Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  izolacja wysokonapięciowa
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Profesor Jerzy Ignacy Skowroński, nauczyciel i autorytet
PL
Przedstawiono najważniejsze osiągnięcia naukowe Prof. J.I. Skowrońskiego przed 1939 rokiem i po wojnie. Opisano wspomnienia o Profesorze Jego asystenta, dr inż. Andrzeja Adama Zelka uzupełnione cytatami z Jego prac. Podkreślono autorytet Prof. Skowrońskiego jakim cieszył się wśród swoich uczniów, współpracowników i studentów.
EN
The most important scientific achievements of Prof. J.I. Skowronski were presented before 1939 and after the WWII. The memories of His assistant, Dr. Andrzej Adam Zelek, were described, supplemented by quotations from Professor’s works. Prof. Skowronski's authority among his students, co-workers and students was emphasized.
2
Content available remote Autotransformers for power systems
EN
When the primary and secondary voltages are obtained from the same winding, or from two windings which are galvanically connected, such a transformer is called an autotransformer. The paper will focus on fundamentals, design and applications of autotransformers of core-type design. The selected problems of insulating system will be discussed (e.g. end fed vs center fed HV lead bring out, stresses in the end insulation). Examples of the lightning impulse voltage distributions for different winding arrangements will be shown. Operational overvoltages will be also discussed.
PL
Transformator, w którym napięcie pierwotne i wtórne są pobierane z jednego uzwojenia lub z dwóch uzwojeń galwanicznie połączonych ze sobą, jest nazwany autotransformatorem. Artykuł omawia podstawy, konstrukcje i zastosowanie autotransformatorów o budowie rdzeniowej. Omówione zostaną wybrane zagadnienia układu izolacyjnego (np. porównanie różnych sposobów wyprowadzeń przewodu liniowego WN, naprężenia w izolacji końców uzwojeń). Przykładowe rozkłady napieć udarowych będą także omówione.
EN
The paper presents a computer application developed for analysis of acoustic emission signals accopanying the process of electric treeing occurring in polymeric materials, and in particular epoxy resins used as high-voltage solid insulation. A method for measuring, recording and registration of signals was presented. In particular,it is shown how the developed application uses wavelet transformation to remove noise from the recorded signal, and to carry out a time-frequency analysis of these signals. The results of the sample analysis of the recorded signals were also shown.
PL
W artykule zaprezentowano aplikację komputerową opracowaną w celu analizy sygnałów emisji akustycznej towarzyszących procesowi drzewienia elektrycznego materiałów polimerowych, w szczególności żywic epoksydowych stosowanych jako wysokonapięciowa izolacja stała. Zaprezentowano sposób pomiaru, rejestracji i rejestracji sygnałów. W szczególności pokazano w jaki sposób opracowana aplikacja wykorzystuje transformację falkowa do usunięcia szumów z zarejestrowanego sygnału, a także do prowadzenia analizy czasowo-częstotliwościowej tych sygnałów. Pokazano również wyniki przykładowej analizy zarejestrowanych sygnałów.
EN
The experiences of the author, gained during the measurements of partial discharges using DDX 7000 instrument, are presented in this article. The experiences concern the measurements carried out on the real electrical objects such the inductive voltage transformers. The measurement systems and procedures, and the methods of the visualization of the results obtained using DDX 7000 are also presented.
PL
W artykule przedstawione zostały doświadczenia autora związane z pomiarami wyładowań niezupełnych z użyciem detektora DDX 7000. Doświadczenia te dotyczą pomiarów wykonanych na rzeczywistych obiektach, którymi były indukcyjne przekładniki napięciowe. Zaprezentowano układy i procedury pomiarowe oraz metody wizualizacji wyników pomiarów uzyskanych z wykorzystaniem urządzenia DDX 7000.
PL
W pracy przedstawiono wyniki badań związanych z wykorzystaniem metody emisji akustycznej w detekcji procesu drzewienia elektrycznego dielektryków stałych. Podano opis wykorzystanego w badaniach stanowiska pomiarowego oraz opracowane i stosowane metody analizy zarejestrowanych sygnałów. Przedstawiono przykładowe wyniki badań próbek polimetakrylanu metylu oraz polietylenu sieciowanego. Wskazano na możliwość zastosowania metody emisji akustycznej do detekcji procesu drzewienia oraz przedstawiono zależności pomiędzy wybranymi parametrami sygnałów a obecnością i intensywnością procesu drzewienia.
