This research is aimed to test the high voltage (HV) polymeric insulators to study Electrical Performance and deterioration at the insulator’s surface under the wheel test conditions. The samples of this research are four new silicone rubber with fiber-reinforced plastic rod insulators, FXB 22/70 model 22 kV that randomized from the commercial market in Thailand. The experiments in this research are the IEC/TR 62730 standards HV polymeric insulators for indoor used tracking wheel test. The results found that the samples’ resistance before and after the wheel test of 30,000 cycles has the lower resistance of 10 mm distance on the samples of 37.0 and 7.76 G, respectively. The sample resistances were higher than 2 M resistances, less than 3 mm erosion depth, and no punctured on the shed, housing, or interface that the criteria of the IEC/TR 62730 standards are accepted. Further, the hydrophobicity of the samples before and after the treatment were reduced from HC 1 to HC 6 that classified use STRI’s guide. The average leakage currents of the first 10,000 and 30,000 cycle’s wheel test were 0.037 mA and 0.074 mA, respectively. While, after 6,000 cycles of the test, the thermography showed that the areas at the end of insulator near the ground terminal were higher temperature than other, else after 30,000 cycles test, the insulator’s temperatures were higher at the core rod. Furthermore, the 1000x SEM photography shown that the three punched samples of the insulator’s surfaces of the new were smooth. After 15,000 cycles, the skins have aging than more and deeper textures after 30,000 cycles testing. Besides, the Fourier transform infrared spectroscopy found that the ATH of the samples before and after the treatment was reduced from 3,445.4 cm-1 to 3,367.8 cm-1, while other composites were not significantly different. Also, the results of low frequency dry flashover voltages of new and tested samples were 133.8 and 140.0 kV, respectively. The low frequency wet flashover voltages of before and after the wheel tested was 115.5 and 107.3 kV, respectively. Finally, the impulse flashover voltage test shown that the positive “polarity lightning impulse voltages of the new and tested samples were 235.4 and 231.53 kV, and the negative” polarity lightning impulse voltages were 261.9 and 256.4 kV, respectively.
PL
Niniejsze badanie ma na celu przetestowanie izolatorów polimerowych wysokiego napięcia (WN) w celu zbadania wydajności elektrycznej i pogorszenia się powierzchni izolatora w warunkach testu koła. Próbki z tego badania to cztery nowe gumy silikonowe z izolatorami prętowymi z tworzywa sztucznego wzmocnionego włóknami, model FXB 22/70 22 kV, które zostały losowo wyselekcjonowane z rynku komercyjnego w Tajlandii. Eksperymenty w tych badaniach to zgodne z normą IEC/TR 62730 polimerowe izolatory wysokiego napięcia do badań metoda karuzelowa w pomieszczeniach. Wyniki wykazały, że rezystancja próbek przed i po teście kołowym 30 000 cykli ma mniejszą rezystancję odległości 10 mm na próbkach odpowiednio 37,0 i 7,76 G. Rezystancje próbki były wyższe niż rezystancje 2 M, głębokość erozji mniejsza niż 3 mm i brak przebicia na osłonie, obudowie lub interfejsie, zgodnie z kryteriami normy IEC/TR 62730. Co więcej, hydrofobowość próbek przed i po obróbce została zmniejszona z HC 1 do HC 6, które sklasyfikowano według przewodnika STRI. Średnie prądy upływu pierwszego testu koła 10 000 i 30 000 cykli wynosiły odpowiednio 0,037 mA i 0,074 mA. Podczas gdy po 6000 cykli testu termografia wykazała, że obszary na końcu izolatora w pobliżu zacisku uziemienia miały wyższą temperaturę niż inne, w przeciwnym razie po 30 000 cyklach testu temperatury izolatora były wyższe na rdzeniu pręta. Co więcej, fotografia 1000x SEM pokazała, że trzy próbki wycięte (przygotowane) powierzchni nowego izolatora były gładkie. Po 15 000 cykli skóra starzeje się bardziej i głębsze tekstury po 30 000 cyklach testowania. Poza tym spektroskopia w podczerwieni z transformacją Fouriera wykazała, że ATH próbek przed i po obróbce zmniejszyło się z 3445,4 cm-1 do 3367,8 cm-1, podczas gdy inne kompozyty nie różniły się istotnie. Również wyniki napięć suchego przeskoku niskoczęstotliwościowych próbek nowych i badanych wyniosły odpowiednio 133,8 i 140,0 kV. Napięcia przebicia mokrego o niskiej częstotliwości przed i po badanym kole wynosiły odpowiednio 115,5 i 107,3 kV. Wreszcie, test napięcia udarowego przeskoku wykazał, że dodatnie „napięcia udaru piorunowego polaryzacji nowych i badanych próbek wyniosły 235,4 i 231,53 kV, a ujemne” napięcia udaru piorunowego polaryzacji wyniosły odpowiednio 261,9 i 256,4 kV.
