The problem of voltage collapse is a major issue in the operation of the current power system, especially when the penetration of wind turbines into the system continues to increase. The intermittency of the wind turbine has an impact on the stability of the system voltage. Fast Voltage Stability Index (FVSI) is used as a parameter for the condition of the system with the phenomenon of voltage collapse. This study aims to observe and predict the value of the Line stability index using Optimally Pruned Extreme Learning Machine (OP-ELM). The test case in this study is the South Sulawesi-Indonesia Electric Power System, with a total wind turbine penetration of 142 MW. From the simulation, it can be seen that OPELM can do forecasting very well with an error rate of 0.0886%.
PL
Problem załamania napięcia jest poważnym problemem w funkcjonowaniu obecnego systemu elektroenergetycznego, zwłaszcza gdy penetracja turbin wiatrowych do systemu nadal wzrasta. Przerywalność turbiny wiatrowej ma wpływ na stabilność napięcia systemu. Wskaźnik stabilności szybkiego napięcia (FVSI) jest używany jako parametr stanu systemu ze zjawiskiem załamania napięcia. Niniejsze badanie ma na celu obserwowanie i przewidywanie wartości wskaźnika stabilności linii przy użyciu maszyny OP-ELM (ang. Optimally Pruned Extreme Learning Machine). Przykładem testowym w tym badaniu jest system elektroenergetyczny South Sulawesi-Indonesia, z całkowitą penetracją turbin wiatrowych 142 MW. Z symulacji widać, że OP-ELM może bardzo dobrze wykonywać prognozy ze wskaźnikiem błędu 0,0886%.
Solar irradiation is characterized by a significant variability on a time scale. Thereby the source of electric energy based on photovoltaic effects becomes unstable. As a result there may appear periods when amount of energy generated from PV is insufficient to cover energy needs of scheduled activities. In a case of time series with a relatively high value of a coefficient of variation (CV) which fluctuations cannot be explained by known in advance exogenous variables one may apply artificial neural networks. In this paper values of hourly solar irradiation have been forecasted for five and fifteen minutes ahead based on solar irradiation level from former periods and located nearby hypothetical measuring stations. The obtained results are promising.
PL
Promieniowanie słoneczne cechuje się znaczną zmiennością w czasie. Tym samym źródła energii elektrycznej, wykorzystujące zjawisko efektu fotowoltaicznego stają się niestabilne. W rezultacie mogą występować okresy gdy ilość wuprodukowanej energii z instalacji PV jest niewystarczająca do pokrycia bieżącego zapotrzebowania. W wypadku szeregów czasowych cechujących się wysoką wartością współczynnika zmienności (CV), których wahania nie mogą być wujaśnione przez wcześniej znane zmienne egzogeniczne, rozwiązaniem staje się zastosowania sztucznych sieci neuronowych. W tym artykule zaprezentowane zostało prognozwania wartości nasłonecznienie z pięcio oraz piętnastominutowym horyzontem czasowym, w oparciu o dane pochodzące z teoretycznych stacji pomiarowych znajdujących się w określonej odległości od badanej instalacji PV. Uzyskane wyniki są obiecujące.
Przedstawiono wpływ aktywnego powierzchniowo polimeru PVA o stopniu hydrolizy 88% i masie cząsteczkowej 85000-124000 na rozpad i koalescencję kropel w dyspersji toluen-woda mieszanej mechanicznie. Zwiększenie częstości obrotów mieszadła i stężenia polimeru spowodowało zmniejszenie wielkości kropel oraz zwiększenie powierzchni międzyfazowej. Doświadczalne rozkłady wielkości kropel zostały poprawnie przewidziane przez model multifraktalny, który użyto do opisu rozpadu kropel w równaniu bilansu populacji.
EN
The influence of surface active polymer PVA of the hydrolysis degree equal to 88% and molecular weight 85 000-124 000 on drop breakage and coalescence in agitated toluene − water dispersion was presented. Increased impeller rotational speed and polymer concentration caused the drop size reduction and interfacial area increase. Experimental drop size distributions were correctly predicted by the multifractal model used to describe drop breakage in the population balance equation.
Przedstawiono wpływ surfaktantu niejonowego Tweenu 80 na rozpad i koalescencję kropel. Zaobserwowano dodatkowe naprężenia rozrywające wynikające z różnicy między międzyfazowym napięciem równowagowym (dla t → ∞) i napięciem dynamicznym (dla t → 0), które zwiększają szybkość rozpadu kropel. Dla c = 0,0012 mM powierzchnie kropel pozostają częściowo ruchliwe. Natomiast dla c > 0,0012 mM koalescencja kropel jest znacznie utrudniona, dzięki czemu może być pominięta w równaniu bilansu populacji.
EN
The influence of surface active agent Tween 80 on drop breakage and coalescence is shown. Additional disruptive stresses connected with the difference between interfacial equilibrium tension (for t → ∞) and dynamic tension (for t → 0 ), and responsible for the increase of drop breakage rate were observed. For c = 0.0012 mM drop surfaces remain partially mobile, whereas for c > 0.0012 mM drop coalescence is significantly hampered. Therefore, it can be omitted in the population balance equation.
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The paper presents validation of -Reθ model proposed by Menter at al (2006), which was extended by in-house correlations on onset location and transition length. The tests performed were based on experimental data on the flat plate test cases where l-t transition, laminar separation and reattachment were present. The model was applied both for steady and unsteady calculations. It was shown that the model was able to reproduce some essential flow features related to the separated transition and the simulations reveal good agreement with the experimental results.
