Examples of automation of technological processes for mineral extraction are presented. Aspects related to the diagnostics of machines and devices during operation processes are discussed. Applying the distributed sensor networks to enable designing and manufacturing the machines and devices operated in accordance with the idea of Industry 4.0, the Internet of Things, M2M communication and autonomous behaviour was proposed. The paper presents impact of applying the distributed sensor networks on increasing work safety (multi-redundant communication) and reducing the employment in hazardous areas is presented. Implementation of algorithms based on swarm intelligence to control the routing processes of distributed sensor networks was suggested. Areas of application of distributed sensor networks based on swarm intelligence in other industries (renewable energy sources) are also outlined.
EN
In order to improve the efficiency and ensure the security of power supply used in a mine, this paper mainly studies the quasi-resonant flyback secondary power supply and analyzes its operational principles based on the requirements of soft-switching technology. In accordance with the maximum energy of a short-circuit and the request of maximum output voltage ripple, this paper calculates the spectrum value of the output filter capacitor and provides its design and procedures to determine the parameters of the main circuit of power supply. The correctness and availability of this theory are eventually validated by experiments.
3
Content available remote Zastosowanie praktyczne izolatorów cyfrowych w aplikacjach iskrobezpiecznych
PL
W artykule są przedstawione wyniki badań oraz określono możliwości, interpretacje, uwagi praktyczne projektowania obwodów separacji galwanicznej z zastosowaniem nowoczesnych izolatorów cyfrowych w aplikacjach iskrobezpiecznych.
EN
The article presents the results of research, interpretations, practical considerations on design of galvanic separation circuits using modern digital isolators in intrinsically safe applications. Practical limitations, related to use of iCoupler® and ISO technology digital isolators in intrinsically safe applications, were defined.
PL
Artykuł przedstawia formalne aspekty dotyczące projektowania urządzeń, których budowa przeciwwybuchowa osiągana jest poprzez iskrobezpieczeństwo. Szczegółowo zostały rozważone zagadnienia związane z temperaturą elementów i powierzchni. Przedstawione zostały stawiane w tym zakresie wymagania oraz środki i sposoby ich spełnienia przewidziane przez normy i dyrektywy.
EN
The article presents formal aspects of designing intrinsically safe explosion-proof apparatus, with main focus on requirements towards temperatures of elements and surfaces. Formal requirements as stated by normative documents, as well as means of fulfilling them and possible pitfalls, are addressed.
PL
Badanie ogniw/akumulatorów jest jednym z kluczowych procesów dotyczących urządzeń w wykonaniu przeciwwybuchowym. Na ich podstawie dokonuje się oceny warunków i możliwości ich zastosowania. Bada się skłonność ogniw do gazowania i wycieku elektrolitu w trakcie zwarcia wewnętrznego, mierzy maksymalny prąd zwarcia i maksymalną temperaturę na powierzchni. W artykule przedstawiono trudności związane z prawidłowym prowadzeniem badań oraz wpływ konstrukcji stanowiska na wiarygodność uzyskanych wyników badań.
EN
Test cell/battery is one of the key processes relating to explosion-proof equipment. On this basis, we assess the conditions and possibilities of their use. It is examine the tendency of cells to gassing and leakage during inside short circuit, measures the maximum current and maximum temperature on the surface. The article shows the difficulties inherent to the correct conduct of the research and the impact of the test-stand construction on the credibility of the results obtained.
PL
W artykule opisano system sterowania KOGASTER w konfiguracji przeznaczonej do górniczych maszyn z napędem spalinowym. Sprecyzowano wymagania jakie muszą spełniać instalacje elektryczne napędów spalinowych. Opisano podzespoły systemu KOGASTER realizujące funkcje sterujące, w tym najnowszy komponent - modułowy zasilacz z podtrzymaniem akumulatorowym i magistralą komunikacyjną. Przedstawiono połączenie modułów systemu KOGASTER dedykowane do sterowania napędem spalinowym w mobilnej maszynie górniczej.
EN
KOGASTER control system arranged for mining machines with diesel engine is presented. Requirements for electrical installations of diesel engines are specified. KOGASTER system subassemblies used for controlling purpose, including the latest component - modular power supply with battery backup and CAN system are described. Connections of the KOGASTER system modules intended for controlling the diesel engine in mobile mining machines are given.
PL
W artykule przedstawione zostało rozwiązanie iskrobezpiecznego multimetru dla górnictwa. Opisywane rozwiązanie umożliwia pracę diagnostyczną (może służyć do wczesnej diagnostyki przedusterkowej) w warunkach zagrożenia wybuchem metanu lub pyłu węglowego, służy zatem do pomiaru dopuszczalnych w tym środowisku wielkości elektrycznych. Urządzenie charakteryzuje się niewielkimi gabarytami, uchwytem magnetycznym, jest sterowane jednym przyciskiem, co znacząco zwiększa ergonomię obsługi przyrządu. Dzięki zastosowanemu wyświetlaczowi LED może być w wygodny sposób użytkowane w nieoświetlonych miejscach pracy. W fazę projektowania urządzenia zaangażowane są osoby wykorzystujące tego rodzaju przyrządy na co dzień.
