Motivated by the superior performances of neural networks and neuro-fuzzy approaches to fault detection of a single phase induction motor, this paper studies the applicability these two approaches for detection of stator inter-turn faults in a three phase induction motor. Firstly, the paper develops an adaptive neural fuzzy inference system (ANFIS) detection strategy and then compares its performance with that of using a multi layer perceptron neural network (MLP NN) applied to stator inter-turn fault detection of a three phase induction motor. The fault location process is based on the monitoring the three phase shifts between the line current and the phase voltage of the induction machine.