EN
A microbiological analysis of indoor air quality in offices, lecture rooms, and hallways in a public utility building has been carried out in the Lubuskie Voivodship (Poland). In one of the storage rooms, the presence of fungi on the building partition was found in the place of water infiltration as a result of a technological failure in the building. A total of 17 nonresidential interiors were examined. The total number of psychrophilic and mesophilic bacteria and the total number of fungi were sampled by the collision method with the air sampler. A qualitative analysis has been performed of fungi present in the indoor air and from building partition of the studied interiors. A total of 11 species of fungi have been specified. Relative humidity and air temperature were measured with a hygrometer. The studies showed that the number of psychrophilic bacteria in indoor air was in the range 0-730 CFU/m3 , while the number of mesophilic bacteria was slightly higher (0-896 CFU/m3 ). A high level of contamination and a large number of fungi (734 CFU/m3 ) were found in the indoor air of storage room, where the problem of biodeterioration of building partitions occurred. In the remaining rooms, the level of microorganisms was low or moderate. Microbiological tests of the outdoor air (background) did not reveal an excessive number of microorganisms in the air.
PL
Wysokie ryzyko zakażenia się koronawirusem beta SARS-CoV-2 spowodowało, że w wielu krajach rozgorzały dyskusje na temat sposobów walki z rozprzestrzenianiem się patogenów w pomieszczeniach i w tym kontekście - odpowiedniej ich wentylacji. Dzięki debatom prowadzonym publicznie, wzrosła świadomość ludzi, jak ważne jest dla naszego zdrowia czyste powietrze. Wentylacja kontrolowana lub naturalna, obok dezynfekcji, okazały się bardzo skuteczne w minimalizacji zagrożeń.
EN
One of the modern methods of reducing vibrations of plates and beams is using piezoelectric materials in the form of distributed elements or patches (applied in a passive or an active system). However, for the multimodal response of a structure, there is no possibility to place the actuators in exactly the areas with maximum curvature values for each mode. Additionally, in the case of passive multimodal suppression systems – in which energy is needed to be supplied to the system – there is the necessity to create a complicated electrical circuit. The particular electrical shunts of the circuit are tuned to the specific vibration forms which require damping. The main objective of this article is to show the possibility of creating a multimodal vibration suppression system with typical resonant shunts and proposed second slightly modified.
PL
W artykule podsumowano jakość powietrza wewnątrz hali sportowej wybudowanej w standardzie pasywnym. Warunki sanitarne w obiekcie zostały zmierzone i przeanalizowane w celu sprawdzenia, czy normy zostały spełnione i czy badany obiekt był bezpieczny dla użytkowników.
4
Content available Thermal comfort in intelligent buildings
EN
The paper presents the issue of thermal comfort conditions with regard to intelligent buildings. First the principles of thermal comfort are discussed, namely the parameters affecting the human perception of the best indoor air conditions. Among the mentioned parameters indoor temperature seems to be especially vital for humans. In the second part the test results of temperature changes in the Energis building are presented together with the discussion.
EN
The computational fluid dynamics (CFD) analysis of the indoor environment in buildings requires numerical modelling of a human being (computer simulated person – CSP). There are two crucial aspects in developing reliable CSP models: the CSP geometry and the breathing model. This paper focuses on the analysis of different breathing models for application in the CFD modelling. Three breathing models were analysed: first model was restricted to constant exhalation, second model, the so-called full breathing, included constant rate inhalation, constant rate exhalation and pause period, and in the third model temporal variation of flow rate was represented by sinusoidal function. The main findings from this work show that all three models compared with experimental data gave reliable results. The spatial distribution of CO2 concentration and velocity showed only small differences among the models in the vicinity of the mouth and above the person. It was shown that a simplified constant exhalation model can be effectively used for the CFD analysis of the indoor air quality (IAQ). However, a detailed simulation of micro-environment in the room and transport of contaminants should include complete breathing.
PL
W artykule przedstawiono wyniki trzyletnich badań mikrobiologicznego zanieczyszczenia powietrza i parametrów mikroklimatycznych prowadzonych w doświadczalnym budynku pasywnym Politechniki Poznańskiej (DoPas) oraz w środowisku zewnętrznym. Prezentowane wyniki stanowią część większego projektu dotyczącego badań jakości powietrza w budynkach. Badania mikrobiologiczne prowadzono zgodnie z zaleceniami polskich norm.
EN
The article presents the results of three years of microbiological testing of air contamination and micro-climatic conditions in the interior and on the outside of an experimental passive building of the University of Technology in Poznań (DoPas). The results are a part of a larger project concerned with the testing of air quality in buildings. The microbiological tests followed the recommendations of the applicable Polish standards.
PL
W ostatnich latach w Polsce obserwuje się dynamiczny wzrost oczekiwań w odniesieniu do poziomu wyposażenia budynków. Coraz częściej pomieszczenia biurowe, obiekty użyteczności publicznej oraz budynki mieszkalne o podwyższonym standardzie wyposażane są w nowoczesne systemy wentylacji mechanicznej lub klimatyzacji.
PL
Przedstawiono wyniki pomiarów poziomów stężeń aerozolu bakteryjnego i mikro grzybowego, oraz identyfikacji gatunkowej izolowanych grzybów ciepłolubnych, występujących w pokojach biurowych, zlokalizowanych na terenie Miejskiego Zakładu Składowania Odpadów w Sosnowcu. Na podstawie badań własnych oraz danych literaturowych dokonano oceny wpływu wysypiska odpadów komunalnych na mikrobiologiczną jakość powietrza w badanych pokojach.
EN
The results of the bacterial and fungal aerosol concentration measurements and the composition of thermophilic fungal flora occuring in office rooms, located in the area of the municipal waste ladfiil in Sosnowiec, are presented. On the basis of the obtained results and the literature data, the influence of the minucipal waste landfilI on the microbiological air quality in the investigated rooms was assessed.