EN
The article presents the solution of intrinsically safe multimeter for mining. The described solution enables diagnostic work (which can be used for early prefault diagnostics) in potentially explosive atmospheres of methane or coal dust, and therefore serves to measure permissible in this environment electrical values. The device is characterized by its small dimensions, magnetic catcher, one-button control, which significantly increases the ergonomics of the instrument. Use of LED display, enables comfortable use of instrument in low-light locations. People using such devices on a daily basis are engaged in design phase of the device.
PL
Badanie ogniw/akumulatorów jest jednym z kluczowych procesów dotyczących urządzeń w wykonaniu przeciwwybuchowym. Na ich podstawie dokonuje się oceny warunków i możliwości ich zastosowania. Bada się skłonność ogniw do gazowania i wycieku elektrolitu w trakcie zwarcia wewnętrznego, mierzy maksymalny prąd zwarcia i maksymalną temperaturę na powierzchni. W artykule przedstawiono trudności związane z prawidłowym prowadzeniem badań oraz wpływ konstrukcji stanowiska na wiarygodność uzyskanych wyników badań.
EN
Test cell/battery is one of the key processes relating to explosion-proof equipment. On this basis, we assess the conditions and possibilities of their use. It is examine the tendency of cells to gassing and leakage during inside short circuit, measures the maximum current and maximum temperature on the surface. The article shows the difficulties inherent to the correct conduct of the research and the impact of the test-stand construction on the credibility of the results obtained.
9
Content available Galvanic separation – selected aspects of ATEX
EN
The paper systematizes basic information on galvanic separation, describes reasons for its application and presents methods how to conduct it. The authors mentioned selected issues related to galvanic separation in intrinsically safe automatic devices and systems. They also described the requirements of the PN-EN 60079-11 regarding measures that ensure intrinsic safety of particular galvanic separation solutions as well as their impact on proper functioning of separation systems. The paper features the possibilities to limit parameter values of separation systems. These possibilities result from the application of intrinsic-safety measures [2].
PL
Artykuł systematyzuje podstawowe informacje dotyczące separacji galwanicznej, opisuje przyczyny jej stosowania oraz sposoby realizacji. W artykule poruszone zostały wybrane zagadnienia związane z separacją galwaniczną w iskrobezpiecznych urządzeniach i systemach automatyki. Opisano wymagane normą PN-EN 60079-11 środki zapewniające iskrobezpieczeństwo poszczególnych rozwiązań separacji galwanicznej oraz wpływ stosowania tych środków na właściwości funkcjonalne układów separacji. Przedstawione zostały możliwości ograniczenia wartości parametrów układów separacji wynikające ze stosowania środków zapewniających iskrobezpieczeństwo [2].
EN
The article features the EMC(electromagnetic compatibility) requirements concerning resistance of power protection devices with intrinsically safe circuits. The most important standards and recommendations were presented for the construction of electronic devices for industrial automation systems.
PL
W artykule przedstawiono wymagania kompatybilności elektromagnetycznej EMC dotyczące odporności dla urządzeń elektroenergetycznej automatyki zabezpieczeniowej EAZ z obwodami iskrobezpiecznymi. Podano najważniejsze normy oraz zalecenia regulujące konstruowanie urządzeń elektronicznych dla automatyki przemysłowej.
PL
W pracy omówiono możliwość zwiększenia wartości energii elektrycznej przesyłanej na odległość w sposób iskrobezpieczny z wykorzystaniem metalowego toru do zasilania urządzeń elektronicznych ulokowanych w strefach zagrożonych wybuchem gazów i aerozoli palnych. W torze współosiowym zwiększenie dopuszczalnej wartości natężenia prądu może być zrealizowane za pomocą wykorzystania przewodu centralnego wykonanego jako skrętka z kilku cienkich przewodów odizolowanych od siebie elektrycznie (przewód typu lica). Pozwala to zmniejszyć indukcyjność wewnętrzną toru współosiowego i tym samym możliwość zwiększenia iskrobezpiecznej wartości natężenia prądu w obwodzie zdalnego zasilania.
