Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  intensity of radiation
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper investigates the effect of background radiation on the accuracy of temperature measurement by infrared radiation and defines the requirements to neglect multiple reflections of radiation. The theoretical analysis is confirmed by the results of modeling the temperature measurement radiation errors.
PL
W artykule przeprowadzono analizę wpływu promieniowania tła na dokładność pomiaru temperatury promieniowaniem podczerwonym. Zdefiniowano wymagania dotyczące możliwości pominięcia wielokrotnych odbić promieniowania. Analizę teoretyczną potwierdzono wynikami modelowania błędów radiacyjnych pomiaru temperatury.
PL
W pracy zaprezentowano wpływ zaćmienia słonecznego z dnia 20.03.2015 na zmiany mocy oraz energii elektrycznej produkowanej przez system fotowoltaiczny w porównaniu do bezchmurnego dnia 17.03.2015 oraz do dnia 20.03.2014. System fotowoltaiczny wykorzystuje moduły z krzemu monokrystalicznego oraz inwerter solarny Soladin 600 podłączony do uczelnianej sieci elektrycznej. Moc szczytowa systemu wynosi 330W. Instalacja pracuje w Rzeszowie (φ=50°02’N λ=22°17’E). Moduły fotowoltaiczne zamontowane są na ramie pod stałym kątem 30° względem horyzontu (poziomu). Układ pomiarowy systemu fotowoltaicznego obejmował pomiar napięcia oraz prądu DC przed inwerterem, napięcia, prądu AC, mocy oraz częstotliwości na wyjściu inwertera. Zaprezentowano również pomiary całkowitego i bezpośredniego natężenia promieniowania słonecznego oraz promieniowanie rozproszone w dniu zaćmienia Słońca 20.03.2015 oraz w dniach 17.03.2015 i 20.03.2014 padające na płaszczyznę poziomą. Wszystkie parametry były mierzone co 10 sekund i uśredniane do 1 minutowych wartości. Dokonano również obserwacji wizualnych tarczy Słońca przy wykorzystaniu aparatu fotograficznego DSLR SONY A-57 oraz teleskopu typu Maksutow-Cassegrain o ogniskowej f=1500mm, oraz aperturze 127mm. Światłosiła teleskopu wynosi F 1:11,8. Zestaw zamontowany był na montażu paralaktycznym HEQ-5 SynScan. Wyniki badań ukazują, że podczas maksimum zaćmienia Słońca w Rzeszowie, które wystąpiło o godzinie 10:56 chwilowa moc systemu fotowoltaicznego zmalała o 60%, natomiast dobowa energia elektryczna zmalała o -13,4% w stosunku do niezachmurzonego dnia.
EN
The paper presents the impact of solar eclipse of 20.03.2015 on power and electricity produced changes by the PV system compared to the cloudless day 03.17.2015 and on 20.03.2014. The system uses photovoltaic monocrystalline silicon modules and solar inverter Soladin 600 connected to the electricity grid. Peak power system is 330W. Installation works in Rzeszow (φ = 50°02'N λ = 22°17'E). PV modules are mounted on the frame at a constant angle of 30° relative to the horizon. The measuring system comprised the measurement of voltage and DC current before an inverter, voltage, AC current, power and frequency at the output of the inverter. Also presented measurements of total and direct solar radiation and the scattered radiation in the day of a solar eclipse 03.20.2015 and on 03.17.2015 and 20.03.2014 falling on a horizontal plane. All parameters were measured every 10 seconds and averaged to 1 minute values. Also made visual observations of the sun using a camera Sony DSLR A-57 and Maksutov-Cassegrain telescope with a focal length f = 1500mm, 127mm aperture. Maximum aperture telescope is F 1: 11.8. Set was mounted on an equatorial mount HEQ-5 SynScan. The results show that the maximum eclipse in Rzeszow, which occurred at 10:56 instantaneous power photovoltaic system decreased by 60%, while the daily electricity decreased by -13.4% compared to cloudless day.
EN
The effective heating systems of high industial premises are systems based on the use of electric infrared heaters. The main advantage of them is that they heat only the areas where heating is required. The purpose of the publication was development of research setting based on the infrared heater for the study of the intensity of radiation surfaces, which was designed the graphics dependence on the results of study. The results of experimental studies were done concerning the determination of the intensity of radiation surface by the infrared heaters depending on the power and height of their installation. The researches of the radiation intensity of the infrared heater in non-rotary work mode have been done. The distribution of intensity of radiation by the infrared heater in its rotary and non-rotary work modes was shown.
PL
Efektywnymi systemami ogrzewania wysokich pomieszczeń w budynkach przemysłowych są systemy oparte na zastosowaniu elektrycznych promienników podczerwieni. Główną ich zaletą jest to, że ogrzewa się tylko te obszary, których ogrzewanie jest wymagane. Celem badań było poszerzenie wiedzy o promiennikach podczerwieni odnośnie natężenia ich promieniowania. Rezultatem badań było opracowanie zależności graficznych. Przedstawiono wpływ wysokości zamontowania oraz mocy promiennika na natężenie jego promieniowania na daną powierzchnię. Badania te przeprowadzono dla promienników stacjonarnych bez możliwości obrotu. Zaprezentowano również rozkład natężenia promieniowania stacjonarnego promiennika podczerwieni oraz promiennika pracującego w trybie obrotowym.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.