Precise current measurements are essential part of modern motor control algorithms. They are also required in switch mode power converters, safety circuits, current sources, supervisor systems and many other applications. In order to select the right method, it is often required from the designer to have wide knowledge of the appropriate integrated circuit, its parameters and applications. Still increasing requirements for the speed and precision of designing solutions, decreasing voltage levels, power consumption and aspects of EMC compatibility impose often contrary initial conditions.
PL
Precyzyjne pomiary prądu są zasadniczą częścią nowoczesnych algorytmów sterowania silnikami. Są także stosowane w przetwornicach mocy, obwodach bezpieczeństwa, źródłach prądowych, systemach nadzoru i wielu innych aplikacjach. W celu wybrania właściwej metody projektant musi mieć szeroką wiedzę na temat odpowiedniego obwodu scalonego, jego parametrów i aplikacji. Rosnące wymagania dotyczące szybkości i precyzji projektowanych rozwiązań, obniżenie poziomów napięć, zużycie energii oraz aspekty kompatybilności elektromagnetycznej powodują często sprzeczne warunki początkowe.
EN
In this paper a programmable input mode instrumentation amplifier (IA) utilising second generation, multiple output current conveyors and transmission gates is presented. Its main advantage is the ability to choose a voltage or current mode of inputs by setting the voltage of two configuration nodes. The presented IA is prepared as an integrated circuit block to be used alone or as a sub-block in a microcontroller or in a field programmable gate array (FPGA), which shall condition analogue signals to be next converted by an analogue-to-digital converter (ADC). IA is designed in AMS 0.35 µm CMOS technology and the power supply is 3.3 V; the power consumption is approximately 9.1 mW. A linear input range in the voltage mode reaches ± 1.68 V or ± 250 µA in current mode. A passband of the IA is above 11 MHz. The amplifier works in class A, so its current supply is almost constant and does not cause noise disturbing nearby working precision analogue circuits.
EN
This paper deals with design of readout circuit dedicated for NMOS-based terahertz detectors. The proposed architecture bases on chopper amplifier and instrumentation amplifier concepts. The main objectives were high gain (max. 100 dB) and proper operation with NMOS-based THz detectors. Three different architectures of measurement amplifier designed for the research project are discussed in this paper. The designed chip was manufactured in AMS C35B4 process (350 nm feature size). Another issue described in this paper is dedicated, non-typical testing environment. At the end a few measurement results are shown.
EN
This paper introduces a low-noise, low-power amplifier for high-impedance sensors. An innovative circuit using an auto-zeroed architecture combined with frequency modulation to reject offset and low-frequency noise is proposed and analysed. Special care was given to avoid broadband noise aliasing and chopping in the signal path, and to minimize both the resulting equivalent input offset voltage and equivalent input biasing current. The theoretical noise analysis of the proposed topology covers most of the noise sources of the circuit. Simulations show that the input-referred noise level of the circuit is 13.4nV/√Hz for a power consumption of 85µA with a power supply from 1.8V to 3.6V.
PL
W artykule zaprezentowano nową koncepcję układu rejestracji sygnałów bioelektrycznych. W prezentowanym systemie akwizycji sygnałów wykorzystano nowy, programowalny uniwersalny moduł przetwarzania ADS1298 firmy Texas Instruments zawierający wejściowe multipleksery, wzmacniacze o programowanym wzmocnieniu, 24 bitowe przetworniki A/C i układ interfejsu szeregowego. Prezentowany system umożliwia rejestrację sygnałów wraz ze składową stałą, co pozwoliło na wyeliminowanie powszechnie stosowanych filtrów górno-przepustowych o dużych stałych czasowych. Prezentowany moduł może znaleźć zastosowanie w aplikacjach biomedycznych do rejestracji różnorodnych sygnałów bioelektrycznych np. sygnału elektrokardiograficznego (EKG), elektrogastrograficznego (EGG) czy sygnału elektroencefalograficznego (EEG).
