Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  ion emission
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper deals with the subject related to the assessment of the influence of the axis angle of the metal components of the hip joint on the emission of cobalt ions. The tribological tests were carried out with the use of a simulator for the examination of hip joint endoprostheses, the structure of which enables the fixation of endoprosthesis components in accordance with the anatomical structure of the human hip joint. During the tests, the simulator performs flexion and extension movements as well as loads occurring in the human hip joint while walking. Loss-wear tests were carried out for nine variants of the “head–cup” system settings. These settings were determined on the basis of CT images obtained from patients after arthroplasty. After the tribological tests were completed, samples of the lubricating fluid with the wear products suspended in it were collected in order to determine the concentration of cobalt ions, which was carried out using the atomic absorption spectrometry method. As a result, the influence of the head antetorsion angle (α) and the acetabular anteversion angle (β) on the concentration of cobalt ions was analysed.
PL
W pracy poruszono problematykę związaną z oceną wpływu kątów elementów endoprotezy stawu biodrowego na emisję jonów kobaltu. Badania tribologiczne przeprowadzono przy użyciu symulatora do badania endoprotez stawu biodrowego, którego konstrukcja umożliwia mocowanie elementów endoprotezy zgodnie z budową anatomiczną stawu biodrowego człowieka. Podczas testów symulator wykonuje ruchy zgięcia i wyprostu oraz obciążenia występujące w stawie biodrowym człowieka podczas chodzenia. Testy zużycia przeprowadzono dla dziewięciu wariantów ustawień układu „głowa–panewka”. Ustawienia te zostały określone na podstawie obrazów CT uzyskanych od pacjentów po endoprotezoplastyce. Po zakończeniu badań tribologicznych pobrano próbki cieczy smarującej z pozostałymi w niej produktami zużycia w celu oznaczenia stężenia jonów kobaltu, co przeprowadzono metodą atomowej spektrometrii absorpcyjnej. W rezultacie przeanalizowano wpływ kąta antetorsji głowy (α) i kąta antewersji panewki (β) na stężenie jonów kobaltu.
EN
Energetic ions emitted from plasmas produced by the interaction of intense laser pulses with solid targets are currently a subject of growing interest due to the possibility of unique applications in accelerator technology, nuclear physics, material science and medicine. Depending on the kind of application, different parameters of the ion fluxes are required, and various conditions of laser-target interaction must be considered. In this paper, selected results of our recent studies of ion emission from plasmas produced by laser pulses of duration from ~ 1 ps to ~ 1 ns and of intensities from 10^10 W/cm^2 to 10^17 W/cm^2 are reviewed. The characteristics of both heavy ion fluxes emitted from massive high-Z targets and proton beams generated from thin foil targets of various structures are presented. Some basic properties of ion fluxes produced in various experimental conditions are discussed. The effect of external magnetic field on the ion emission is demonstrated.
3
Content available remote Positive and negative ion production in the ion sputtering process
EN
To study the secondary ion emission the special apparatus had been designed and constructed by which measurements of current intensity of positive and negative ions generated in this process were performed. The article presents the characteristics of current intensities of positive and negative ions sputtered from a source in dependence on the energy and intensity of bombarding argon ions, voltage and current of arc discharge as well as extraction voltage of ions from the area of a sputtered electrode. From these characteristics the coefficients of secondary ion emission were determined for Al, Ti and Cu targets. It has been shown that the constructed apparatus can be also used for production of positive and negative ions for ion implantation purposes.
PL
W celu badania wtórnej emisji jonowej zostało zaprojektowane i wykonane stanowisko pomiarowe, za pomocą którego przeprowadzono pomiary natężeń prądów jonów dodatnich i ujemnych powstających w tym procesie. Artykuł prezentuje charakterystyki natężeń prądów jonów dodatnich i ujemnych uzyskiwanych ze źródła w zależności od energii i natężenia bombardujących jonów argonu, napięcia i prądu anodowego wyładowania łukowego oraz napięcia ekstrakcyjnego, wyciągającego jony z obszaru elektrody rozpylanej. Na ich podstawie określono współczynniki wtórnej emisji jonowej dla Ar,Ti i Cu. Pokazano, że zbudowane urządzenie można wykorzystać do produkcji jonów dodatnich i ujemnych dla celów implantacji jonowej.
first rewind previous Strona / 1 next fast forward last