Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  interference suppression
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Ever rising increase in number of wireless services has prompted the use of spatial multiplexing through null steering. Various algorithms provide electronic control of antenna array pattern. Simulation-driven technique further introduces correction in array factor to account for array geometry. Taguchi method is used here to combat interference in practical antenna arrays of non-isotropic elements, by incorporating the effect of antenna element pattern on array pattern control in the optimization algorithm. 4-element rectangular and bowtie patch antenna arrays are considered to validate the effectiveness of Taguchi optimization. The difference in the computed excitations and accuracy of null steering confirms the dependence of beam pattern on element factor and hence eliminates the need for extra computations performed by conventional algorithms based on array factor correction. Taguchi method employs an orthogonal array and converges rapidly to the desired radiation pattern in 25 iterations, thus signifying it to be computationally cost-effective. A higher gain and a significant reduction in side lobe level (SLL) was obtained for the bowtie array. Further, due to feed along parallel edges of the patch, the radiating edges being slanted to form the bow shape results in a significant reduction in the area as compared with the rectangular patch designed to resonate at the same frequency.
2
PL
Podstawowy obszar aplikacyjny termoanemometrów stanowią pomiary fluktuacji prędkości przepływu gazów w szerokim spektrum częstotliwości. Istotną cechą termoanemometrycznych systemów pomiarowych jest więc możliwie duże pasmo przenoszenia sygnału pomiarowego. Standardowo szerokie pasmo przenoszenia uzyskuje się poprzez zastosowanie stałotemperaturowego trybu pracy anemometru. W trybie tym temperatura grzanego elementu pomiarowego utrzymywana jest na stałym poziomie dzięki zastosowaniu układu elektronicznego ze sprzężeniem zwrotnym. Pasmo przenoszenia dla termoanemometrów stałotemperaturowych może sięgać setek kiloherców. Ponieważ czujnik termoanemometryczny stanowi pod względem elektrycznym rodzaj pętli indukcyjnej, mogą indukować się w nim zakłócenia elektromagnetyczne. Duże wzmocnienie oraz szerokie pasmo przenoszenia układu stałotemperaturowego powodują, że w przypadku występowania zakłóceń elektromagnetycznych udział sygnałów niepożądanych w sygnale wyjściowym termoanemometru może być znaczący. W pracy tej przedstawiono koncepcję metody eliminacji tych zakłóceń.
EN
The main application area for hot-wire anemometers are measurements of gas flow velocity fluctuations in a wide range frequency spectrum. An important feature of hot-wire anemometric measuring systems is therefore the highest possible frequency bandwidth of the measuring circuit. As a standard, a wide frequency response is obtained by using a constant temperature mode of the anemometer. In this mode, the temperature of the heated measuring element is kept constant, by the use of an electronic system with feedback. The frequency response for constant temperature anemometers can reach hundreds of kilohertz. Since the hot-wire sensor is a kind of induction loop in electrical terms, electromagnetic interference may be induced in it. The high gain and the wide frequency bandwidth of the constant temperature system mean that in the event of electromagnetic interference, the share of unwanted signals in the output signal of the anemometer can be significant. This work presents the concept of the method for eliminating these disturbances.
EN
The overlap between the signal components of Power Line Interference (PLI) and biomedical signals in the frequency domain makes the filtered results prone to severe distortion. Electrocardiogram (ECG) is a type of biomedical electronic signal used for cardiac diagnosis. The objective of this work is to suppress the PLI components from biomedical signals with minimal distortion, and the object of study is mainly the ECG signals. In this study, we propose a novel segment-wise reconstruction method to suppress the PLI in biomedical signals based on the Bidirectional Recurrent Neural Networks with Long Short Term Memory (Bi-LSTM). Experiments are conducted on both synthetic and real signals, and quantitative comparisons are made with a traditional IIR notch filter and two state-of-the-art methods in the literature. The results show that by our method, the output Signal-to-Noise Ratio (SNR) is improved by more than 7 dB and the settling time for step response is reduced to 0.09 s on average. The results also demonstrate that our method has enough generalization ability for unforeseen signals without retraining.
PL
Pomiar wyładowań niezupełnych, jest ze względu na dużą czułość urządzeń pomiarowych, często utrudniony. Mają na to wpływ różne zakłócenia. Najbardziej narażony jest pomiar wyładowań niezupełnych w warunkach przemysłowych on-line. Źródła zakłóceń mogą być różne (pochodzące z urządzenia badanego, urządzeń znajdujących się w pobliżu lub z sieci niskiego i wysokiego napięcia, radiowe). Niektóre zakłócenia są tłumione przez zastosowanie odpowiedniej konfiguracji układu pomiarowego. Wybór sposobu tłumienia jest jednak ściśle związany z warunkami pomiaru i obiektem mierzonym.
EN
The measurement of partial discharge is often hindered due to the high sensitivity of the measuring instruments. This is influenced by a number of sources of interference which the measurement is most expose to in industry conditions on-line. The source of the interference varies (and may come from the tested device it self, any devices in the vicinity or from low or high voltage networks or radio). Some interference is suppressed by using an appropriate configuration of the measurement system. The choice of the suppression method is however strictly linked to the measurement conditions and the object measured.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.