EN
The paper presents use of the acoustic emission (AE) method in the study of electrical treeing process in solid dielectrics. The second section presents a measurement stand and the way of preparing samples for testing. The third section contains a summary description of the AE signal analysis and sample results for methyl polymethacrylate (crosslinked polyethylene also was tested). The studies showed the presence of EA signals associated with electrical treeing process. Initiation of this process is accompanied by increase in the counts and events rate of EA. These indicators remain at a high level during treeing. When the process stops, their values decrease. The significant increase in the signal RMS value means intense treeing. The frequency and time - frequency analysis can show the dominant frequency in the signal during treeing. And so, treeing in methyl polymethacrylate is accompanied by signals from the range 40 - 50 kHz, while signals accompanying treeing in crosslinked polyethylene are from the range 20 - 30 kHz.
6
Content available remote Moisture in high voltage power transformers in service
EN
Hydro One fleet of 500 kV, 750 MVA autotransformers was experiencing problems in service due to the high moisture content in the transformer insulation system. Failure rate was unacceptably high with the record of one failure per two years. The purpose of this investigation was the assessment of the moisture content in the transformers solid insulation based on (i) moisture content in transformer oil, (ii) direct moisture measurements in insulation samples and (iii) statistical analysis of moisture activity over long period of time. As a result, on site dry-out plan was established and close monitoring of the critical units took place.
PL
W czasie eksploatacji autotransformatorów energetycznych na napięcie 500 kV i mocy 750 MVA, będących w posiadaniu firmy Hydro One, spotkano się z problemem zawilgocenia ich układu izolacyjnego. Współczynnik uszkadzalności osiągnął niemożliwą do zaakceptowania wartość jednej awarii w ciągu dwóch lat. Celem wykonanych badań była ocena zawartości wody w izolacji stałej transformatorów na podstawie (i) zawartości wody w oleju, (ii) pomiarze wilgoci w pobranych próbkach izolacji stałej, (iii) analizie statystycznej oddziaływania wilgoci na izolację w długim czasie obserwacji. Zaproponowano plan suszenia transformatorów w miejscu ich zainstalowania oraz wprowadzono procedurę ścisłego monitorowania jednostek znajdujących się w najgorszym stanie.
EN
The paper presents development of measurement and analysis methods of partial discharges from the point of view of high voltage insulating systems diagnostic. The application of digital signal processing methods in partial discharge measurements enables improvement of PD detection sensitivity and gives new possibilities of the PD pattern interpretation for both physical mechanisms investigations and assessment of PD development in insulating systems at in-service stresses. Authors present results of researches connected with: analysis of phase-resolved patterns of partial discharge pulses; the methods of signal-to-noise improvement; the influence of AC voltage distortion by the higher harmonics; and also possibilities of detection and analysis of PD at low frequency voltages, and in conditions of very fast voltage pulses.
PL
układów izolacyjnych. Zastosowanie metod cyfrowego przetwarzania sygnałów w pomiarach wnz pozwala zwiększyć czułość detekcji impulsów wyładowań oraz daje nowe możliwości interpretacji obrazów wnz zarówno dla badań mechanizmów fizykalnych tych zjawisk, jak i dla oceny ich rozwoju w układach izolacyjnych pod działaniem narażeń eksploatacyjnych. Autorzy przedstawiają wyniki badań związanych z: analizą obrazów fazowo-rozdzielczych impulsów wyładowań niezupełnych, metodami poprawy stosunku sygnał/szum, wpływem odkształceń napięcia przemiennego przez wyższe harmoniczne, a także możliwościami detekcji i analizy wnz przy obniżonej częstotliwości i w warunkach działania szybkozmiennych impulsów napięciowych.
8
Content available remote Application of many neural networks paradigms for the high voltage insulation
EN
An application of some artificial neural networks algorithms to the diagnosis of transformer oil and high voltage insulation thermal ageing prediction has been presented. An RBFG neural network trained by Random Optimisation Method has been applied for prediction and a Back-Propagation network trained by Levenberg-Marquardt technique has been used for diagnosis. The simulation had been validated by experimental results carried out in the National Algerian Company of Electricity and Gas, the national company of cable and the high voltage laboratories of the Warsaw University of Technology.
PL
W artykule przedstawiono zastosowanie algorytmów sieci neuronowych w diagnostyce oleju transformatorowego oraz prognozowaniu starzenia termicznego izolacji wysokonapięciowej. Do celów prognozowania zastosowano sieć neuronową podstawowej funkcji radialnej Gaussa trenowaną metodą optymalizacji stochastycznej a dla celów diagnostyki sieć neuronowa propagacji zwrotnej trenowaną techniką Lavenberga-Morquardta. Symulacje potwierdzone zostały wynikami eksperymentów przeprowadzonych w Algierskim Narodowym Przedsiębiorstwie Elektryczności i Gazu, Narodowym Przedsiębiorstwie Kablowym oraz w laboratorium WN Politechniki Warszawskiej.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.