Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  interferencje spektralne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A systematic study on the efficiency of inductively coupled plasma quadruple mass spec-trometry (1CP-QMS) in determination of stable mercury isotopes profile has been conducted. Two types of effects have been observed: non-specific, which influenced all mercury isotopes, and specific, which applied only to selected isotopes. Non-specific effects were those, for which the sensitivity depended significantly on the type of mercury compound present in the solution: sensitivity decreased almost 2 and 3 times for chloride and pheny Imercury PhHg+ ions, respectively, compared to that for mercury in the form of inorganic Hg2+ as a nitrate(V). The influence of platinum and lead was specific for isotopes exposed to isobaric spectral interferences, which meant that determination of the following isotopes: 199Hg, 200Hg, 201Hg and 202Hg was unaffected. In case of l%Hg, 198Hg and 204Hg significant isobaric interferences from 196198204
PL
W pracy przedstawiono wyniki badań dotyczących możliwości oznaczania stabilnych izotopów rtęci techniką kwadrupolowej spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP—QMS). Zaobsserwowano dwa rodzaje interferencji: niespecyficzne, wpływające w równomierny sposób na wszystkie oznaczane izotopy, oraz specyficzne, wpływające na wybrane izotopy. Efekty niespecyficzne są związane z formą chemiczną, w jakiej rtęć występuje w roztworze. W porównaniu do czułości oznaczania rtęci występującej w formie nieorganicznej (Hg2+) w postaci azotanow(V), czułość oznaczania zmniejsza się odpowiednio dwu- lub trzykrotnie dla chlorku rtęci(II) i octanu fenylo rtęci.
EN
The effect of digestion of road dust in the mixture of aqua regia + HF and of the leaching of the analytes with aqua regia only on the determination of Pt and Pd applying ICP-MS technique has been investigated. In order to eliminate spectral interferences in mass spec-trometry. mathematical correction was applied, as well as the interferents were separated from the analytes on a Dowex 50 WX-8 cation-exchange resin. It has been, found that after addition of HF, Hf and Y are transformed into stable fluoride compounds, which are not retained on the cation-exchanger and cause some interferences in the determination step. Leaching of the analytes with aqua regia without complete sample dissolution resulted in the release of Pt and Pd from the road dust. Noteworthy, the analytes were present in the sample in the form suitable for their separation on cation exchanger. The correctness of the applied procedure was confirmed via analysis of certified reference material BCR-723.
PL
Zbadano wpływ sposobu rozkładu próbek pyłu drogowego na oznaczanie Pt i Pd metodą spektrometrii mas z jonizacją w plazmie indukcyjnie sprzężonej (ICP-MS). W celu wyeliminowania interferencji spektralnych zastosowano metodę korekcji matematycznej w spektrometrii mas oraz oddzielanie analitów od pierwiastków inter ferujących (Hf, Y) na kationicie Dowex 50 WX-8. Stwierdzono, że zastosowanie do mineralizacji HF powoduje tworzenie się trwałych połączeń fluorkowych Hf i Y, które nie zatrzymywane na kationicie są przyczyną interferencji w etapie oznaczania. Ługowanie analitów wodą królewską zapewnia ilościowe uwolnienie Pt i Pd z pyłu drogowego, jak również występowanie analitów i pierwiastków interferujących w formie odpowiedniej do ich rozdzielania na kationicie. Poprawność proponowanej procedury potwierdzono analizując certyfikowany materiał referencyjny BCR-723.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.