EN
The paper presents the possibility of increasing the amount of electric energy sent via an intrinsically safe metal circuit for supply of power electronic devices located in hazardous areas where the firedamp may occur. The factors deciding on the amount of the intrinsically safe electric energy transmitted over a distance are: loss of energy associated with the resistance of the circuit tracks, energy accumulated in reactance elements and the time delay caused by them. To minimize the energy loss, it seems to be a good solution to use a relatively high input voltage, but due to safety against electric shock only voltages up to 60 VDC can be taken under consideration. The transmission path represents a linear, passive electric cell with distributed parameters, which makes it a delay circuit whose time of delay is associated with its inductance and capacitance. The mentioned circuit delay affects the time of response of the safety circuit (with for ex. “foldback” type of protection) which ensures the intrinsic safety of the transmission path using the preemptive energy isolation at the moment of emergency commutation which may occur in any point of the circuit. In the paper there is stated that the coaxial cable permissible amount of energy can be increased within the usage of the central path made as the twisted pairs of multiple cords isolated electrically one from another (wire type “lica”). It allows decreasing the internal inductance of the coaxial path which enables the increase in the intrinsically safe current in the remote power supply circuit which also drops the response time of the safety barrier down.
PL
W artykule przedstawiono wymagania dotyczące elektrycznych urządzeń kontrolno-pomiarowych stosowane w przestrzeniach zagrożenia wybuchem. Ze względu na specyficzne warunki pracy muszą spełniać, oprócz stawianych im wymagań eksploatacyjnych, wymagania dotyczące iskrobezpieczeństwa. Zastosowanie tych urządzeń w przestrzeniach zagrożenia wybuchem, wymaga od nich specjalnej konstrukcji zapewniającej maksymalne bezpieczeństwo pracy.
EN
The article presents the requirements for electrical for measurement and control equipment used in explosion hazard areas. Due to the specific working conditions must meet, in addition their requirements for performance, the requirements for intrinsic safety. The use of these devices in explosion hazard areas, requires them to special design for maximum safety.
PL
W artykule przedstawiono wymagania, którym podlegają urządzenia towarzyszące stosowane w górnictwie oraz zaprezentowano stosowane układy pomiarowe z izolacją, pozwalające spełnić te wymagania. Zaproponowano rozwiązanie układu pomiarowego z izolacją wykorzystujące transoptor liniowy.
EN
The paper presents the requirements for associated apparatus used in the mining industry. Isolated measurement circuits diagrams conforming to presented requirements was presented. Measurement circuit diagram isolated using linear optocoupler was proposed.
PL
W artykule przedstawiono metody pomiarowe stosowane w celu identyfikacji i lokalizacji uszkodzeń kabli i przewodów elektroenergetycznych. Wybrano i omówiono metodę spełniającą wymagania iskrobezpieczeństwa do zastosowania w podziemnych sieciach górniczych Zaprezentowano również aparaturę pomiarową skojarzoną z tą metodą pomiarową.
EN
The article presents methods of measurement used for identification and localization to power cables damages. Selected and discussed in detail the method that meets requirements intronic safety for use in underground mining and electricity networks presented also measuring equipment associated with this measurement method.
PL
Obwody kontroli ciągłości uziemienia iskrobezpiecznego wymagają dużej liczby pomiarów kontrolujących wartości poszczególnych elementów układu. Artykuł prezentuje nowatorskie rozwiązanie takiego obwodu pomiarowego, pozwalające znacznie uprościć proces i skrócić czas kalibracji całego urządzenia.
EN
Intrinsically safe earthing continuity control circuits require a large number of measurements that inspect the various elements of the circuit. The paper presents an innovative solution of intrinsically safe earthing continuity control circuit, allowing greatly simplify and speed up whole unit calibration process.
PL
Artykuł prezentuje wymagania stawiane współczesnym górniczym sterownikom polowym, które podlegają dyrektywie ATEX. Przedstawiono sprawdzoną architekturę urządzeń zabezpieczeniowych stosowaną w rozwiązaniach dla górnictwa.
EN
The article presents the requirements for mining protection relay conforming to ATEX directive. The paper presents the architecture of the applied protection devices used in the mining industry.
PL
W artykule przedstawiono konstrukcję iskrobezpiecznego kontrolera wejść/wyjść współpracującego z magistralą przemysłową Profibus DP. Urządzenie steruje rozdzielaczami elektropneumatycznymi w podziemiach kopalń. Wykorzystano w tym celu następujące układy: LSPM 2 (Siemens), mikrokontroler PIC18F872 (Microchip), CPLD XCR3128XL (Xilinx). Do komunikacji z magistralą Profibus DP służą porty optyczne oraz port RS-485. Celem pracy było zbudowanie taniego urządzenia iskrobezpiecznego, pełniącego rolę kontrolera wejść/wyjść, będącego częścią zespołu iskrobezpiecznych rozdzielaczy elektropneumatycznych.
EN
This paper presents the design of a intrinsically safe I/O module controller works with industrial Profibus DP bus. The device controls the electropneumatic distributors in underground mines. Used for this purpose systems include: LSPM 2 (Siemens), PIC18F872 microcontroller (Microchip) and XCR3128XL CPLD (Xilinx). To communicate with the Profibus DP bus are used optical ports and port RS-485. The aim of this study was to build as cheap as possible intrinsically safe device that acts as the I/O controller, which is part of the team intrinsically safe electro-valves.