2
Content available remote Łańcuchy złożone z izolatorów kompozytowych i kołpakowych
PL
Artykuł opisuje łańcuchy linii wysokonapięciowych składających się z izolatora kompozytowego i izolatorów kołpakowych. Szeregowo połączony izolator kołpakowy nie tylko wyrównuje rozkład napięcia wzdłuż izolatora kompozytowego ale także obniża natężenie pola elektrycznego na izolatorze polimerowym. Ceramiczny izolator kołpakowy może dodatkowo być wykorzystany jako wskaźnik uszkodzenia izolatora kompozytowego.
EN
This paper describes high voltage insulator chains consisted of one composite insulator and cap and pin insulators. The cap and pin insulator connected in series not only equalizes the voltage distribution along the composite insulator but also reduces the electrical field intensity at the polymer insulator. The ceramic disc insulator can be additionally applied as an indicator of composite insulator failure.
EN
The increased interest in transmission of electricity by using high DC voltage forced the need to examine the ageing resistance of silicone rubber insulators exposed to high DC voltage. Under operating conditions, in the presence of a high DC voltage due to electrostatic phenomena is observed even a fourfold increase in the accumulation of contaminants on the surface of the insulator compared to the high AC voltage. Lack of crossing zero values by current and voltage curves favors to the maintenance of surface discharges concentrated especially in the presence of water. In the paper tests results of the model composite insulators with different inclination of upper surface sheds in the clean fog chamber under high DC voltage is described. The aim of the research is to recognition of degradation ageing process of composite insulators electric properties and the phenomena of leakage current development. Laboratory test results allow to inference about the influence of the shape and design parameters of sheds on the behavior of the silicone composite insulators in operation. ().
PL
W artykule przedstawiono wyniki rozkładów napięcia na połączonych w łańcuch izolatorach: kompozytowym na 110 kV i pojedynczym izolatorze kołpakowym pokrytym warstwą silikonu RTV. Zasymulowano zmianę właściwości powierzchniowych izolatorów w czasie eksploatacji. Stwierdzono, że dołączenie do izolatora kompozytowego niewielkiego izolatora ceramicznego, powleczonego silikonem RTV, w istotny sposób łagodzi występującą na izolatorze kompozytowym nierównomierność rozkładu napięcia.
PL
Artykuł zawiera opis prac wykonanych przez autorów dotyczących prób i oceny rdzeni szkłoepoksydowych stosowanych w izolatorach kompozytowych napowietrznych średniego napięcia. Autorzy wykonali szereg pomiarów i sprawdzeń rdzeni o różnych średnicach, obejmujących próby według wytycznych zawartych w normach, a także dodatkowych prób opracowanych wg własnego programu. Publikacja zawiera opisy i wyniki wykonanych badań prętów i rdzeni szkłoepoksydowych.
EN
The article contains description of tests and rating GFRP cores for composite insulators. Authors have done many measurements and checks of cores with different diameters, including tests according to the guidelines contained in the standards, as well as additional tests designed by them. The publication contains descriptions and results of the fiber glass cores tests.
PL
W artykule przedstawiono wyniki badań powierzchniowych wyładowań niezupełnych na izolatorze odciągowym kompozytowym linii średniego napięcia. Badania zostały wykonane podczas różnych stopni zabrudzenia izolatora substancją przewodzącą w postaci roztworu NaCl. Wyniki pomiarów przedstawione zostały za pomocą obrazów światła widzialnego nałożonego na emisję promieniowania elektromagnetycznego w zakresie UV generowanego przez wyładowania niezupełne.
EN
Presented are investigation results of surface partial discharges taking place on a MV overhead power line strain composite insulator. The investigations were conducted under conditions of various degrees of the insulator soiling with conductive material used in a form of NaCl solution. Measurements results were presented with the help of visible light images superimposed on the electromagnetic radiation emission in the UV range generated by partial discharges.
