Content available remote Impact of ambient temperature on the failure intensity of overhead MV power lines
EN
The article presents the influence of weather conditions, represented by the ambient temperature, for the intensity of the failure of MV overhead power lines. It presents the mechanisms of damaging the equipment by the high and low temperatures. It shows the method of determining the intensity of failure of power facilities as a function of ambient temperature. The article presents the empirical results obtained for the MV overhead power lines exploited in the Polish electricity grids.
PL
W artykule przedstawiono wpływ warunków atmosferycznych reprezentowanych przez temperaturę otoczenia na intensywność uszkodzeń napowietrznych linii elektroenergetycznych SN. Zaprezentowano w nim mechanizm uszkadzania tych urządzeń na skutek oddziaływania wysokich oraz niskich temperatur. Omówiono metodę modelowania zależności intensywności awarii obiektów energetycznych od temperatury otoczenia. Zaprezentowano wyniki uzyskane podczas wieloletnich badań dla napowietrznych linii elektroenergetycznych SN eksploatowanych w polskich sieciach dystrybucyjnych energii elektrycznej.
2
Content available remote Funkcje niezawodnościowe przyłączy elektroenergetycznych nn
PL
W artykule przedstawiono wyniki oceny podstawowych funkcji określających właściwości niezawodnościowe przyłączy nn, jakimi są funkcja intensywności awarii, funkcja niezawodności oraz funkcja zawodności. Na podstawie wieloletnich obserwacji przyłączy nn eksploatowanych w sieci dużej spółki dystrybucyjnej energii elektrycznej w kraju, określono postacie empiryczne wymienionych funkcji. Przeprowadzono także analizę zgodności rozkładu empirycznego z założonym rozkładem teoretycznym. Wyznaczono wartość oczekiwaną czasu poprawnej pracy przyłączy nn do uszkodzenia. Dodatkowo określono postać funkcyjną skumulowanej intensywności uszkodzeń oraz oczekiwanego pozostałego czasu zdatności.
EN
The paper presents the results of the evaluation of basic functions determining reliability characteristics of LV connections, they are a failure intensity function, function reliability and unreliability function. Based on years of follow-up LV connections operated in large electricity distribution company in the country were defined empirical waveforms mentioned features. It was also carried out an analysis of the empirical distribution of compliance with the assumed theoretical distribution. In paper was determined the expected value of lifetime to damage of LV connections. In addition, the cumulative intensity of damage and the expected residual duration are specified.
EN
The article presents the results of the evaluation of basic functions determining reliability characteristics of LV connections, they are a failure intensity function, function reliability and unreliability function. Based on years of follow-up LV connections operated in large electricity distribution company in the country were defined empirical waveforms mentioned features. It was also carried out an analysis of the empirical distribution of compliance with the assumed theoretical distribution. In paper was determined the expected value of lifetime to damage of LV connections.
PL
W artykule przedstawiono wyniki oceny podstawowych funkcji określających właściwości niezawodnościowe przyłączy nN, jakimi są funkcja intensywności awarii, funkcja niezawodności oraz funkcja zawodności. Na podstawie wieloletnich obserwacji przyłączy nN eksploatowanych w sieci dużej spółki dystrybucyjnej energii elektrycznej w kraju, określono przebiegi empiryczne wymienionych funkcji. Przeprowadzono także analizę zgodności rozkładu empirycznego z założonym rozkładem teoretycznym. Wyznaczono wartość oczekiwaną czasu poprawnej pracy przyłączy nN do uszkodzenia.
PL
W artykule przedstawiono wyniki badań niezawodnościowych przyłączy napowietrznych i kablowych nN eksploatowanych w krajowych spółkach dystrybucyjnych. Niezależne analizy przeprowadzono dla przyłączy napowietrznych wykonanych przewodami gołymi i izolowanymi oraz dla przyłączy kablowych. Zaprezentowano statystyki awaryjności przyłączy z 10 lat pracy sieci. Przedstawiono przyczyny awarii oraz sezonową zmienność częstości uszkodzeń. Dokonano analizy czasu trwania odnowy, czasu trwania przerw w zasilaniu odbiorców oraz wartości energii elektrycznej niedostarczonej do odbiorców w wyniku awarii. Przedstawiono modele empiryczne oraz wyniki próby identyfikacji modelu teoretycznego gęstości prawdopodobieństwa rozważanych parametrów. Obliczono niezawodnościowe wskaźniki eksploatacyjne przyłączy.
