Mechanical properties of FRP such as strength and stiffness as well as the bonding interface between FRP and concrete will be badly deteriorated when exposed to high temperature. Furthermore, the effect of thickness of insulation with different type of concrete strength has not yet been studied elsewhere in numerical studies. Therefore, this study is to assess the thermal-structural behaviour of insulated FRP strengthened RC beam exposed to elevated temperature using ABAQUS. The proposed numerical model of 200×300 mm RC beam subjected to 2 hours standard fire curve (ISO 834) had been validated with the analytical solution. The validated numerical model then is used in parametric study to investigate the behaviour of fire damaged normal strength concrete (40 MPa) and high strength concrete (60 MPa) of RC beam strengthened with CFRP using various fire insulation thickness of 12.5 mm, 25 mm and 40 mm, respectively. The result of steel characteristic strength reduction factor is compared with analytical using 500°C Isotherm methods. The parametric studies indicated that the fire insulation layer is essential to provide fire protection to the CFRP strengthened RC beams when exposed to elevated temperature. The insulation layer thickness of 25 mm had been found to be the optimum thickness to be used as it is able to meet the criteria of temperature distribution and displacement requirement. In conclusion, the numerical model developed using ABAQUS in this study is to carry out assessment on the thermal-structural behaviour of the insulated CFRP-strengthened RC beams at elevated temperature.
PL
W artykule przedstawiono ocenę niezidentyfikowanych z nazwy pasywnych izolacji ogniochronnych konstrukcji stalowych po upływie czasu. Opisano metody oceny trwałości tych zabezpieczeń w oparciu o badania in situ i badania laboratoryjne pobranych próbek. Przedstawiono obliczeniową metodę oceny odporności ogniowej elementów konstrukcji stalowych zabezpieczonych tymi materiałami.
EN
This article presents an assessment of unbranded passive steel structure fireproofing systems after a certain time. Methods for assessment of durability of these products are presented, both laboratory and in situ tests. Moreover, a calculation method for assessment of fire resistance properties is presented for steel structures protected with these treatments.
EN
Due to its numerous advantages steel it generally applied in the design of building structures. It displays, however, two fundamental drawbacks, viz. it is susceptible to corrosion and not very fireproof. In the case of a conflagration it soon loses resistance and its elements undergo considerable deformations. Both these disadvantages can be minimized by applying adequate safetymeasures. The paper deals with the effect of the physical properties of the material used as fireproof insulation on its effectiveness. Special attention has been devoted to the problem of the increased value (even by several times) of the overall heat-transfer coefficient resulting in a change of temperature.
PL
Przewody wentylacyjne łączą ze sobą pomieszczenia o różnym przeznaczeniu, a także często części budynku znajdujące się w różnych strefach pożarowych. Niewłaściwie zabezpieczone mogą doprowadzić do rozprzestrzeniania się pożaru na pomieszczenia znacznie oddalone od źródła ognia. O konieczności zabezpieczenia przeciwpożarowego przewodów wentylacyjnych mówią stosowne przepisy, z których najważniejszym jest Rozporządzenie Ministra Infrastruktury z dnia 12 kwietnia 2002 r. w sprawie warunków technicznych, jakimi powinny odpowiadać budynki i ich usytułowanie (Dz. U. Nr. 75/02 poz. 690). Rozporządzenie to określa wymaganą klasę odporności ogniowej przewodów wyciągowych dymu, jako co najmniej równą klasie odporności ogniowej (EL) stropu, o ile w budynku nie zastosowano stałych urządzeń gaśniczych w postaci tryskaczy. W obiektach chronionych instalacją tryskaczową klasa odporności ogniowej przewodów instalacji oddymiającej powinna odpowiadać podanym wymaganiom jedynie z uwagi na kryterium szczelności ogniowej (E). Ważny jest również zapis cytowanego rozporządzenia, który mówi o tym że: "pozostałe przewody wentylacyjne i klimatyzacyjne (oile nie są wyposażone w przeciwpożarowe klapy odpinające) prowadzone przez strefę pożarową, której nie obsługują, powinny być obudowane elementami o klasie odporności ogniowej (EL), wymaganej dla elementów oddzielenia przeciwpożarowego tych stref pożarowych."
6
Content available remote Natryskowe powłoki ogniochronne elementów konstrukcji stalowych
7
Content available remote Zabezpieczenia ogniochronne konstrukcji stalowych