Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  iterative control
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Moving average signals for the static compensator control
EN
The shunt static compensator with the control based on the average signals is presented. Two control signals are considered - moving RMS value of grid voltage and moving average power of the energy source. The compensator generates reactive current computed in the real time with the use of the iterative method. The multiport representation of the grid is presented. Analytical and simulation results show how the iterative control of the compensator behaves for three kinds of control signals.
PL
Opisano sterowanie kompensatora statycznego z wykorzystaniem dwóch rodzajów sygnałów – przesuwnej wartości skutecznej napięcia sieci i przesuwnej mocy czynnej źródła energii. Kompensator generuje prąd bierny obliczany w czasie rzeczywistym z wykorzystaniem metody iteracyjnej. Pokazano wielowrotnikową reprezentację sieci elektrycznej. Analityczne i numeryczne wyniki pokazują jak przebiega sterowanie iteracyjne dla dwóch rodzajów sygnałów sterujących.
2
Content available remote Iterative control of the static compensator
EN
The shunt static compensator with the iterative control is presented. The compensator generates reactive current computed in the real time with the use of the iterative secant method. Simulation results for the circuit composed of the three phase grid and DC/AC converter with PWM space vector control are presented. The control signal is acquired from the grid voltage. The RMS value of grid voltage is chosen as the compensator aim.
PL
Opisano układ i sterowanie równoległego kompensatora statycznego. Kompensator generuje prąd bierny obliczany w czasie rzeczywistym z wykorzystaniem metody siecznych. Zaprezentowano wyniki symulacji obwodu złożonego z modelu sieci trójfazowej oraz przekształtnika DC/AC za sterowaniem PWM metodą wektora przestrzennego. Sygnały sterujące uzyskuje się z mierzonej wartości skutecznej napięcia sieci. Funkcją celu jest zadany poziom napięcia w węźle dołączenia kompensatora do sieci.
EN
The feedback control based on the model and method of iterative learning control, which in turn is based on the macroscopic fundamental diagram (MFD), mostly belongs to the classification of single-layer boundary control method. However, the feedback control method has the problem of time delay. Therefore, a feed forward feedback iterative learning control (FFILC) method based on MFD of the multi-layer boundary of single-area oversaturated intersections is proposed. The FFILC method can improve the effectiveness of boundary control and avoid the time-delay problem of feedback control. Firstly, MFD theory is used to determine the MFD of the control area; the congestion zone and the transition zone of the control area are identified; and the two-layer boundary of the control area is determined. Then, the FFILC controllers are established at the two-layer boundary of the control area. When the control area enters into a congestion state, the control ratio of traffic flow in and out of the two-layer boundary is adjusted. The cumulative number of vehicles in the control area continues to approach the optimal cumulative number of vehicles, and it maintains high traffic efficiency with high flow rates. Finally, The actual road network is taken as the experimental area, and the road network simulation platform is built. The controller of the feedforward iterative learning control (FILC) is selected as the comparative controller and used to analyse the iterative effect of FFILC. Improvements in the use of traffic signal control indicators for the control area are analysed after the implementation of the FFILC method. Results show that the FFILC method considerably reduces the number of iterations, and it can effectively improve convergence speed and the use of traffic signal evaluation indicators for the control area.
EN
The iterative control of the power electronic compensator is presented. The method is based on the voltage measurement. The single phase DC/AC inverter with PWM control is considered. The inverter generates the reactive current shifted to voltage. The current amplitude is computed with the use the iterative algorithm based on Euler secant method. The required voltage amplitude is chosen as the objective function and the limits of the compensator current constitute the constraints. The simulation results for the circuit composed of the simple grid model and DC/AC inverter is presented. The DC/AC inverter with the series inductor realize the current source. The simulation are done with the use PLECS program. Sliding DFT seems to be adequate to compute the correct shift angle between voltage fundamental harmonic and compensator current. The simulation shows that the capacitor voltage connected at the DC side of inverter can be maintained by choosing of the power angle between the grid voltage and inverter voltage.
PL
Przedstawiono koncepcję iteracyjnego sterowania układu wytwarzającego prąd bierny. Metoda opiera się na pomiarze napięcia sieci w węźle przyłączenia kompensatora. Rozpatrywany jest jednofazowy przekształtnik DC/AC ze sterowaniem PWM, realizujący sterowane źródło prądu sinusoidalnego przesuniętego względem pierwszej harmonicznej napięcia sieci. Amplituda wytwarzanego prądu jest obliczana z wykorzystaniem algorytmu iteracyjnego. Funkcją celu w tym algorytmie jest zadana wartość amplitudy podstawowej harmonicznej napięcia sieci. Zmienną poszukiwaną w procesie optymalizacji jest rzeczywisty współczynnik równy stosunkowi amplitudy generowanego sinusoidalnego prądu kompensatora do zmierzonej amplitudy podstawowej harmonicznej napięcia sieci. Pokazano możliwość wytworzenia sygnału sterującego przekształtnik AC/DC w kilku krokach metody iteracyjnej. Metodę tą można zakwalifikować do metod siecznych Eulera. Zaprezentowano wyniki symulacji komputerowych układu złożonego z uproszczonego modelu obwodowego sieci, przekształtnika DC/AC ze sterowaniem PWM oraz szeregowo włączoną cewką indukcyjną. Cewka indukcyjna umożliwia realizację źródła prądu i obliczenie sygnału sterującego przekształtnik. Symulacje wykonano z wykorzystaniem języka programowania PLECS. Pokazano możliwości podtrzymywania napięcia kondensatora włączonego po stronie DC przekształtnika za pomocą kąta mocy między napięciem sieci i napięciem przekształtnika.
EN
Interesting structural considerations can be derived from comparison of the topologies and forms of regulators obtained by the pole-placement design, the GTDOF and the MPC. Practical advice is given to the polynomial orders of the MPC. A new simple method is introduced for iterative ID and control based on these findings.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.