PL
Systemy i urządzenia iskrobezpieczne muszą spełniać odpowiednie wymagania kompatybilności elektromagnetycznęj (EMC). Jednoczesne zapewnienie iskrobezpieczeństwa oraz kompatybilności elektromagnetycznej sprawia często wiele trudności i pociąga za sobą konieczność realizowania nieraz sprzecznych ze sobą zaleceń. Możliwości stosowania powszechnie znanych i dostępnych środków czy rozwiązań pozwalających spełnić warunki EMC w urządzeniach i systemach iskrobezpiecznych są przeważnie znacznie ograniczone. Niektóre rozwiązania są jednak korzystne zarówno dla uzyskania iskrobezpieczeństwa, jak też dla zapewnienia kompatybilności elektromagnetycznej. W artykule opisano odniesienie do szeregu wymogów i ograniczeń narzucanych projektantowi urządzeń przeznaczonych do pracy w atmosferach wybuchowych przez normy przedmiotowe zgodne z dyrektywami 94/9/WE: ATEX [1] i 2004/108/WE: EMC [2]. Omówiono wybrane problemy występujące w urządzeniach iskrobezpiecznych przy spełnianiu wymagań norm zharmonizowanych dyrektywą EMC.
EN
The article features some issues related to the requirements and limitations imposed on the developers of devices working in explosive atmospheres by standards compliant with the directives 94/9/EC: ATEX [1] and 2004/108/EC: EMC [2]. The authors discussed selected problems occurring in intrinsically safe devices that are compliant with standards harmonized with the EMC directive.
PL
W artykule omówiono zakres stosowania i skuteczność zapewnienia iskrobezpieczeństwa obwodów elektrycznych za pomocą układów ochronnych z liniową i nieliniową charakterystyką prądowo-napięciową. Pokazano, że drogą stosowania układów ochronnych z nieliniową charakterystyką prądowo-napięciową można dostarczyć kilkakrotnie większą iskrobezpieczną moc do odbiorników energii elektrycznej w stosunku do liniowych układów ochronnych. Perspektywicznym kierunkiem w rozwoju układów ochronnych z nielniową charakterystyką prądowo-napięciową są układy ochronne z wykorzystaniem generatorów samowzbudnych. Pozwala to na realizację układu ochronnego czułego na dodatnie i ujemne zmiany wartości prądu oraz wyprzedzającej separacji obwodu chronionego od źródła zasilania przed powstaniem wyładowania elektrycznego w punkcie komutacji awaryjnej. Przy tym odpada konieczność redundancji elementów sterowanych. Zapewnia się możliwość stosowania tranzystorów jako elementów sterowanych dla zapewnienia poziomu iskrobezpieczeństwa "ia".
EN
The article features the range and efficiency of providing intrinsically safe qualities to electric circuits with the use of protection systems with linear and non-linear current and voltage characteristics. It was demonstrated that by means of protection systems with non-linear current and voltage characteristics it is possible to provide several times more intrinsically safe power to electric energy receivers than in the case of linear protection systems. The development of protection systems with non-linear current and voltage characteristics is directed towards protection systems with self-exciting generators. This allows to have a protection system sensitive to positive and negative changes of current value, along with ancestor separation of the protected system from the power supply source before an electric discharge occurs at the emergency commutation point. Here, it is not necessary to provide redundancy of controlled elements. It is possible to use transistors as controlled elements to provide the "ia" level of intrinsic safety.
PL
W referacie zwrócono uwagę na systemy łączności z wykorzystujące specjalnie instalowane tory przewodowe (wraz ze wzmacniaczami aktywnymi) dla propagacji kierunkowej fal elektromagnetycznych w wyrobiskach. Omówiono problem iskrobezpieczeństwa systemu radiokomunikacyjnego, wykorzystującego przewód promieniujący. Przedstawiono sposób podejścia do tego zagadnienia dla przykładowej struktury takiego systemu eksploatowanego w kopalni metanowej. O iskrobezpieczeństwie całego systemu decydują przede wszystkim parametry zasilacza iskrobezpiecznego zastosowanego dla zasilania wzmacniaczy liniowych systemu telekomunikacyjnego.
EN
There has been paid attention in the paper to communication systems using specially installed cable circuits (including active amplifiers) for directional electromagnetic wave propagation in mine workings. The problem of intrinsic safety of a radio-communication system using a radiating cable has been discussed. A manner of approach to this problem has been presented for an example of such system which operates in a methane mine. The parameters of an intrinsically safe supply unit for line amplifiers of the telecommunication system decide mainly about intrinsic safety of the whole system.
first rewind previous Strona / 2 next fast forward last