6
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The paper presents a review of the current knowledge concerning the modelling of laminar – turbulent transition on turbomachinery blading. The most important physical features of laminar – turbulent transition are reviewed and their consequences for CFD modelling are discussed. The main features and assumptions of existing models are discussed with special reference to intemittency based models. The limitations of existing models are discussed and the reasons why intermittency – based models seem to be a promising perspective are outlined. The main features of intermittency – based model developed at the Institute of Thermal Machinery and extended by in-house correlations on onset location and transition length are also presented and discussed.
7
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
In the paper four models of drop breakage in turbulent flow were compared. Breakage models were included to the population balance equation to predict transient drop size distributions. Predicted distributions were compared with experimental data. It was shown that models that take into account the effect of the system scale on breakage (multifractal model and model based on the division of impeller region into isotropic turbulent region and nonisotropic turbulent region) predict drop sizes most properly.
PL
W artykule porównano cztery modele rozpadu kropel w polu burzliwym. Modele rozpadu zostały włączone do równania bilansu populacji w celu przewidywania zmian rozkładów wielkości kropel w czasie. Obliczone rozkłady zostały porównane z rozkładami zmierzonymi. Pokazano, że modele uwzględniające wpływ skali układu na rozpad kropel (model multifraktalny i model oparty na podziale strefy mieszadła na strefy burzliwości izotropowej i nieizotropowej) dają najlepsze rezultaty. Model oparty na podziale stref zawiera jednak aż cztery stałe, które muszą być dobierane dla każdego układu. Stosunkowo dobrze rozmiary kropel mogą być również przewidziane za pomocą modelu Coulaloglou i Tavlaridesa. Model Martineza-Bazan przewiduje krople o rząd wielkości za duże.
8
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The sediment transport process on a flat bed was investigated experimentally, with reference to the relationship between the average solid discharge and the concentration and velocity of the moving grains. The instantaneous values of the quantities were measured and, therefore, it was possible to quantify the contribution of the temporal fluctuations of concentration and velocity to the resulting average sediment transport rate. Recognizing that the sediment transport process is an episodic phenomenon, an intermittency factor was defined and its contribution to the solid discharge, typically implicit in earlier formulations of the sediment flux, was highlighted. Conceptual analyses of the spatial scale dependence of the quantities were also made.
The paper shows the results of calculations obtained with the use of intermittency transport model (ITM). The model is based on two transport equations, one for the intermittency (gamma) and the other for the momentum thickness Reynolds number (Re theta t). To trigger transition onset and length of transition in-house correlations were used.
PL
Przedstawiono wyniki obliczeń wykonanych z użyciem modelu transportu intermitencji (ITM). Zaproponowany model oparto na dwóch dodatkowych równaniach transportu: intermitencji (gamma) oraz liczby Reynoldsa opartej na mierze liniowej straty pędu (Re theta t). W celu właściwej identyfikacji strefy przejścia zaproponowano własne zależności na lokalizację początku, oraz długości przejścia l-t.
W pracy przedstawione zostały wyniki obliczeń współczynnika intermitencji y w oparciu o dane eksperymentalne zarejestrowane w warstwie przyściennej na profilu turbinowym, zaburzonej śladami spływowymi. Rozkłady y zostały uzyskane w oparciu o sygnały prędkościowe przetworzone zgodnie z procedurą zaproponowaną w Instytucie Maszyn Cieplnych Politechniki Częstochowskiej. W artykule wykazano różnicę w obszarach oddziaływania śladów spływowych oraz w obszarach pomiędzy śladami.
EN
The paper presents the results of intermittency factor y calculations based on the experimental data recorded in the boundary layer on the turbine blade, which is disturbed by incoming wakes. The intermittency factor distributions was obtained based on the velocity signals processed according to procedure developed at Institute of Thermal Machinery at Czestochowa University of Technology. In the paper the differences in the regions under the wakes and in between the wakes were pointed out.
The problem of internal intermittency in fully developed hydrodynamic turbulence is considered. A relatively simple phenomenological model for the energy-cascading process in the inertial range is proposed. The model is a combination of two models: the β-model and the log-stable distribution intermittency model. Results are in excellent agreement with experimental data when the intermittency exponent is μ = 0.17 (calculated) and the characteristic exponent of the distribution is α = 1.9 (free parameter, obtained by the least-squares method).
PL
W pracy rozważono zagadnienie wewnętrznej intermittencji rozwiniętego przepływu turbulentnego. Zaproponowano prosty, fenomenologiczny model procesu przenoszenia energii w przepływie przez kaskadę wirów, będący połączeniem tzw. β-modelu i logarytmicznie stabilnego modelu intermittencji. Uzyskano bardzo dobrą zgodność z istniejącymi danymi eksperymentalnymi przy wyborze wykładnika intermittencji μ = 0,17 (na podstawie obliczeń) i wykładnika charakterystycznego rozkładu α = 1,9 (metodą najmniejszych kwadratów).
W pracy przedstawiono i przedyskutowano metody powiększenia skali zbiorników z mieszadłem stosowane celem zapewnienia zbliżonych rozkładów wielkości kropel i agregatów cząstek ciała stałego w układach dyspersyjnych ciecz-ciecz i ciecz-ciało stałe. Przedyskutowano metody powiększenia skali wykorzystując klasyczną teorię burzliwości Kołmogorowa oraz teorię burzliwości uwzględniającą zjawisko intermittencji wewnętrznej (model multifraktalny przepływu burzliwego).
EN
A multifractal model of turbulence is used to predict the size of drops and aggregates and to interprete some popular methods for scaling up. New scaling method are considered as well.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.