6
Content available remote Wyładowania niezupełne na izolatorach kompozytowych
PL
W artykule przedstawiono wyniki badań porównawczych powierzchniowych wyładowań niezupełnych na modelowych izolatorach kompozytowych z osłoną z kauczuku silikonowego typu HTV o różnym kształcie osłon i różnym stopniu zestarzenia ich powierzchni. Wykazano, że wyniki pomiarów wyładowań niezupełnych mogą być wykorzystane w ocenie diagnostycznej stanu powierzchni izolatorów kompozytowych z eksploatacji.
EN
In the paper results of the comparison tests of the partial discharges on the surface of model HTV composite insulators were shown. Insulators differed in shape of housings and degree of aging their surfaces. It has been shown that the results of the measurement of partial discharges can be used in the diagnostic evaluation of composite insulators in service.
7
Content available remote Zanik ładunku na izolatorach kompozytowych
PL
Zbadano proces zaniku ładunku powierzchniowego na cylindrycznych kompozytowych izolatorach zawierających różne kombinacje materiałów rdzenia i płaszcza. Izolatory zostały poddane „punktowej” elektryzacji za pomocą wyładowania koronowego przy napięciu stałym. Wyniki badań wykazały zależność szybkości zaniku ładunku od materiału płaszcza jak i rdzenia przy czym transport ładunku ma miejsce głównie w płaszczu. Stwierdzono również wpływ interfazy rdzeń-płaszcz na szybkość zaniku ładunku.
EN
Surface charge decay process was examined on cylindrical composite insulators models with various combinations of core and housing materials. Insulator models were subjected to “point” electrification by DC corona discharge. The results showed that the rate of charge decay depend on the material of the core and the housing wherein the charge transport takes place primarily in the housing. It was also found the influence of core-housing interphase on the rate of charge decay.
PL
Znormalizowane metody prób kompozytowych wsporczych izolatorów stacyjnych sprowadzają się wyłącznie do obciążeń statycznych. W eksploatacji występują jednak zarówno obciążenia statyczne, jak i zmienne. Są to głównie obciążenia zginające. Obciążenia zginające powodują ugięcie izolatorów kompozytowych znacznie większe, niż izolatorów ceramicznych. Stąd konieczność wprowadzenia nieznormalizowanych wymagań w zakresie ich dopuszczalnego ugięcia i odporności na obciążenia zmienne.
EN
Standard methods for testing composite station post insulators combine static loads only. However under operation conditions these insulators are subjected to static and variable loads. These are mainly cantilever loads. Bending of composite station post insulator can be much biger than for ceramic ones. Introduction of non standard tests and requirements for evaluation of permissible bending limits and resistance to variable loads for these insulators is necessary.
EN
This paper presents the mechanism of a sudden flashover along composite insulator surface with non-uniformly distributed wettability and pollution. Parameters of the model have been determined on the basis of typical composite insulator pollution characteristics in a condition of low or high surface wettability. It has been found that surface strength of composite insulator with non-uniformly distributed wettability and pollution depends mainly on a part of its creepage distance (of low wettability) – around 25% of insulator’s overall creepage distance.
PL
W artykule przedstawiono mechanizm natychmiastowego przeskoku napięciowego po powierzchni izolatora kompozytowego o nierównomiernej zwilżalności i nierównomiernym zabrudzeniu. Parametry modelu określono na podstawie typowych charakterystyk zabrudzeniowych izolatora kompozytowego w stanie niskiej lub wysokiej zwilżalności. Stwierdzono, że wytrzymałość powierzchniowa izolatora kompozytowego zależy głównie od części jego drogi upływu (około 25% całkowitej długości) wzdłuż powierzchni o niskiej zwilżalności.
PL
W artykule przedstawiono zachowanie się kropli wody zwilżających powierzchnię osłony izolatora kompozytowego. Opisano wpływ nachylenia kloszy izolatorów i ich pozycji pracy na dynamikę starzenia i wzrost wartości prądu upływu izolatorów. Stwierdzono, że parametry konstrukcyjne kloszy izolatora i rodzaj opadów wpływają na ilość kropli wody zwilżających powierzchnię izolatora. Ilość wody akumulowanej na kloszach w warunkach opadu sztucznego deszczu może być wykorzystana jako kryterium przy optymalizacji kształtu osłon izolatorów.