EN
In this paper a new application of the universal programmable ECG front-end module ADS1298 is presented. To avoid amplification of the input signal dc component in standard biomedical amplifiers after the first stage, an analog high-pass filter is used. Hardware high-pass filters are difficult to change their corner frequency (time constant) and a step change of the dc offset voltage gives a long transient response. This long response saturates the next amplifier and causes decay of the signal for a certain time. Analysis of such a case, given in this work, allows estimating the dead time as a function of some amplifier parameters like distribution of the amplifier gain before and after the high-pass filter, the filter time constant, supply voltages of the first amplifier , the input signal range of an A/D converter and the zoom factor p used in a visuali-zation system. Thanks to the 24-bits resolution of the A/D converter and programmable gain input amplifiers, a biomedical signal can be recorded with its offset, which allows eliminating hardware high-pass filters. High-pass filtering is realised by software, which allows building more flexible systems using the same analog front-end. The proposed solution was tested on simulated signals form generators, ECG phantom and 12 leads ECG signal with good results. It allows constructing portable, universal biomedical recording systems such as 12 leads ECG systems, Holter recorders, EEG recorders EEG recorders, tuned only by software.
PL
W artykule przedstawiono interaktywny system sterowania pracą laboratoryjnej suwnicy pomostowej natorowej wykorzystujący wzmacniacz pomiarowy firmy Hottinger Baldwin Messtechnik Spider8. Do sterowania pracą elektronapędów z przemiennikami częstotliwości wykorzystano wejścia i wyjścia cyfrowe wzmacniacza, natomiast wejścia analogowe wykorzystano do monitorowania wybranych obciążeń suwnicy pomostowej natorowej. Do wizualizacji, rejestracji wielkości mierzonych oraz sterowania i demonstracji stanu elektronapędów suwnicy pomostowej wykorzystano program Catman.
EN
The paper presents an interactive system for controlling the operation of the laboratory bridge crane using a measurement amplifier of the Hottinger Baldwin Messtechnik Company - SPIDER8. To control the operation of electric drives with frequency converters digital input and output of this amplifier were used. Analog inputs were used to monitor selected loads of bridge crane. For visualization, registration and control of the measured values as well as demonstration of the electric drive of bridge crane the Catman program was used.
PL
W artykule zaprezentowano nową koncepcję układu do rejestracji sygnałów bioelektrycznych polegającą na zastosowaniu wzmacniacza prądu stałego i 24 bitowego przetwornika A/C. W zbudowanym systemie wykorzystano nowy układ ADS1298 firmy Texas Instruments, zawierający 8 torów pomiarowych. Przedstawiony system umożliwia wielokanałową rejestrację sygnałów wraz ze składową stałą. Pozwoliło to na wyeliminowanie, powszechnie dotąd stosowanych, filtrów górno-przepustowych o dużych stałych czasowych i zastąpienie ich filtrami cyfrowymi.
EN
The new concept of biomedical recording device using DC-coupled amplifier and 24 bit A/D converter is presented. Using recently launched front-end module ADS1298 from Texas-Instruments 8 channels system was designed. Thanks to 24–bits resolution of A/D converter and programmable gain input amplifiers, biomedical signals can be recorded with offsets, that allows to eliminate hardware high-pass filters.
PL
Przedstawiono prototypowy układ akwizycji sygnałów EEG, przeznaczony do prowadzenia badań naukowych w zakresie rozwoju metod analizy sygnału EEG do zastosowań w interfejsach BCI (brain-computer interface). Układ umożliwia cyfrową rejestrację sygnałów w ośmiu kanałach przy poziomie zakłóceń typowego pomieszczenia laboratoryjnego i jest izolowany galwanicznie od urządzeń współpracujących (np. komputera). Omówiono schemat blokowy skonstruowanego układu i obwody kompensacji zakłóceń.
EN
The aim of this work to design a multi-channel mixed-signal system for EEG signal asquisition in brain-computer interfaces. The paper contains a review of EEG signal analysis methods that are used in human-computer communication systems. Selected systems of this type are described in more detail. A prototype, single-channel sub-system architecture is characterized featuring sufficiently high noise immunity and commonmode rejection to allow EEG signal acquisition. Optical isolation is used for safe circuit operation in a typical office environment.