Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  inter-area oscillations
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
PL
W artykule omówiono referaty przygotowane na sesję CIGRE 2022 w ramach Komitetu Studiów C2 Sterowanie i praca systemów elektroenergetycznych. Referaty i dyskusje prowadzone podczas sesji skupiały się na zagadnieniach gotowości pomieszczenia dyspozytorskiego do współczesnych wyzwań, a także na kwestiach strategii planowania operacyjnego, jej metodyce oraz narzędziach wspierających.
EN
Discussed are papers prepared for the CIGRE 2022 session as part of the Study Committee C2 System Operation and Control. Presented papers and discussions that took place during the session focused on the issues concerning preparedness of the control room for present challenges as well as on the ssues of operational planning strategy, its methodology and supporting tools.
PL
Jednym ze zjawisk występujących w europejskim systemie elektroenergetycznym (ENTSO-E CE) są nieplanowane przepływy mocy. Powodują one realne zagrożenie dla bezpieczeństwa pracy systemu oraz ograniczają zdolności wymiany handlowej. Jednym z narzędzi służących ograniczeniu tego zjawiska są coraz powszechniej stosowane w ENTSO-E przesuwniki fazowe. W szczególnie trudnych warunkach dla obrony systemu przed nadmiernymi przepływami mocy, dla zachowania integralności własnego systemu, operatorzy sieci przesyłowej mogą podjąć decyzje o wprowadzeniu zmian topologicznych skutkujących osłabieniem połączeń międzysystemowych. Szczególnym przypadkiem działań operatorskich może być podział nie na pojedynczej granicy, ale na całym ciągu granic, prowadzący w efekcie do podziału kontynentalnej części ENTSO-E na dwie części wschodnią i zachodnią. Działania takie prowadzą do ograniczenia niepożądanych przepływów, ale mogą również oddziaływać na częstotliwość i tłumienie kołysań międzyobszarowych obserwowanych w systemie. Przedstawione w artykule wyniki stanowią ocenę jakościową (pokazują trendy zmian) wpływu wyłączeń linii granicznych w KSE na wielkość tłumienia i częstotliwości kołysań międzyobszarowych ENTSO-E CE angażujących generatory KSE.
EN
Loop flows observed on continental European power system (ENTSO-E CE) impose limitations on possible market power exchange but above all cause real threat to safe power system operation. To limit this phenomena, transmission system operators (TSOs) install phase shifting transformers on tie-lines. In case this countermeasure is not available or control range of installed devices is not sufficient to limit undesired power flow to safe level, TSOs may decide to change system topology (switch off tie-lines, splitting internal system) aiming to protect internal system integrity but weakening international connections. On one hand this action leads to reduction or elimination of unscheduled power flows but also influences on frequencies and damping of inter-area oscillations. Presented in the paper results discuss qualitative changes in inter-area oscillations pattern (frequency, damping, Polish generators contribution) caused by topology changes introduced to Polish EHV grid. Due to problems with low frequency inter-area oscillations damping either deterioration of damping or lowering the frequency may be treated as potential threat to European system safety. Additional scenario analyzing deeper changes in ENTSO-E CE system: split into western and eastern part was also investigated.
EN
Development of a dynamic model covering a large power system and suitable for analyses of inter-area oscillations often requires the use of typical system component models used in transient stability analyses. This may consequence in very optimistic results, i.e. much better oscillation damping than actually recorded in the system. This was seen in the 1990s, when in the USA and Canada (Western Interconnection) weakly damped inter-area oscillations were observed, which could not be correctly reflected using standard dynamic models. The paper analyses selected system component modelling simplifications due to the use of generic models that may affect the damping of inter-area oscillations. The degree of this impact on the results is shown in a dynamic model covering the synchronously operated part of the continental Europe system.
PL
Opracowanie modelu dynamicznego, obejmującego wielki system elektroenergetyczny odpowiedni do analiz oscylacji międzyobszarowych, często wymaga wykorzystania typowych modeli elementów systemu, wykorzystywanych w analizach stanów przejściowych. Działanie takie może skutkować uzyskaniem bardzo optymistycznych wyników, tj. dużo lepszego tłumienia oscylacji niż w praktyce rejestrowane w systemie. Przekonano się o tym już w latach 90., gdy zaobserwowano słabo tłumione oscylacje międzyobszarowe w USA i Kanadzie (Western Interconnection), których nie udało się poprawnie odwzorować z wykorzystaniem standardowych modeli dynamicznych. W artykule przeanalizowano wybrane uproszczenia modelowania elementów systemu, spowodowane wykorzystaniem modeli generycznych, które mogą mieć wpływ na poziom tłumienia oscylacji międzyobszarowych. Stopień tego oddziaływania na wyniki został pokazany na modelu dynamicznym, obejmującym synchronicznie pracującą część Europy kontynentalnej.
