, verified by numerical simulation and thermal laboratory tests. Additionally, they also showed the distinctive sensitivity of the SEPAM80 unit to input parameters, for example, cable time constant, which is not precisely determined and is chosen on the basis of suggestions given in the Schneider-Electric catalogue of the product.
PL
Opisano wyniki badań wpływu temperatury na wytrzymałość złączy aluminium-miedź (Al-Cu) wykonanych technologią obróbki plastycznej na zimno. Odcinki prętów spajano metodą spęczania ich końców. Próbki wyżarzano w temperaturze 300, 400, 530, 540 i 570°C, stosując różny czas wygrzewania i różne sposoby chłodzenia. Badania strukturalne wykazały, że począwszy od temperatury 400°C w złączu powstaje strefa twardych i kruchych związków międzymetalicznych CuAl, CuAl2, CuAl2O4, Cu9Al4, układających się w przylegające do siebie warstwy o łącznej grubości od 30 do 100 žm. Wszystkie złącza zawierające związki międzymetaliczne pękały w próbie gięcia przy sile kilkakrotnie mniejszej od siły potrzebnej do wygięcia danej próbki w stanie niewyżarzonym. Stwierdzono, że wartość siły pękania jest tym mniejsza im wyższa była temperatura nagrzania złącza.
EN
The results of the investigation of the influence of temperature on the strength of aluminium-copper bonds obtained by the technology of cold metal forming have been described. Bar sections have been joined by the method of upsetting their ends. The samples were annealed at 300, 400, 530, 540 and 570°C with various heating times and various ways of cooling. Structural examinations have shown that a zone of hard and brittle intermetallic compounds, CuAl, CuAl2, CuAl2O4, Cu9Al4, forms in the bond, beginning from the temperature of 400°C. The compounds are arranged in layers adhering to each other with the total thickness of 30 to 100 mm. All the bonds containing intermetallic compounds broke in bending test at a force several times lower than the one necessary to bend the given sample in not annealed condition. It has been found that the higher was the temperature of the bond heating, the lower is the value of the breaking force.
PL
Przedstawiono nowe konstrukcje kabli optotelekomunikacyjnych: kabel energetyczny z modułem światłowodowym i kable światłowodowe przeznaczone do instalacji w kanalizacji ściekowej. Omówiono metodykę badań i czynniki wpływające na niezawodność produkowanych kabli, w tym mechanizm kompleksowego zarządzania jakością TQM.
EN
New constructions of optotelecommunication cables - power cable with fiberoptic module and fiberoptic cables for sewage system installation - are presented. Research methodology an factors that influence the reliability of cables, including comprehensive quality management TQM are discussed
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.