EN
Fire doors play a key role in the fulfilment of the requirement for ensuring efficient and safe evacuation in case of fire. In fire conditions, they are to form a barrier to fire, smoke and heat. Therefore, this type of items should be appropriately fire-rated with respect to fire integrity, fire insulation and smoke control. This article discusses the main aspects of heat flow stopping, i.e. fire insulation of hinged aluminum, profiled fire doors depending on the fire exposure side. The results were compared of temperature increase on aluminum profiles in the case of several types of fire doors with symmetrical cross-sections of the profiles (two possible cases of fire exposure) and fire doors with asymmetrical cross-sections of the profiles (four fire cases possible). The items selected for each comparison were made in the same way in all respects, with the fire direction being the only difference.
PL
Drzwi przeciwpożarowe odgrywają kluczową rolę w spełnieniu wymagania dotyczącego zapewnienia sprawnej i bezpiecznej ewakuacji w przypadku pożaru. W warunkach pożaru powinny stanowić barierę dla ognia, dymu i ciepła. Muszą więc mieć odpowiednią odporność pod względem szczelności ogniowej, izolacyjności ogniowej i dymoszczelności. W artykule omówiono główne aspekty wpływające na przepływ ciepła, tj. izolację ogniową aluminiowych, uchylnych, profilowych drzwi przeciwpożarowych w zależności od strony narażenia na ogień. Porównano wyniki wzrostu temperatury na profilach aluminiowych w przypadku kilku typów drzwi przeciwpożarowych o symetrycznych przekrojach profili (dwa możliwe przypadki narażenia na ogień) oraz drzwi przeciwpożarowych o niesymetrycznych przekrojach profili (cztery przypadki możliwego pożaru). Badane elementy do każdego porównania zostały wykonane w ten sam sposób, a jedyną różnicą był kierunek oddziaływania ognia.
PL
Artykuł omawia wybrane zagadnienia dotyczące łączenia kabli i przewodów oraz prowadzenia tras kablowych w strefach pożarowych i zagrożonych wybuchem.
EN
The article discusses selected issues concerning the cable routing in areas endangered with fire and explosion.
EN
The inner walls of a building, which do not constitute its structure and therefore do not have loadbearing properties, are called partition walls. The main task of this type of element is the separation of rooms in a building, which is why they should be designed and constructed in a way that ensures, among others, compliance with fire safety requirements, including those related to fire resistance. There are many types of fire-resistant partition walls both on the European and global construction market, among which the most impressive effect is achieved by those using glass elements in their structure. These include aluminium glazed partitions, which are the subject of this paper. These structures are usually made of special fire-resistant glass positioned in three chamber profiles, made of two aluminium sections, connected by a thermal break, usually made of glass fibre reinforced polyamide. The chambers created in this way are filled with special insulating inserts, and the degree of filling depends on the expected fire resistance class, which is determined by an appropriate test. Large wall-height profiles of this type are usually further reinforced by screwing to them additional, special aluminium profiles. In this paper, the impact of using this type of additional profiles on the fire resistance of a glazed wall was analysed. The results of two walls with identical external dimensions and the same static scheme, made on the basis of the same glazing, from the same aluminium profiles have been compared, with additional reinforcing profiles applied in one of the tests. This article discusses the results obtained and the conclusions from the tests conducted.
PL
Ściany wewnętrzne budynku, które nie stanowią jego konstrukcji, a tym samym nie mają właściwości nośnych, nazywane są ścianami działowymi. Głównym zadaniem tego typu elementów jest wydzielenie pomieszczeń w budynku, dlatego należy je projektować i wykonywać w sposób zapewniający m.in. zachowanie wymagań bezpieczeństwa pożarowego, w tym w zakresie odporności ogniowej. Na europejskim, a także światowym rynku budowlanym istnieje wiele rodzajów przeciwpożarowych ścianek działowych, z których najbardziej spektakularny efekt osiągają te, które wykorzystują w swojej konstrukcji elementy szklane. Należą do nich przeszklone przegrody aluminiowe które są przedmiotem niniejszego artykułu. Konstrukcje te są zwykle wykonane ze specjalnego szkła odpornego na działanie ognia, umieszczonego w trójkomorowych profilach składających się z dwóch profili aluminiowych, połączonych przekładką termiczną, najczęściej z poliamidu wzmocnionego włóknem szklanym. Powstałe w ten sposób komory wypełnione są specjalnymi wkładami izolacyjnymi, a stopień wypełnienia jest uzależniony od oczekiwanej klasy odporności ogniowej, która jest określana odpowiednim badaniem. Tego typu profile o dużej wysokości ścian są zwykle dodatkowo wzmacniane poprzez przykręcenie do nich specjalnych profili aluminiowych. W artykule przeanalizowano wpływ zastosowania tego typu dodatkowych profili na odporność ogniową przeszklonej ściany. Porównano wyniki dwóch ścian o identycznych wymiarach zewnętrznych i tym samym schemacie statycznym, wykonanych na podstawie tego samego schematu oszklenia, z tych samych profili aluminiowych, z dodatkowymi profilami wzmacniającymi zastosowanymi w jednym z badań. W artykule omówiono uzyskane wyniki oraz wnioski z przeprowadzonych badań.