EN
Loop flows in the European power system (ENTSO-E CE) not only limit trade capacity, but also compromise power system operational security. In order to reduce unscheduled power transfers, phase shifters are most commonly used, usually installed on tie-lines. Where these devices are not available or their control range has been exhausted, and the unscheduled power transfer is greater than the allowable, transmission grid operators, in extreme cases, to maintain the integrity of their own systems may decide to introduce topological changes resulting in interconnection weakening. Such action reduces the undesired power transfer, but at the same time it affects the frequency and the damping of inter-area oscillations in the ENTSO-E CE system. The results presented in this paper provide a qualitative assessment (show trends of changes) of the impact of the Polish NPS (National Power System) border lines’ outages on the damping and frequency, and the contribution of NPS generators to inter-area oscillations. Due to the problems with low frequency oscillation damping in ENTSO-E CE, any reduction in the damping or frequency from the initial state should be considered a potential threat to secure system operation.
PL
Obserwowane w pracy europejskiego systemu elektroenergetycznego (ENTSO-E CE) przepływy kołowe powodują nie tylko ograniczenie zdolności wymiany handlowej, ale również stwarzają realne zagrożenie dla bezpieczeństwa pracy systemu. W celu ograniczenia takich przesyłów coraz powszechniej stosowane są przesuwniki fazowe instalowane zazwyczaj na liniach granicznych. W sytuacji, gdy urządzeń tych nie ma, czy też ich zakres regulacyjny został wyczerpany, a niepożądany przesył jest większy od dopuszczalnego, operatorzy sieci przesyłowej w skrajnych przypadkach, dla zachowania integralności własnego systemu, mogą podjąć decyzje o wprowadzeniu zmian topologicznych, skutkujących osłabieniem połączeń międzysystemowych. Działanie takie prowadzi do ograniczenia niepożądanego przesyłu, ale równocześnie oddziałuje na częstotliwość i tłumienie oscylacji międzyobszarowych obserwowanych w ENTSO-E CE. Przedstawione w artykule wyniki dokonują oceny jakościowej (pokazują trendy zmian) wpływu wyłączeń linii granicznych w KSE na wielkość tłumienia i częstotliwości oraz zaangażowania generatorów KSE w oscylacjach międzyobszarowych. Ponieważ w ENTSO-E CE występują problemy z tłumieniem oscylacji niskich częstotliwości, to każde zmniejszenie tłumienia lub częstotliwości w stosunku do stanu wyjściowego należy traktować jako potencjalne zagrożenie dla bezpieczeństwa pracy.
5
Content available remote Internal interactions of UPFC multifunction controller
EN
Interactions between controllers are one of the main reasons of weakly damped oscillations in power systems. This phenomenon is mostly due to either their inadequate tuning or the lack of coordination of their action. The analysis of the problem becomes much more complicated in case of using FACTS-based multifunctional controllers. In such a situation other reasons of control interactions could appear. This paper presents an analysis of internal interactions occurring during the multifunction operation of Unified Power Flow Controller (UPFC) installed a multimachine test system. The analysis is performed using relative gain array and generalised dynamic relative gain.
PL
Interakcje regulatorów są jedną z głównych przyczyn słabo tłumionych oscylacji pojawiających się w systemie elektroenergetycznym. Zjawisko to występuje głównie w wyniku niewłaściwego doboru parametrów regulatorów lub braku koordynacji ich działania. Analiza problemu interakcji jest szczególnie złożona w przypadku wielofunkcyjnych regulatorów urządzeń FACTS. W tym przypadku również inne przyczyny mogą powodować występowanie interakcji w układzie regulacji. Artykuł przedstawia analizę wewnętrznych interakcji powstających w wyniku działania wielofunkcyjnego regulatora urządzenia UPFC w wielomaszynowym systemie elektroenergetycznym. Analiza interakcji została przeprowadzona z wykorzystaniem metody macierzy względnego wzmocnienia oraz metody uogólnionego względnego dynamicznego wzmocnienia.
EN
This paper presents the description of a multi-machine power system mathematical model, with FACTS device - such as Unified Power Flow Controller (UPFC) included. The case of an UPFC device located between two freely selected power system network nodes is analysed. An admittance transfer matrix, composed of UPFC ratio-dependent polynomials has been created. Basing on the linearised model an evaluation of the influence of the UPFC device on electromechanical power swing damping has been conducted. To this end, the power system transfer function characteristics have been analysed in detail. Finally, a few examples of three-machine power system test results are presented.
PL
W artykule przedstawiono opis modelu wielomaszynowego systemu elektroenergetycznego zawierającego urządzenie FACTS typu UPFC. Rozważono przypadek, w którym urządzenie UPFC może być włączone pomiędzy dwa dowolne węzły sieciowe. W sposób szczegółowy omówiono sposób tworzenia admitancyjnej macierzy transferowej oraz opis jej elementów w postaci wielomianów zależnych od przekładni elementu UPFC. W oparciu o nieliniowy model rozważanego układu wyprowadzono model liniowy. Na podstawie opracowanego modelu liniowego dokonano oceny możliwości oddziaływania UPFC na tłumienie kołysań elektromechanicznych. Wykorzystano w tym celu analizę charakterystyk częstotliwościowych transmitancji systemu. Przedstawiono przykładowe wyniki badań w przypadku trójmaszynowego systemu elektroenergetycznego.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.