Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  joint flexibility
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Based on the numerical simulation performed within the Abaqus computational environment for a typical end-plate beam-to-column joint the influence of the endplate thickness on the effective joint rigidity has been verified. The initial joint rigidity at first determined for 20 mm thick end-plate has been compared with rigidity of the joint constructed with substantially more flexible end-plates 10, 8 and 6 mm thick. In all the considered cases the column was equipped with horizontal ribs stiffening the web at the height of beam top and bottom flange. No diagonal ribs were applied. In addition the column flange at the zone directly adjacent to the beam end-plate in all the analyzed cases has been set to 30 mm. This way it did not affect the computationally determined rigidity of considered joints. Juxtaposition of M-ϕ curves characterizing the considered joints and depicting the relationship between the applied bending moment and relative change of the initial angle between undeformed axes of beam and column in the analyzed frame indicates qualitatively different modes of destruction of the considered joints, and thus different computational models determining their bearing capacity. In the first case obtained parameters seem to indicate that the joint is nominally rigid but in all the remaining cases the bearing capacity seems to be exhausted by the increasing deformation of the more and more flexible end-plate.
2
Content available remote Problemy analizy statycznej drewnianych konstrukcji szkieletowych
PL
Artykuł przedstawia problemy związane z analizą pracy statycznej szkieletowych konstrukcji drewnianych. Zaprezentowano wpływ podatności materiałowej oraz konstrukcyjnej drewna na sposób pracy wybranych elementów konstrukcji, co przekłada się na pracę całego obiektu. Przedstawiono przegląd badań doświadczalnych wykonanych przez autorów. Przeprowadzono testy na elementach konstrukcji szkieletowych w skali naturalnej oraz badania laboratoryjne podatności węzłów i połączeń w tego typu konstrukcjach.
EN
The paper presents problems related to the analysis of static work of light wood-frame structures. The impact of material and structural flexibility on the behaviour of individual structural elements is discussed because of affect on entire building work behaviour. An overview of the experimental studies conducted by the authors is presented. Full-scale testing of wall and floor elements has been carried out, as well as microscale experiments of joint flexibility.
EN
The issue of the free vibrations of the non-prismatic rod subjected to the selected case of the specific load has been studied. In the carried out simulations, a flexibility of a constructional joints modelled by the translational and rotational springs at the point of mounting or on the free end of analysed system was taken into account. The shape of rod was approximated by linear function and by polynomial of degree 2, under the condition of constant volume of the column. After prior definition of total mechanical energy, a differential equations of motion as well as a boundary conditions were formulated on the basis of the Hamilton’s principle. The results of the numerical calculations refer to an influence of variable cross-section of the rod, joint flexibility and a geometry of a loading structure on the value of the frequency of free vibrations due to the external load (a characteristic curves) and on the critical load.
PL
W pracy porównano dwie alternatywne techniki obliczeniowe pozwalające na wiarygodną specyfikację miarodajnych do warunków pożaru rozwiniętego charakterystyk moment – obrót. Charakterystyki tego typu są obiektywną miarą zmieniającej się wraz z rozwojem pożaru podatności stalowego węzła konstrukcji nośnej. Analizę przeprowadzono na przykładzie typowego węzła rygiel – słup. W pierwszym przypadku relacje skojarzone z zadaną temperaturą elementów budowano zgodnie ze znaną a priori charakterystyką odpowiadającą temperaturze pokojowej, w drugim zaś poprzez uogólnienie klasycznej metody składnikowej, aby ewentualne wpływy termiczne zostały uwzględnione w każdym potencjalnym modelu zniszczenia składników węzła. Wykazano, że porównywane metody nie są równoważne. Pierwsza z nich nie uwzględnia bowiem niezależnej redukcji wytrzymałości śrub w temperaturze pożarowej, co staje się szczególnie istotne, gdy temperatura węzła osiąga wartość większą od Θ = 400°C.
EN
Two alternative calculation techniques are compared in detail in the presented article. Both of them deal with the specification of moment – rotation characteristics, related to the fully developed fire conditions. Characteristics of this type are accepted as the objective measure of steel structural joint flexibility, increasing with the fire development. The analysis made on an example is related to the typical beam-to-column joint. The first approach allows to construct the relations being suitable for the assumed joint temperature if only the appropriate characteristic is known in advance, specified for the room temperature conditions; whereas the second one, based on the generalization of the classical component methodology, is connected to the consideration of potential temperature influence on each conclusive failure mode being identified for particular joint members specified previously. As a conclusion it is shown that the compared techniques are not equivalent because the reduction of bolts resistance under fire conditions is neglected if only the first of these algorithms is used in practice. The quantitative difference between obtained results becomes particularly significant when the joint temperature exceeds the value Θ = 400°C.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.