EN
The paper presents the research results of reliability of overhead and cable LV connections operating in domestic distribution companies. Independent analyzes were performed for overhead connections made of bare wires and insulated ones as well as for the cable connections. Failure statistics of these connections for the 10 years operation period of the network were considered. Causes of the failures and the seasonal variation of the damage frequency were presented. The recovery duration, the duration of electricity supply interruptions and the value of undelivered electricity to customers as a result of the failures were analysed. The empirical models and attempt to identify the theoretical model of probability density of considered parameters were presented as well. Indicators of reliability of connections for power supply were calculated.
PL
W artykule przedstawiono wyniki oceny podstawowych funkcji określających właściwości niezawodnościowe przyłączy nN, jakimi są funkcja intensywności awarii, funkcja niezawodności oraz funkcja zawodności. Na podstawie wieloletnich obserwacji przyłączy nN eksploatowanych w sieci dużej spółki dystrybucyjnej energii elektrycznej w kraju, określono przebiegi empiryczne wymienionych funkcji. Przeprowadzono także analizę zgodności rozkładu empirycznego z założonym rozkładem teoretycznym. Wyznaczono wartość oczekiwaną czasu poprawnej pracy przyłączy nN do chwili powstania uszkodzenia.
EN
The paper presents the results of the evaluation of basic functions determining reliability characteristics of LV connections, i.e. their failure intensity function, function of reliability and unreliability function. On the basis of long-term monitoring of LV connections that operate in a large electricity distribution company in Poland, the empirical waveforms of mentioned features have been defined. An accordance of these empirical distributions with the assumed theoretical ones has been also investigated. The expected values of the lifetime to damage of the LV connections have been determined as well.
6
Content available remote Analiza awaryjności przewodów sieci wodociągowej w Kielcach
PL
W artykule przedstawiono zmiany awaryjności przewodów sieci wodociągowej w Kielcach. Analizę awaryjności przeprowadzono w grupach przewodów wydzielonych ze względu na funkcję przewodu, materiał rur oraz długość okresu ich eksploatacji. Ponadto w artykule wskazano na główne przyczyny awarii przewodów zaobserwowane na terenie Kielc w ostatnich 5 latach oraz ich skutki.
EN
The paper presents the changes in water pipe failure frequency observed in Kielce water supply system. The analysis of failure frequency was conducted in groups of pipes depending on the function of a pipe in Kielce water supply system, material of a pipe and time of its exploitation. The paper also shows the basic reasons for failures observed in the last 5 years in Kielce water supply system and their consequences.
PL
W artykule przedstawiona została analiza podstawowych funkcji charakteryzujących właściwości niezawodnościowe elektroenergetycznych stacji napowietrznych oraz wnętrzowych SN/nN, jakimi są funkcja intensywności awarii, funkcja niezawodności oraz funkcja zawodności. Na podstawie wieloletnich obserwacji stacji SN/nN eksploatowanych na terenie dużego zakładu energetycznego w kraju określone zostały przebiegi empiryczne wymienionych funkcji. Podjęta została także próba dopasowania funkcji teoretycznych do zaprezentowanych funkcji empirycznych.
EN
The paper presents an analysis of the basic functions characterizing the properties of reliability of indoor power stations and overhead pole stations, such as failure intensity function, reliability function and unreliability function. On the basis of observations of MV / LV stations operated in a large power company in the country were determined empirical courses listed functions. Was also taken an attempt to fit theoretical distributions to empirical functions presented.
PL
Praca poświęcona jest problemom niezawodności systemów po usunięciu defektu i wznowieniu działania. Zaproponowano procedurę postępowania przy określaniu indeksu niezawodności systemów wznowionych przy zastosowaniu modelu Markowa. Rozważania teoretyczne zilustrowano przykładem modelu systemu zawierającego dwa składniki.
EN
The paper is devoted to problem of failure intensity determination for renewal systems. The rules for failure intensity determination using Markov reliability model is suggested. The example for reliability model of two component renewal non-redundancy system with instantaneous repairs duration is given. The correctness of such reliability model is proved by verifying methods.