EN
In the paper behaviour of a water droplets wetting the composite insulator housing surface were presented. Influence of the insulators sheds inclination and their operate position on dynamics of ageing and leakage current increase were described. It was found that design parameters of the insulators sheds and type of precipitation influence on amount of the water drops wetting the insulator surface. The accumulation of water wetting the composite insulators sheds in artificial rain conditions can be use as a criteria of the insulators housing shape optimization.
PL
W artykule oceniono przydatność ceramicznych i nieceramicznych (głównie kompozytowych) izolatorów stacyjnych i liniowych w sieciach SN i 110 kV. Przedstawiono zalety wybranych rozwiązań układów izolacji liniowej i stacyjnej oraz obawy towarzyszące zastosowaniu konkretnego układu izolacyjnego. Zbiór zalet i wad wynikających z zastosowania poszczególnych rodzajów izolacji tworzy zarys kryteriów wyboru konkretnego rodzaju układu izolacyjnego, przeznaczonego do określonego zastosowania. Ze względu na różne wymagania i specyfikę pracy, izolacja stacyjna i liniowa analizowana jest oddzielnie.
EN
Usefulness of ceramic and non-ceramic insulators (mainly composite ones)as line and station power insulators in MV and 110 kV networks is assessed in the article. The following aspects have been considered: advantages of chosen solutions of line and station power insulation and thread resultant from application of specific type of an insulating system. A set of advantages and faults (threats) of particular types of insulating systems creates an outline of criteria for choice of specific insulating system destined for a given application. For the sake of different requirements and operation specificity station and line insulation is analyzed separately.
PL
Izolatory kompozytowe, charakteryzujące się właściwościami odmiennymi od konwencjonalnych izolatorów elektroenergetycznych, są stosowane coraz szerzej. W artykule w zwięzły sposób przedstawiono metodykę projektowania i konstruowania ceramicznych i kompozytowych izolatorów liniowych wysokiego napięcia oraz porównano zasady projektowo-konstrukcyjne dotyczące rozważanych grup izolatorów, istotnych ze względu na rosnące wciąż wymagania techniczne i niezawodnościowe.
EN
Composite insulators, characterized by properties different from conventional power transmission insulators, are used more widely. The article presents a concise methodology for the design and construction of ceramic and composite insulators of high voltage lines. The principles of design and construction of considered groups of insulators, important because of the growing technical and reliability requirements were compared.
13
Content available remote O problemie oceny stanu technicznego eksploatowanych izolatorów kompozytowych
PL
W artykule przedstawiono problem oceny stanu izolatorów kompozytowych eksploatowanych w liniach elektroenergetycznych na podstawie wyników badań laboratoryjnych reprezentatywnej grupy izolatorów zdemontowanych z linii. Przedstawiono ich typowe uszkodzenia eksploatacyjne oraz program badań odpowiadający zagrożeniom eksploatacyjnym spotykanym w warunkach krajowych. Zaproponowano procedurę badawczą oraz schemat oceny izolatorów.
EN
The paper discusses the problem of technical state evaluation of exploited composite insulators. The state evaluation was performed on the base of laboratory tests of a representative group of insulators removed from the line. Typical in-service damages and the research program corresponding to exploitation exposures met in domestic conditions were also presented. The test procedure and the diagram of examinations were proposed.
PL
W artykule przedstawiono konstrukcje kloszowe silikonowych izolatorów kompozytowych, dostępnych na rynku europejskim. Na podstawie wyników laboratoryjnych badań modelowych izolatorów kompozytowych opisano procesy degradacji właściwości powierzchniowych izolatorów w warunkach działania wysokiego napięcia i opadów wody symulujących deszcze i mgły. Zwrócono uwagę na zależność tych procesów od parametrów konstrukcyjnych kloszy i układów kloszowych oraz podano wnioski praktyczne.
EN
In the paper sheds constructions of composite insulators available on European market were presented. Based on the laboratory tests results of the composite model insulators degradation processes of insulators surface properties in presence of high voltage and water precipitation were described. It was pointed on dependence of these processes on structural parameters of the sheds and the sheds arrangement. Practical conclusions were also given.
PL
Wsporcze izolatory stacyjne są narażone głównie na obciążenia zginające. Przy dużych prądach zwarcia zmienne siły zginające izolator mogą osiągać wartości przekraczające znamionową wytrzymałość izolatorów. Rozpoczęte w Instytucie Energetyki prace nad wytrzymałością izolatorów wsporczych przy cyklicznym obciążeniu zginającym powinny pozwolić na sformułowanie kryterium doboru kompozytowych izolatorów wsporczych do pracy w warunkach narażenia na obciążenia zmienne, a także na przyjęcie odpowiednich wymagań dla tego rodzaju izolatorów.
EN
Station post insulators are mainly subjected to cantilever loads. At high values of short-circuit currents the dynamic cantilever loads can reach values higher than specified cantilever loads. At the Institute of Power Engineering (IEn) has been recently taken up research works on mechanical strength of composite station post insulators subjected to cyclic cantilever loads.
16
PL
W artykule przedstawiono metodykę badań diagnostycznych eksploatowanych izolatorów kompozytowych opracowaną w Laboratorium Techniki Wysokich Napięć Politechniki Wrocławskiej. Stwierdzono, że laboratoryjne badania diagnostyczne eksploatowanych izolatorów kompozytowych, obejmujące w szczególności próby w wysokonapięciowej komorze mgielnej, stromo narastającymi udarami napięciowymi oraz statycznej wytrzymałości mechanicznej, umożliwiają kompleksową ocenę stanu technicznego izolatorów.
EN
In the paper a methodology of diagnostic test of exploited composite insulators drawn up in the Laboratory of the Technique of High Voltages of the Wroclaw Technical University was described. It was stated, that laboratory diagnostic tests of exploited composite insulators, including tests in the high voltage fog chamber, with steeply increasing voltage surges and of static mechanical strength, enable the comprehensive evaluation of the technical condition of insulators.
PL
W artykule dokonano oceny wpływu położenia pracy wybranych modelowych izolatorów kompozytowych na utratę ich właściwości powierzchniowych w warunkach działania wysokiego napięcia i opadów czystej mgły. Przedstawiono wyniki badań napięcia przeskoku elektrycznego na wstępnie postarzonych i zwilżonych izolatorach. Nie stwierdzono wpływu degradacji właściwości osłon we wstępnym etapie starzenia na wytrzymałość elektryczną izolatorów.
EN
This paper describes results of tests performed on model composite insulators having different shape of silicone housings. The insulators were stressed by high voltage under rain or clean fog in vertical and horizontal positions. After initial ageing period the measurements of flashover voltage on the wetted insulators were made. Influence of insulators operates position on the loss their surface properties and electric strength were estimated.
PL
W artykule przedstawiono wyniki badań modelowych izolatorów kompozytowych różniących się parametrami geometrycznymi osłon starzonych w wysokonapięciowych komorach mgielnej i deszczowej. Porównywano wpływ średnicy kloszy izolatorów na ich odporność starzeniową. Izolatory badano w pionowym, ukośnym oraz poziomym położeniu pracy.
EN
In the paper tests results of model composite insulators with different shape of their housings in high voltage fog and rain chambers were presented. Influence of insulators sheds diameter on the ageing resistance was compared. Insulators were tested in vertical, incline and horizontal positions
PL
W artykule opisano wpływ zachowania się kropli wody osadzonych na powierzchni wstępnie postarzonych izolatorów kompozytowych na wystąpienie przeskoku elektrycznego. Przedstawiono rejestracje fotograficzne i filmowe zjawisk: zwierania odstępów międzykloszowych, wyładowań iskrowych między spadającymi z kloszy kroplami wody oraz rozwoju elektrycznych wyładowań powierzchniowych.
EN
In this paper results of laboratory tests initially aged composite insulators were described. Influence of the water drop behavior on the electric flashover occurrence was tested. Photographic and movie registration of the following phenomena were showed: water bridges formation between sheds, spark discharges between falling drops of water and development of the surface electric discharges.
PL
Przedstawiono wyniki badań modelowych izolatorów kompozytowych w próbach starzeniowych w komorach deszczowej i mgielnej. Wykazano wpływ kąta nachylenia kloszy i położenia pracy izolatorów na dynamikę wzrostu powierzchniowych prądów upływu. Opisano zjawiska zwilżania powierzchni osłon izolatorów i rozwoju procesów starzeniowych.
EN
In the paper ageing tests results of model composite insulators in the fog and rain chambers were presented. Influence of insulator sheds inclination and operation position on dynamics of ageing process development and leakage current increase were described. Influence of insulator operation positions and type of precipitation (fog or rain) on the way of their surface wetting were tested.